Model: CD10-65/220V

Standard: IEC 60947-4-1Poles: 3Rated Current (AC-3): 65 AMotor Power (AC-3, 400V): 30 kW
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

CD10-65/220V — Delixi CD10 65A AC Contactor 220VAC Coil

The Delixi CD10-65/220V is a 3-pole AC contactor rated at 65A (AC-3 duty) with a 220 VAC 50/60 Hz control coil, manufactured to IEC 60947-4-1 as a direct-equivalent alternative to the Schneider Electric TeSys D 65A contactor (LC1D65) that is widely specified in Saudi Arabia's industrial, HVAC, and heavy commercial sectors. At 65A / 30 kW (AC-3 duty at 400 V), this contactor handles the motor sizes that represent the boundary between commercial-scale and light industrial-scale HVAC and process equipment: primary supply fans in large air handling units, chiller compressor auxiliaries, large cooling tower fan drives, medium-size conveyor and process drives, and hydraulic power unit motors in industrial automation systems. The CD10-65/220V is particularly relevant to Saudi Arabia's industrial and petrochemical contractor market, where 30 kW motors are common in utility systems at refineries, petrochemical facilities, and manufacturing plants throughout the Kingdom.

In the context of the Saudi LV panel construction market, the 65A contactor marks the point at which starter assembly moves from DIN-rail-mounted direct-on-line starters to purpose-built motor control compartments in fabricated MCC enclosures. Motor control centres for HVAC plant rooms, pumping stations, process plant auxiliaries, and industrial utility systems in Saudi Arabia are typically built to IEC 61439-2 in locally fabricated forms by panel builders in Riyadh, Jeddah, Jubail, and Yanbu — and within these MCCs, the 65A contactor is one of the highest-volume components. The CD10-65/220V's TeSys D compatibility means that panel builders who have standardised on TeSys D across their MCC designs can include CD10-65 as a cost-optimised alternative in cost-sensitive project tenders without changing their standard panel drawings or procurement specifications.

The 220 VAC coil of the CD10-65/220V integrates directly with conventional relay-logic starter circuits using 220 V control voltage derived from the main 400 V supply. For large motors at 30 kW and above, DOL starting is less common than star-delta starting due to the higher starting current (typically 600–700% of rated current for DOL), and star-delta configurations using two CD10-65/220V contactors (main and star) plus one smaller delta contactor are a standard MCC compartment design in Saudi industrial projects. The availability of CD10-65/220V in pairs — or in matched sets for star-delta assemblies — from Razz Middle East's local stock simplifies procurement for panel builders constructing multiple identical MCC compartments on large project orders.

Razz Middle East supplies the CD10-65/220V with full technical support for motor starter circuit design, protection coordination with upstream MCCBs and downstream JR28 thermal overload relays, and IEC 60947-4-1 compliance documentation for project submissions. We can provide matched CDM1-100M/3300 MCCBs for upstream protection, JR28-36 thermal overload relays for the appropriate motor current range, and CD10-65/220V contactors as a complete, coordinated motor starter kit for panel builders constructing MCCs in Riyadh, Jeddah, Dammam, Jubail, and Yanbu.

Technical Specifications

Full specifications for the CD10-65/220V

Standard
IEC 60947-4-1
Poles
3
Rated Current (AC-3)
65 A
Motor Power (AC-3, 400V)
30 kW
Control Coil Voltage
220 VAC 50/60 Hz
Auxiliary Contacts
1NO + 1NC (standard)
Mounting
Screw direct mount or DIN rail adapter
Operating Temperature
-5°C to +55°C

Key Features & Benefits

  • 65A AC-3 rating at 400 V covers the 30 kW motor range that includes primary supply fans, large cooling tower fans, process pumps, and hydraulic power units — the core motor sizes in Saudi industrial and heavy commercial HVAC applications.
  • TeSys D LC1D65 compatible footprint and accessory interface enables direct substitution in existing TeSys D-based MCC compartment designs, allowing cost optimisation without redesign of type-approved panel assemblies.
  • 220 VAC control coil integrates directly into standard relay-logic DOL and star-delta starter control circuits using 220 V derived from the main 400 V supply, compatible with conventional Saudi MCC wiring practices.
  • IEC 60947-4-1 rated for 1 million AC-3 operations and suitable for star-delta starter assembly using two CD10-65/220V units (main and star contactors) plus one smaller delta contactor in standard three-contactor star-delta configurations.
  • Full accessory range including auxiliary contact blocks, surge suppressors, and mechanical interlock kits available from Razz Middle East local stock, enabling complete motor starter kit supply for MCC panel builders.

Industrial Applications in Saudi Arabia

  • Primary supply fan DOL and star-delta starters in large air handling units serving shopping centres, hospitals, universities, and government complexes across Riyadh and Jeddah, where 30 kW fan motors are standard for high-volume air handling.
  • Chiller condenser fan and cooling tower fan motor starters in district cooling plant rooms at Vision 2030 mixed-use developments and large commercial projects in Riyadh's new downtown and Jeddah's north waterfront.
  • Process pump and utility motor starters in petrochemical facility support buildings and maintenance workshops in Jubail Industrial City and Yanbu Industrial City, where IEC 60947-4-1 compliance is required for facility electrical systems.
  • Large conveyor drive and production line motor starters in manufacturing facilities across Riyadh Industrial City, Dammam Second Industrial City, and SABIC affiliate plants, using star-delta configuration for reduced-current starting.
  • Hydraulic power unit and heavy mechanical equipment motor starters in construction site temporary power systems and contractor workshop facilities on Vision 2030 mega-project sites, where robust AC-3 duty contactors withstand frequent start-stop cycling.