034855

Product image coming soon

legrand

Legrand CAB 3 Busbar Trunking System 63–250A

Model: 034855

Rated Current: 63–250 A (aluminium conductors)Conductors: 3P + N + PEEnclosure: IP55, galvanised steelSection Lengths: 0.5 m, 1 m, 2 m, 3 m
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

034855 — Legrand CAB 3 Busbar Trunking System 63–250A

The Legrand CAB 3 Busbar Trunking System is a compact, enclosed electrical power distribution system that replaces conventional cable trays and conduit in commercial buildings, industrial facilities, and data centres where frequent tap-off points are required along the length of the distribution run. The 034855 series covers the 160 A rated trunk section — one of the most popular ratings for commercial building lighting and power risers — delivering three-phase and neutral conductors enclosed in a galvanised steel housing rated IP55 for resistance to dust and water jets, suitable for both indoor distribution and outdoor or semi-outdoor routing under canopies and in plant rooms without additional weatherproofing. The system uses an aluminium conductor design for the 63 A to 250 A range, providing an optimal conductivity-to-weight ratio that reduces support structure loading compared to copper alternatives at equivalent current ratings. Pre-assembled section lengths of 0.5 m, 1 m, 2 m, and 3 m are available, with elbow, tee, and offset section variants for three-dimensional routing around structural obstructions in Saudi high-rise projects.

The defining advantage of the CAB 3 system over cable trays is the plug-in tap-off unit (TOU) that connects to any point along the busway run without interrupting power to the downstream sections — a feature that enables live tap-off additions as a building's power requirements grow, which is particularly valuable in office buildings subject to frequent tenant fit-out changes. The tap-off units for the 160 A trunk are available in configurations from 16 A to 63 A, with integral MCB, RCCB, or moulded case circuit breaker protection as required by the downstream circuit. The tap-off box is fixed to the busway housing by a quarter-turn connector that mechanically locks the electrical contacts under 17 Nm torque, preventing contact resistance from increasing under the thermal cycling loads experienced in Saudi Arabia's ambient temperature extremes. The joint between adjacent busway sections uses a bolted copper-faced pressure joint with a protection degree of IP55, maintaining the environmental rating of the complete assembly at every connection.

Saudi Arabia's construction boom — particularly the high-density commercial and residential towers in Riyadh's King Abdullah Financial District expansion, Jeddah Central's mixed-use towers, and NEOM's urban core — demands power distribution solutions that reduce floor-space consumption and adapt to changing tenant needs. Busbar trunking occupies substantially less floor-to-ceiling space than equivalent cable tray installations, and its plug-in flexibility eliminates the rewiring costs associated with tenant changes in leased commercial buildings. The CAB 3 system is favoured by SEC-registered panel builders for vertical riser distribution in multi-storey commercial and residential buildings, where its IP55 rating satisfies the electrical protection requirements at SEC inspection for plant room and riser shaft applications. Major contractor groups including Saudi Binladin Group and Al Bawani use CAB 3 as their standard busway product on commercial high-rise projects, specifying Legrand due to the local stock availability from Razz Middle East and the availability of local engineering support for riser design and coordination with structural and MEP teams.

Razz Middle East holds stock of the most common CAB 3 straight sections, elbows, and tee joints in 100 A, 160 A, and 250 A ratings, with tap-off units available from our Riyadh and Jeddah warehouses for immediate dispatch. Our team provides busbar riser design assistance including short-circuit calculation, voltage drop analysis, and support structure specification, and can prepare complete material take-off schedules for tenders. We provide IEC test certificates, installation instructions, and SEC material approval documentation with every project order.

Technical Specifications

Full specifications for the 034855

Rated Current
63–250 A (aluminium conductors)
Conductors
3P + N + PE
Enclosure
IP55, galvanised steel
Section Lengths
0.5 m, 1 m, 2 m, 3 m
Tap-Off Units
16–63 A with MCB, RCCB, or MCCB
Tap-Off Torque Lock
17 Nm quarter-turn mechanical lock
Joint Protection
IP55 bolted copper-faced pressure joint
Ambient Temperature
-25 to +40 °C
Voltage Rating
400/690 V AC
Certification
IEC 61439-6, CE, SASO

Key Features & Benefits

  • Plug-in tap-off units connect at any point along the live busway run without interrupting downstream power, enabling additional circuits to be added as a building's power requirements evolve.
  • IP55 galvanised steel enclosure resists dust and water jets, qualifying the CAB 3 for plant room, riser shaft, and semi-outdoor installations without additional weatherproofing.
  • Aluminium conductor design provides an optimal conductivity-to-weight ratio, reducing support structure loading by up to 35% compared to copper busway at equivalent current ratings.
  • Quarter-turn 17 Nm torque-lock tap-off connector maintains consistent contact resistance under thermal cycling, preventing the connection resistance increase that causes overheating on repeated high-temperature Saudi installations.
  • Pre-assembled straight, elbow, tee, and offset sections enable three-dimensional routing around structural beams and service corridors in Saudi high-rise projects without site cable fabrication.
  • IP55-rated bolted joint between sections maintains the complete assembly's environmental protection rating at every connection, satisfying SEC electrical inspection for enclosed riser shaft installations.

Industrial Applications in Saudi Arabia

  • Vertical power riser distribution in multi-storey commercial towers in Riyadh's KAFD and Jeddah Central, where busbar trunking reduces floor penetration size and adapts to changing tenant circuit demands.
  • Horizontal feeder distribution in data centre white space, where plug-in tap-offs enable live rack power additions without interrupting the data hall supply.
  • Industrial factory power distribution in MODON industrial city facilities, where the IP55 rating and plug-in tap-offs support flexible machine layout changes without rewiring the main distribution spine.
  • Shopping mall and retail centre primary distribution, where tap-off units in multiple tenant spaces provide controlled and metered power connections that can be added or removed at move-in and move-out.
  • Hospital and healthcare facility primary distribution risers, where busbar trunking's sealed IP55 housing meets infection-control requirements for clean power distribution in clinical buildings.
  • Warehouse and logistics centre power distribution, where long straight runs with frequent pick-face socket tap-offs replace hundreds of metres of heavy cable tray and conduit routing.

Industrial Supplier in Saudi Arabia

Get a Quote for the Legrand CAB 3 Busbar Trunking System 63–250A

We respond within 4 business hours. Send model 034855 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — 034855

Common questions from buyers in Saudi Arabia and the GCC