ABB OT200 Main Switch Disconnector — OT200U03P

abb

ABB OT200 Main Switch Disconnector

Model: OT200U03P

Rated Current: 200 AVoltage: Up to 1000 V AC / 250 V DCUtilization Category: AC-23APoles: 3P / 4P
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

OT200U03P — ABB OT200 Main Switch Disconnector

The ABB OT200 is a heavy-duty switch-disconnector rated at 200 A AC-23A for use as the main incoming isolation switch in distribution boards, motor control centers, machine panels, and industrial enclosures. Built to IEC 60947-3, the OT200 provides full load-breaking capability — it can make and break at full 200 A rated load, unlike a pure isolator — and the through-door operating mechanism allows safe switching with the panel door closed, a fundamental safety requirement under Saudi Arabia's electrical safety regulations and ARAMCO's SAES-B-068 safety standards. The three-padlock capability on the off-position handle satisfies LOTO (lockout-tagout) requirements mandated on all ARAMCO, SABIC, and SEC sites, allowing multiple maintenance trades to simultaneously lock out a circuit they are working on.

Technically, the OT200 covers supply voltages up to 1000 V AC and 250 V DC, making it suitable not only for standard 400 V LV distribution but also for 690 V industrial drives and DC battery and UPS systems. Its AC-23A utilization category (switching motor loads and mixed inductive loads) ensures reliable operation across the varied load types found in industrial panels, avoiding contact erosion failures that occur when lower-category switches are misapplied. The transparent window on the front cover provides visual confirmation of the main contact position — open or closed — without opening the panel door, meeting IEC 60947-3 visible isolation requirements that are increasingly enforced in SEC and ARAMCO facility audits. Auxiliary contacts, shunt trip coil, and undervoltage release accessories are available for remote switching, automatic shutdown on fault, and supervision within BMS or SCADA systems.

In Saudi Arabia, the OT200 is the de facto standard main switch in every category of LV panel from small machine control enclosures to large 2500 A main distribution boards (where multiple OT200 units serve as feeder isolation switches). Panel builders across Riyadh's MODON industrial zones, Jeddah's commercial tower electrical rooms, and Jubail's petrochemical facility MCRs assemble thousands of OT200 switches annually. The OT200 is listed in ABB's SASO-approved products register for Saudi Arabia, satisfying the documentation requirements of SASO-IEC 60947-3 for electrical products sold in the Kingdom. Door-coupling kits for panel door mounting are available in rotary handle and padlockable versions to match all standard IEC panel door thicknesses from 1.5 mm to 4 mm.

Razz Middle East holds OT200 in three-pole and four-pole versions with a complete range of door-coupling kits, auxiliary contact blocks, and shunt trip coils in our in-kingdom warehouse. We supply single units for maintenance replacement and bulk quantities for panel builders, with same-day dispatch for urgent requirements and SAR pricing on all order sizes.

Technical Specifications

Full specifications for the OT200U03P

Rated Current
200 A
Voltage
Up to 1000 V AC / 250 V DC
Utilization Category
AC-23A
Poles
3P / 4P
Padlocking
3 padlocks in OFF position
Door Coupling
Through-door drive mechanism
Auxiliary Contacts
2NO+2NC snap-on
Shunt Trip
Available (24–240 V AC/DC)
Window
Transparent position indicator
Standard
IEC 60947-3

Key Features & Benefits

  • Full AC-23A load-breaking capability at 200 A allows safe switching of motor loads and mixed inductive circuits, unlike pure isolators that can only switch under no-load conditions — critical for ARAMCO SAES-B-068 and SEC safe isolation procedures.
  • Three-padlock facility on the off-position handle satisfies LOTO requirements on all ARAMCO, SABIC, and SEC sites, allowing multiple maintenance teams to simultaneously lock out and tag out circuits they are working on independently.
  • Transparent front window provides visual confirmation of contact position (open/closed) without opening the panel door, meeting IEC 60947-3 visible isolation requirements and reducing arc flash exposure during routine operational checks.
  • Through-door rotary mechanism enables switching with the panel door closed, eliminating operator exposure to energised components during routine switching operations — a fundamental requirement of Saudi Arabia's electrical safety regulations.
  • Rated to 1000 V AC and 250 V DC in a single device covers standard 400 V LV, 690 V industrial supply, and DC battery/UPS systems, simplifying component standardisation across diverse panel types.
  • Snap-on shunt trip coil and undervoltage release accessories enable remote switching, automatic shutdown on supply fault, and BMS/SCADA supervision without additional external relays or wiring components.
  • SASO-approved product per SASO-IEC 60947-3, satisfying the Saudi Standards Authority product conformity requirements for electrical switching devices sold and installed in the Kingdom.

Industrial Applications in Saudi Arabia

  • Main incoming isolation switch in LV distribution boards at commercial buildings and industrial facilities across Saudi Arabia, where AC-23A load-breaking capability and padlocking meet ARAMCO SAES-B-068 and IEC 60364 safe isolation requirements.
  • Machine tool and industrial equipment main power switch in compliance with IEC 60204-1 machinery safety standard, which mandates a main switch with lockable off position, visible position indicator, and full load-breaking capability.
  • Motor control center incoming switch in SABIC and ARAMCO plant MCRs, where the three-padlock LOTO capability and shunt trip option for emergency shutdown satisfy the site's specific permit-to-work electrical safety procedures.
  • Generator and UPS panel main disconnect switch in critical facility power systems including hospitals, airports, and data centres, where the 1000 V AC rating and load-breaking capability cover both normal and emergency supply connections.
  • Switchboard outgoing feeder isolation switches at substations and distribution boards across MODON industrial estates, where multiple OT200 units provide individually lockable feeder isolation for safe maintenance without total board shutdown.
  • Agricultural and water pump station main switches in remote locations across Saudi Arabia, where the IP65-rated enclosure version and padlocking capability provide weather-resistant isolation and security for unstaffed sites.
  • Renewable energy inverter disconnect switches in commercial solar installations, where the OT200's 1000 V AC rating covers inverter AC output and the padlocking facility meets NEC 690 and IEC 62109 inverter isolation requirements.

Industrial Supplier in Saudi Arabia

Get a Quote for the ABB OT200 Main Switch Disconnector

We respond within 4 business hours. Send model OT200U03P for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — OT200U03P

Common questions from buyers in Saudi Arabia and the GCC