Model: OCA-3

Ratio: 50–3000/5 A or /1 A (standard ranges)Accuracy Classes: 0.2S / 0.5S / 1 / 3 (measurement); 5P / 10P (protection)Burden: 2.5–30 VAInsulation Voltage: 0.72 kV (LV), up to 36 kV (MV)
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

OCA-3 — ABB Current Transformer (Measurement Class)

ABB current transformers for measurement and metering applications are precision electromagnetic devices manufactured to IEC 61869-2 (superseding IEC 60044-1), providing accurate current signal reproduction for energy meters, power analyzers, power quality instruments, and protection relays in LV and MV electrical systems. The OCA series covers bar-primary single-turn CTs for LV panels from 50/5 A up to 3000/5 A in compact ring-core formats suitable for DIN rail or busbar mounting, while the OCD wound primary series covers lower current ratios from 5/5 A upward. ABB offers accuracy classes 0.2S, 0.5S, 1, 3, and 5 for measurement, and 5P, 10P, and PX for protection functions, across burdens from 2.5 VA to 30 VA — enabling engineers to select precisely the class and burden combination required for each application without overspecifying.

Class 0.2S is the critical distinction for billing-grade metering in Saudi Arabia. The Saudi Electricity Company (SEC) requires Class 0.2S current transformers at all industrial and commercial supply points where active energy billing is based on measured kWh, and ARAMCO's SAES-P-119 electrical metering standard mandates 0.2S CTs for all fiscal metering points. The 'S' suffix indicates the CT maintains its 0.2% accuracy down to 1% of rated current — five times the dynamic range of a standard 0.2 class CT — ensuring accurate measurement even when the supply is lightly loaded at night or during shutdowns. Split-core CTs (the OCS series) allow retrofit installation around existing busbars or cables without disconnecting the circuit, enabling energy metering upgrades without planned power outages — an increasingly important feature as Saudi Arabian facility managers install power quality monitoring systems across legacy distribution infrastructure.

In Saudi Arabia, ABB measurement CTs are specified across every sector from utility grid connection metering to sub-metering in commercial developments to fiscal custody transfer metering in oil and gas. ARAMCO's SAES-P-119 approved CT list includes ABB OCA and OCD series; SEC's T&D approved vendor list includes ABB CTs for utility revenue metering; MARAFIQ specifies ABB 0.2S CTs for its utility interface metering points at Jubail Industrial City. Vision 2030 smart city projects including NEOM's building energy management infrastructure use ABB Class 0.5S CTs feeding sub-metering systems for tenant billing and sustainability reporting. The OCS split-core series is the preferred CT for energy audit contractors performing IEC 62053-based energy surveys across Saudi Arabia's commercial building stock.

Razz Middle East supplies ABB measurement CTs in all standard ratios from 50/5 A to 3000/5 A, all accuracy classes from 0.2S to 5, and all mounting formats (bar-primary ring, wound primary, split-core) for immediate delivery across Saudi Arabia. We provide CT selection support for energy metering system designs, SEC billing class compliance verification, and full calibration certificates traceable to national metrological standards.

Technical Specifications

Full specifications for the OCA-3

Ratio
50–3000/5 A or /1 A (standard ranges)
Accuracy Classes
0.2S / 0.5S / 1 / 3 (measurement); 5P / 10P (protection)
Burden
2.5–30 VA
Insulation Voltage
0.72 kV (LV), up to 36 kV (MV)
Mounting
Bar-primary ring / Wound primary / Split-core
Frequency
50 Hz / 60 Hz
Ambient Temperature
-5 to +40°C
Thermal Rating
120 In (1s) continuous 1.2 In
Standard
IEC 61869-2
Certification
CE, SASO

Key Features & Benefits

  • Accuracy class 0.2S maintains ±0.2% current ratio error down to 1% of rated current (6× the dynamic range of standard 0.2 class), satisfying SEC SASO and Saudi Aramco SAES-P-119 billing-grade metering requirements at lightly loaded supply points.
  • Split-core OCS series installs around existing busbars and cables without disconnecting the circuit, enabling energy metering retrofits on live distribution systems without planned power outages — critical for metering upgrades on occupied commercial buildings.
  • Single-ratio and multi-ratio tapped secondary options (e.g., 600-300/5 A) provide operational flexibility for installations where future load growth may require a different CT ratio without CT replacement.
  • Class 5P and 10P protection accuracy class variants are available in the same physical CT body, allowing a dual-ratio, dual-secondary CT to serve both billing metering (0.2S secondary) and protection relaying (5P secondary) from a single installation.
  • Bar-primary ring core OCA series rated up to 3000/5 A at 0.72 kV LV covers the highest current ratings at MCC and main distribution busbar positions without requiring wound primary construction, reducing physical size and cost.
  • IEC 61869-2 polarity marking and terminal identification ensures correct connection to energy meters and protection relays, preventing metering errors from reversed CT polarity — a common commissioning fault on complex multi-feeder panels.
  • Low burden designs (2.5 VA and 5 VA) reduce CT magnetising current contribution to metering error, enabling higher accuracy at lower cost compared to higher burden CTs requiring larger cables and longer wiring runs.

Industrial Applications in Saudi Arabia

  • SEC utility billing metering at industrial and commercial supply points across Saudi Arabia, where Class 0.2S CTs certified to IEC 61869-2 are mandatory for revenue-grade kWh measurement under Saudi Electricity Company tariff regulations.
  • Saudi Aramco fiscal custody transfer metering at wellhead, pipeline, and refinery supply points, where SAES-P-119 mandates 0.2S accuracy class CTs with calibration certificates traceable to SASO national measurement standards.
  • Power quality monitoring and harmonic analysis instrumentation at SABIC and MARAFIQ industrial facilities, where Class 0.5S CTs over the full dynamic range ensure accurate harmonic current spectrum measurement for IEC 61000-3-12 compliance reporting.
  • Tenant sub-metering in commercial towers and business parks across Riyadh and Jeddah, where Class 1 split-core CTs enable energy management system installation on existing tenant distribution circuits without tenant power interruption.
  • Protection relay current sensing at MV switchgear and LV main distribution panels, where Class 5P and 10P CTs with defined accuracy limit factors ensure protection relay operation under maximum fault current conditions.
  • NEOM and Red Sea Project building energy management sub-metering infrastructure, where ABB Class 0.5S CTs connected to smart energy meters provide the granular consumption data required for sustainability certification and tenant billing platforms.
  • Retrofit energy auditing surveys by SEC-approved energy audit firms across Saudi Arabia's commercial building stock, where OCS split-core CTs allow temporary or permanent installation on existing circuits for IEC 62053 compliant energy data collection.