Schneider PowerLogic PM1000 Basic Energy Meter — METSEPM1200

schneider-electric

Schneider PowerLogic PM1000 Basic Energy Meter

Model: METSEPM1200

Accuracy: Class 1 (IEC 62053-21)Measurements: V, I, PF, Hz, kWh, kVArhCT Input: 1 A or 5 A (selectable)Communication: RS-485 Modbus RTU
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

METSEPM1200 — Schneider PowerLogic PM1000 Basic Energy Meter

The Schneider Electric PowerLogic PM1000 series is a family of DIN-rail-mounted basic energy meters designed for sub-metering applications in commercial buildings, industrial facilities, and residential developments, providing accurate kWh consumption measurement with class 1 accuracy per IEC 62053-21 and communication via Modbus RTU for integration into building energy management systems and SCADA platforms. The PM1200 measures three-phase voltage, current, power factor, frequency, active and reactive energy — the full suite of electrical parameters needed for SEC sub-metering reporting, SGBC green building energy certification, and tenant billing in mixed-use commercial developments. Its 5 A CT input with 1 A and 5 A selectable sensitivity accommodates virtually all standard panel CT primary ratings from 50 A to 3000 A without additional instrument transformers.

The PM1000's 4-digit backlit LCD display provides direct local reading of all measured parameters without a handheld or software tool — essential for readings by facility management technicians during building rounds. The RS-485 Modbus RTU port uses standard register mapping compatible with popular SCADA platforms including Ignition, AVEVA, and Schneider's own EcoStruxure Building Operation, enabling seamless plug-and-play integration without custom driver development. Pulse output contacts enable pulse-to-kWh integration with older BMS systems and energy loggers that do not support Modbus — extending PM1000 compatibility to legacy building automation infrastructure common in Saudi Arabia's older commercial building stock.

In Saudi Arabia, the PM1000 series is the most widely installed sub-meter in commercial building metering projects, driven by SGBC mandatory sub-metering requirements for LEED and Mostadam green building certification, SEC's net-metering programme instrumentation requirements, and ARAMCO's corporate energy management programme that mandates sub-metering at all facilities above a defined energy consumption threshold. MODON industrial estate tenant utility billing systems rely on PM1000 meters to generate accurate monthly electricity bills for hundreds of tenant factories from a centralised Modbus energy management system.

Razz Middle East maintains PM1000 meters in single-phase and three-phase configurations as standard stock items, with Modbus and pulse output variants available for same-week delivery. We provide complete sub-metering system design, CT selection and sizing, Modbus addressing, and BMS integration documentation for commercial building energy management projects across Saudi Arabia.

Technical Specifications

Full specifications for the METSEPM1200

Accuracy
Class 1 (IEC 62053-21)
Measurements
V, I, PF, Hz, kWh, kVArh
CT Input
1 A or 5 A (selectable)
Communication
RS-485 Modbus RTU
Pulse Output
S0 pulse
Display
4-digit backlit LCD
Mounting
DIN rail 35 mm
Standard
IEC 62053-21, IEC 62052-11

Key Features & Benefits

  • Class 1 accuracy per IEC 62053-21 meets SGBC Mostadam sub-metering requirements and SEC net-metering programme instrumentation standards for green building energy certification.
  • Modbus RTU register map compatible with all major SCADA and BMS platforms — Ignition, AVEVA, EcoStruxure Building Operation — enables plug-and-play integration without custom driver development.
  • 1 A and 5 A CT input selectability accommodates CT primary ratings from 50 A to 3000 A without additional instrument transformers, covering all standard Saudi commercial panel current ratings.
  • S0 pulse output provides pulse-per-kWh integration with legacy BMS systems and energy loggers that pre-date Modbus communication, extending PM1000 compatibility to older Saudi building automation infrastructure.
  • 4-digit backlit LCD with direct parameter display enables local kWh reading by facility technicians during building rounds without handheld devices or software tool access.
  • DIN rail mounting with standard 35 mm rail clip installs the PM1000 in any standard distribution board or sub-panel without modification, enabling straightforward addition to existing Saudi MCB boards.
  • Low-power consumption below 2 VA from the voltage measurement circuit minimises auxiliary power draw at metering points — important when multiplying into large multi-tenant sub-metering systems.

Industrial Applications in Saudi Arabia

  • SGBC Mostadam and LEED green building certification sub-metering at commercial towers in Riyadh's King Abdullah Financial District and Jeddah's waterfront, where metered energy data feeds SGBC certification documentation.
  • MODON industrial estate tenant electricity billing at Riyadh, Jeddah, and Dammam industrial cities, where centralised Modbus PM1000 networks generate monthly tenant consumption statements.
  • Saudi Aramco facility energy management sub-metering under the corporate energy management programme, where PM1000 meters provide the consumption baseline data required for ISO 50001 certification.
  • NEOM residential community utility metering in The Line residential modules, where PM1000 meters track per-unit electricity consumption for resident billing and NEOM city-level energy accounting.
  • Commercial building tenant sub-metering in multi-tenant office towers across Riyadh, enabling landlords to bill electricity to individual tenants based on actual metered consumption rather than floor area estimation.
  • SEC net-metering programme solar PV energy export measurement at residential and commercial solar installations, where PM1000 meters satisfy SEC's bidirectional metering instrumentation requirements.
  • Hospital and healthcare facility energy monitoring under Saudi health ministry energy efficiency programmes, where PM1000 sub-meters provide department-level energy data for efficiency improvement analysis.

Industrial Supplier in Saudi Arabia

Get a Quote for the Schneider PowerLogic PM1000 Basic Energy Meter

We respond within 4 business hours. Send model METSEPM1200 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — METSEPM1200

Common questions from buyers in Saudi Arabia and the GCC