Schneider Electric Acti9 iC60H High Breaking Capacity MCB — A9F84210

schneider-electric

Schneider Electric Acti9 iC60H High Breaking Capacity MCB

Model: A9F84210

Current Range: 1–63 AVoltage: 230/400 V ACBreaking Capacity: 10 kA at 230 V / 6 kA at 400 VTrip Characteristics: B / C / D
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

A9F84210 — Schneider Electric Acti9 iC60H High Breaking Capacity MCB

The Schneider Electric Acti9 iC60H is the high breaking capacity variant of the iC60 MCB family, providing 10 kA rated breaking capacity at 230 V and 6 kA at 400 V in the same 18 mm per pole compact format as the iC60N, for applications where the available fault current on the distribution network exceeds the iC60N's 6 kA standard rating. The iC60H is required in installations close to large transformers, on low-impedance ring main supplies, and in commercial and industrial buildings where the prospective short-circuit current at the final distribution board can exceed 6 kA — conditions that apply to many of Saudi Arabia's commercial developments served by large SEC transformers and medium-voltage ring main units.

Beyond the enhanced breaking capacity, the iC60H is mechanically and dimensionally identical to the iC60N and shares the same Acti9 accessory ecosystem, enabling direct upgrade in existing panel designs without layout changes. The Visi-Trip indicator, double terminal option, and full range of trip characteristics (B, C, D) are available on iC60H as on iC60N. Selective coordination studies for commercial distribution boards in Saudi Arabia frequently specify iC60H at the final circuit level to maintain selectivity with upstream ComPacT NSX MCCBs on the sub-main circuits, as the higher breaking capacity provides better let-through energy coordination.

In Saudi Arabia, the iC60H KSA is the standard MCB specification for commercial building distribution boards in high-rise towers, shopping malls, and large institutional buildings where the proximity to large transformers or ring main supplies elevates the prospective fault current above 6 kA. The Red Sea Project's luxury resort electrical infrastructure, NEOM's smart city distribution systems, and the massive ROSHN social housing programme all include iC60H MCBs in their electrical specification packages as standard final circuit protection.

Razz Middle East maintains stock of iC60H MCBs across all current ratings (6 A to 63 A), all pole configurations, and B, C, and D trip characteristics for immediate supply to electrical contractors and panel builders throughout Saudi Arabia.

Technical Specifications

Full specifications for the A9F84210

Current Range
1–63 A
Voltage
230/400 V AC
Breaking Capacity
10 kA at 230 V / 6 kA at 400 V
Trip Characteristics
B / C / D
Poles
1P / 2P / 3P / 4P
Trip Indicator
Visi-Trip (orange)
Standard
IEC 60898-1 / IEC 60898-2
Dimension
18 mm per pole (same as iC60N)

Key Features & Benefits

  • 10 kA breaking capacity at 230 V in the standard 18 mm per pole format covers high fault current locations close to large transformers and ring main supplies without requiring larger or more expensive MCCB solutions.
  • Identical dimensions and Acti9 accessory compatibility with iC60N enables direct upgrade of existing iC60N installations to iC60H without panel layout changes, when prospective short-circuit current assessments reveal the upgrade need.
  • Better let-through energy coordination with upstream ComPacT NSX MCCBs in selective coordination studies for Saudi commercial building distribution systems, maintaining circuit selectivity at higher fault current levels.
  • Visi-Trip indicator distinguishes fault trip from manual off position in all current ratings, maintaining the diagnostic advantage of the full Acti9 range at the iC60H higher breaking capacity level.
  • Full B, C, and D trip characteristic availability matches the iC60N range, enabling identical final circuit protection specifications to be met regardless of whether iC60N or iC60H is required by the fault current level.
  • IEC 60898-1 and IEC 60898-2 dual certification covers both residential and commercial/industrial applications, satisfying Saudi Electricity Company distribution board approval requirements across all building categories.
  • Shunt trip, undervoltage release, and remote indicator accessories from the Acti9 range enable fire trip circuit isolation, emergency power-off, and remote fault signalling functions from the same iC60H MCB body.

Industrial Applications in Saudi Arabia

  • High-rise commercial tower final circuit protection in Riyadh's King Abdullah Financial District and Jeddah downtown developments, where large SEC transformers serving the towers create high prospective fault currents at distribution boards.
  • Shopping mall tenant distribution board MCBs across major Saudi mall developments in Riyadh, Jeddah, and Dammam, where low-impedance ring main supplies require 10 kA breaking capacity for SEC compliance.
  • NEOM smart city residential and commercial electrical distribution boards, where new infrastructure is designed to current IEC 60898-2 industrial standards requiring 10 kA breaking capacity throughout.
  • Red Sea Project resort hotel and villa electrical installation circuit protection, where luxury specification and proximity to dedicated MV substation transformers requires 10 kA MCBs throughout the distribution system.
  • ROSHN social housing programme electrical panel MCBs where Saudi municipality electrical inspection requires 10 kA breaking capacity in proximity to high-fault-current SEC distribution infrastructure.
  • Government ministry and institutional building electrical distribution under Ministry of Finance capital programme infrastructure, where electrical specifications require 10 kA final circuit protection throughout.
  • Healthcare facility electrical distribution in new Ministry of Health hospital projects, where iC60H's 10 kA capacity satisfies SFDA facility electrical safety standards for hospital electrical installations.

Industrial Supplier in Saudi Arabia

Get a Quote for the Schneider Electric Acti9 iC60H High Breaking Capacity MCB

We respond within 4 business hours. Send model A9F84210 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — A9F84210

Common questions from buyers in Saudi Arabia and the GCC