Schneider Electric Linergy Busbar System — LNRBS1204

schneider-electric

Schneider Electric Linergy Busbar System

Model: LNRBS1204

Conductor Sizes: 4–185 mm²Material: Pre-insulated rigid copper barConnection: Snap-fit to circuit breaker terminalsCompatibility: Acti9, ComPacT NSX, PrismaSeT chassis
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

LNRBS1204 — Schneider Electric Linergy Busbar System

The Schneider Electric Linergy BS is a pre-insulated busbar distribution system for use inside IEC 61439-compliant LV switchboards and distribution boards, designed to replace conventional copper cable distribution between the switchboard's horizontal main busbars and the individual circuit breaker terminals in multi-row panelboard and distribution board applications. The Linergy system uses rigid copper bar conductors with factory-applied insulation sleeves that snap directly onto the circuit breaker terminals and connect to the switchboard's internal distribution busbars at the other end, eliminating the need for individual conductor termination, colour-coding, and routing within the switchboard interior.

The Linergy BS is available in conductor cross-sections from 4 mm² to 185 mm², with current ratings matching the full range of Acti9 MCBs and ComPacT NSX MCCBs in the switchboard. The pre-insulated rigid bar maintains permanent contact force on the circuit breaker terminal without the risk of loose connections that can develop over time with conventional flexible cable terminations, particularly under the thermal cycling caused by load variation and Saudi Arabia's high ambient temperatures. The snap-fit connection system eliminates the need for screwdriver access behind the circuit breaker for termination, enabling circuit breaker installation and removal without disturbing adjacent conductors.

In Saudi Arabia, the Linergy BS system is used by SEC-approved LV switchboard and panel builders who assemble PrismaSeT and Okken switchboards for commercial, industrial, and infrastructure projects. The system's elimination of internal switchboard wiring labour is particularly valuable on large switchboard orders where the interior wiring of hundreds of outgoing circuits represents a significant portion of total panel build cost. Government and commercial project electrical engineers specify Linergy in switchboard design specifications to ensure consistent quality of internal distribution connections and compliance with IEC 61439-2 wiring requirements.

Razz Middle East supplies Linergy BS conductor sets for standard circuit breaker pitches and configurations to switchboard manufacturers and panel builders across Saudi Arabia.

Technical Specifications

Full specifications for the LNRBS1204

Conductor Sizes
4–185 mm²
Material
Pre-insulated rigid copper bar
Connection
Snap-fit to circuit breaker terminals
Compatibility
Acti9, ComPacT NSX, PrismaSeT chassis
Insulation
Factory-applied PVC sleeve
Temperature Rating
90°C conductor temperature
Current Ratings
Matched to MCB/MCCB ratings
Standard
IEC 61439-2 internal wiring requirement

Key Features & Benefits

  • Snap-fit connection to circuit breaker terminals eliminates screwdriver access requirements behind the breaker body, enabling circuit breaker installation and removal without disturbing adjacent conductor connections.
  • Permanent contact force from rigid bar construction prevents loose connections under thermal cycling from load variation and Saudi Arabia's high ambient temperatures, a common failure mode with conventional flexible cable terminations.
  • Factory-applied insulation eliminates field colour-coding and insulation tape application errors, ensuring consistent phasing identification and conductor insulation integrity throughout the switchboard interior.
  • Pre-cut conductor lengths for standard circuit breaker pitches eliminate field measurement and cutting, reducing switchboard interior assembly time and ensuring consistent conductor routing quality.
  • Elimination of individual cable termination for each outgoing circuit breaker reduces switchboard interior wiring labour by up to 60% on large multi-circuit panel assemblies, directly reducing switchboard build cost.
  • 90°C conductor temperature rating allows the same Linergy bar to carry the continuous current rating of the circuit breaker at Saudi Arabia's high ambient temperatures without additional current derating.
  • IEC 61439-2 internal wiring compliance documentation from Schneider Electric supports switchboard manufacturers' type-test submission packages for SEC panel approval and project technical submittals.

Industrial Applications in Saudi Arabia

  • PrismaSeT P and Okken switchboard internal distribution wiring for ARAMCO and SABIC-approved panel builder switchboard contracts, where Linergy reduces internal wiring labour cost on large multi-circuit assemblies.
  • Commercial tower distribution switchboard internal distribution by SEC-approved panel builders in Riyadh, Jeddah, and Dammam, where Linergy quality and consistency satisfies project electrical engineer inspection requirements.
  • Hospital main distribution switchboard internal distribution in Ministry of Health facility projects, where permanent contact force and insulation integrity are critical safety requirements.
  • Industrial MCC internal distribution bus connecting horizontal main busbars to outgoing circuit breaker rows in MODON industrial estate OEM manufacturing panel assemblies.
  • Government building distribution switchboard construction under Ministry of Finance capital programmes, where Linergy system compliance with IEC 61439-2 wiring requirements satisfies government procurement specification.
  • Data centre main and UPS distribution switchboard internal wiring in Saudi hyperscale facilities, where thermal cycling from dynamic IT load variation demands the Linergy's permanent contact force versus flexible cable terminations.
  • PrismaSeT G panelboard chassis internal distribution for high-density final circuit distribution boards in commercial and residential developments across Saudi Arabia.

Industrial Supplier in Saudi Arabia

Get a Quote for the Schneider Electric Linergy Busbar System

We respond within 4 business hours. Send model LNRBS1204 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — LNRBS1204

Common questions from buyers in Saudi Arabia and the GCC