ABB DOL Motor Starter Kit (AF + T Series) — DOL-KIT-AF09

abb

ABB DOL Motor Starter Kit (AF + T Series)

Model: DOL-KIT-AF09

Contactor: AF Series (AF09–AF65)Motor Range: 0.25–45 kW at 400 VOverload Relay: T-series (matched current range)Coordination: Type 2 (IEC 60947-4-1)
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

DOL-KIT-AF09 — ABB DOL Motor Starter Kit (AF + T Series)

ABB direct-on-line (DOL) motor starter kits combine a factory-selected and pre-coordinated AF series electronically actuated contactor with a T series thermal overload relay and all necessary DIN rail accessories into a single part number, delivering a Type 2 IEC 60947-4-1 coordinated motor starting assembly that panel builders can order, receive, and assemble without separate component selection work. The kit format covers motor powers from 0.25 kW to 45 kW at 400 V across the AF09-to-AF65 contactor range, with the T-series overload relay current range matched to the exact motor power selected. Coil voltage options of 24 V DC, 110 V AC, and 220 V AC are available to match every standard Saudi Arabian control circuit voltage, and accessories including auxiliary contact blocks, mechanical interlock frames, and mounting rails are included where required for the selected starting duty.

The AF series contactor at the heart of the DOL kit introduces a significant advance over conventional coil-wound contactors: the AF contactor's electronic actuator accepts any voltage between 24 and 500 V AC/DC simultaneously without coil or coil resistance changes, making it genuinely power-supply agnostic. Once energised, the AF contactor's hold current drops to 5–10% of its pull-in current due to the electronic actuator's adaptive hold feature, reducing control circuit power consumption by 80–90% compared to conventional contactors — a meaningful energy saving across the thousands of motor starters running continuously in Saudi Arabia's pump, HVAC, and process facilities. The AF contactor's electronic surge suppression eliminates the need for external RC snubber circuits across contactor coil terminals that are routinely fitted to protect PLC output modules on conventional contactor installations.

DOL starters are the most common motor starting solution in Saudi Arabia's industrial and commercial sectors by sheer number of installations — every fan, pump, and conveyor motor that does not justify a variable speed drive or soft starter uses a DOL starter as its primary starting and protection element. ARAMCO, SABIC, NWC, and SEC all have standard motor control center designs that specify ABB AF+T DOL starter assemblies for their MCC outgoing motor feeder modules. Panel builders in Riyadh's Al-Malaz industrial zone, Jeddah's southern industrial area, and Dammam's industrial city assemble MCC panels with ABB DOL kits as their default motor starter component. The Type 2 coordination documentation provided with each kit satisfies the project engineer's requirement to demonstrate that the contactor and overload relay combination has been tested to IEC 60947-4-1 for fault condition performance without endangering personnel.

Razz Middle East maintains stock of ABB DOL starter kits from AF09 (0.25–4 kW) through AF65 (18.5–45 kW) in 24 V DC and 220 V AC coil versions, with complete Type 2 coordination tables and IEC 60947-4-1 test certificates included with every kit. We supply single kits for maintenance and bulk packs for panel builders, with same-day dispatch and SAR pricing.

Technical Specifications

Full specifications for the DOL-KIT-AF09

Contactor
AF Series (AF09–AF65)
Motor Range
0.25–45 kW at 400 V
Overload Relay
T-series (matched current range)
Coordination
Type 2 (IEC 60947-4-1)
Coil Voltage
24 V DC / 110 V AC / 220 V AC
AF Contactor Supply
24–500 V AC/DC universal (AF series)
Hold Current
5–10% of pull-in (electronic actuator)
Mounting
DIN rail or direct panel
Documentation
Type 2 coordination tables + IEC 60947-4-1
Included
Contactor, overload relay, fixing accessories

Key Features & Benefits

  • Factory-selected Type 2 coordinated contactor and overload relay combination tested to IEC 60947-4-1 ensures the assembly performs correctly under fault conditions without requiring the panel builder to perform their own coordination selection or testing.
  • AF series electronic actuator accepts 24–500 V AC/DC simultaneously, making the DOL kit coil-voltage independent within this range and eliminating the need to stock different contactor part numbers for 110 V AC and 220 V AC control circuits.
  • Electronic actuator hold current reduction to 5–10% of pull-in current saves 80–90% of contactor coil power versus conventional wound coil contactors — significant energy saving across thousands of continuously energised motor starters in Saudi facilities.
  • Built-in surge suppression on AF contactor electronic actuator eliminates the need for external RC snubber circuits across contactor coil terminals, simplifying panel wiring and protecting PLC digital output modules from inductive back-EMF damage.
  • T-series overload relay direct clip-on mounting to AF contactor body without wiring creates a compact, pre-wired assembly that reduces panel width and eliminates wiring errors between contactor and overload relay terminals.
  • Phase-failure sensitive T-series overload relay detects single-phasing during DOL operation even at partial motor loads, protecting motors from the silent single-phasing failures that cause 30–40% of induction motor burnouts in Saudi Arabian industrial sites.
  • Complete documentation package including Type 2 coordination tables and IEC 60947-4-1 test certificates satisfies ARAMCO, SABIC, and SEC project engineer requirements without additional calculations or test reports from the panel builder.

Industrial Applications in Saudi Arabia

  • MCC outgoing motor feeder modules for pump, fan, and conveyor motors at ARAMCO GOSPs, SABIC petrochemical plants, and SEC substations, where ABB DOL kits are the standard specified starter assembly in the motor control center design standard.
  • HVAC fan and chilled water pump starters in commercial buildings across Riyadh, Jeddah, and the Eastern Province, where the AF electronic actuator's low hold current reduces MCC panel heat load in building electrical rooms.
  • Water pump motor starters at NWC booster stations and municipal water treatment plants, where AF+T DOL kits provide proven Type 2 protection coordination required by the National Water Company's electrical panel standards.
  • Industrial process motor starters at MODON industrial estates and manufacturing facilities, where DOL kits from AF09 to AF65 cover every motor from small fractional-kW agitators to 45 kW main drive motors.
  • Agricultural and irrigation pump starters across Saudi Arabia's agricultural regions, where the AF contactor's universal coil voltage eliminates field problems caused by supply voltage variation between 200 V and 500 V AC on rural distribution feeders.
  • Conveyor and material handling motor starters at port logistics facilities (King Abdulaziz Port, Jeddah Islamic Port), where DOL starters' simplicity and AF contactor reliability reduce maintenance requirements on high-cycle start-stop applications.
  • Building services equipment starters including elevator machine room pumps, car park ventilation fans, and fire pump jockey sets, where Type 2 coordination documentation is required for building permit and SEC connection approval submissions.

Industrial Supplier in Saudi Arabia

Get a Quote for the ABB DOL Motor Starter Kit (AF + T Series)

We respond within 4 business hours. Send model DOL-KIT-AF09 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — DOL-KIT-AF09

Common questions from buyers in Saudi Arabia and the GCC