ABB S800 Industrial Miniature Circuit Breaker — S804B-C100

abb

ABB S800 Industrial Miniature Circuit Breaker

Model: S804B-C100

Rated Current: 25–125 AVoltage: 400/415 V AC (S800PV: up to 1500 V DC)Breaking Capacity: Up to 50 kA (S803B) at 400 VTrip Characteristics: B / C / D
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

S804B-C100 — ABB S800 Industrial Miniature Circuit Breaker

The ABB S800 Industrial Miniature Circuit Breaker is ABB's heavy-duty DIN-rail MCB range, engineered to bridge the gap between standard 6 kA residential MCBs and full MCCBs in industrial panel applications requiring up to 125 A and breaking capacities up to 50 kA. The S800 series covers rated currents from 25 A to 125 A in 1P, 2P, 3P, and 4P configurations, with trip curve options B (2–3× In), C (5–10× In), and D (10–20× In) covering everything from capacitor switching to motor protection to highly inductive welding equipment circuits. Its compact DIN-rail footprint — three modules wide per pole — fits in standard industrial distribution panels without the space penalty of a full MCCB, while the 50 kA breaking capacity (S803B model) satisfies the fault level requirements at secondary and tertiary distribution points in most Saudi Arabian industrial facilities.

The S800 technical design prioritises reliability and accessory integration. The front-mounted auxiliary contact block, shunt trip release, and undervoltage release snap directly onto the MCB body without tools, enabling remote tripping and supervision functions essential for motor control center and fire safety panel applications. An S800PV variant with DC-rated breaking capability to 1500 V serves the solar photovoltaic string protection market, which is growing rapidly in Saudi Arabia's commercial solar sector. The S800-SC (selectivity coordinator) allows parallel operation of S800 MCBs at high fault currents without nuisance tripping of upstream devices, a feature increasingly required in Saudi Arabia's compact industrial panels where traditional selectivity margins cannot always be maintained.

The S800 Saudi Arabia is the standard industrial feeder MCB in motor control centers, distribution boards, and machine panels throughout the Kingdom. ARAMCO plant electrical standards specify S800 MCBs for feeder protection in MCC outgoing circuits up to 125 A, while SABIC and SEC project specifications routinely list the S800 as an approved device for industrial distribution. Machine builders in Riyadh and Jeddah use S800 MCBs for control power transformer secondary protection, where the D-curve characteristic handles the high inrush current of instrument transformers without requiring an oversized breaker. The S800PV variant is widely used in commercial solar installations across Saudi Arabia, where DC breaking capability up to 1500 V covers modern utility-scale string inverter configurations.

Razz Middle East maintains comprehensive S800 stock across all current ratings, trip curves, and pole configurations in our in-kingdom warehouse, enabling same-day availability for urgent projects. We carry all S800 accessories including auxiliary contacts, shunt releases, undervoltage releases, and motor drives, and provide full coordination studies to confirm S800 selectivity within your distribution system design.

Technical Specifications

Full specifications for the S804B-C100

Rated Current
25–125 A
Voltage
400/415 V AC (S800PV: up to 1500 V DC)
Breaking Capacity
Up to 50 kA (S803B) at 400 V
Trip Characteristics
B / C / D
Poles
1P / 2P / 3P / 4P
Width per Pole
3 DIN modules (27 mm)
Auxiliary Contacts
Snap-on (OF, SD, SDE)
Releases
Shunt trip, undervoltage (snap-on)
Standard
IEC 60898-2 / IEC 60947-2
PV Variant
S800PV up to 1500 V DC

Key Features & Benefits

  • Breaking capacity up to 50 kA at 400 V in a compact 3-module-per-pole DIN rail format, covering the fault levels at MCC feeder panels and sub-distribution boards in Saudi Arabia's industrial facilities without requiring a full MCCB.
  • D-curve trip characteristic (10–20× In) handles the high inrush currents of instrument transformers, control power transformers, and capacitor banks without nuisance tripping, enabling correct MCB sizing for these applications.
  • Snap-on auxiliary contact (OF), shunt trip, and undervoltage release accessories attach without tools directly to the MCB body, enabling remote tripping and circuit supervision for fire panel and BMS integration without additional wiring complexity.
  • S800PV DC-rated variant provides breaking capability up to 1500 V DC for solar photovoltaic string protection, covering modern utility-scale string inverter input voltage levels in Saudi Arabia's expanding commercial solar market.
  • S800-SC Selectivity Coordinator allows S800 MCBs to be used in cascaded panels at fault levels exceeding the individual MCB breaking capacity by using the downstream breaker's current limiting action, reducing installed MCCB count and panel cost.
  • Four-pole configuration with fully rated neutral pole (N) covers TN-S supply systems and generator-fed panels where neutral must be switched simultaneously with phases for safe isolation under IEC 60364 requirements.
  • Covers a wide range of industrial applications from standard feeder protection (C-curve) to motor starting protection (D-curve) to sensitive instrumentation and transformer protection (B-curve) within a single standardised platform.

Industrial Applications in Saudi Arabia

  • MCC outgoing feeder circuit protection in ARAMCO plant motor control centers, where S800 C-curve MCBs provide Type 2 coordination with AF-series contactors and T-series overload relays up to 45 kW motor circuits.
  • Control power transformer secondary protection in machine tool panels and process equipment across Saudi Arabia's industrial zones, where D-curve S800s withstand transformer energising inrush without tripping on current surges up to 20× rated.
  • Industrial distribution sub-panel incomer and feeder protection in SABIC petrochemical facilities and MARAFIQ utility substations, where the 50 kA breaking capacity covers available fault current at secondary distribution level.
  • Solar PV string and sub-array DC protection at commercial rooftop installations and industrial solar plants across the Kingdom, where S800PV provides 1500 V DC rated breaking to protect string inverter inputs.
  • Capacitor bank switching and protection in PFC panels at industrial facilities, where the C or D-curve S800 handles capacitor inrush transients that would cause nuisance tripping in standard residential MCBs.
  • Machine panel feeder and control circuit protection for packaging, food processing, and textile machinery OEMs building equipment for Saudi Arabian and GCC markets, where the compact format minimises panel cabinet size.
  • Generator and UPS output distribution panel MCBs in critical facilities including hospitals, data centres, and airports, where the 50 kA breaking capacity handles generator fault contribution in addition to utility fault current.

Industrial Supplier in Saudi Arabia

Get a Quote for the ABB S800 Industrial Miniature Circuit Breaker

We respond within 4 business hours. Send model S804B-C100 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — S804B-C100

Common questions from buyers in Saudi Arabia and the GCC