Schneider PowerLogic ION7650 Advanced Power Quality Meter — ION7650

schneider-electric

Schneider PowerLogic ION7650 Advanced Power Quality Meter

Model: ION7650

Energy Accuracy: Class 0.2S (IEC 62053-22)Power Quality: IEC 61000-4-30 Class AHarmonics: Up to 63rd orderFlicker: IEC 61000-4-15
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

ION7650 — Schneider PowerLogic ION7650 Advanced Power Quality Meter

The Schneider Electric PowerLogic ION7650 is an advanced power quality and energy management meter providing revenue-grade energy measurement (class 0.2S per IEC 62053-22), comprehensive power quality analysis including harmonics up to the 63rd order, flicker measurement per IEC 61000-4-15, and waveform capture — all in a single panel-mount instrument. The ION7650's class 0.2S energy accuracy meets the most stringent utility billing and inter-departmental cost allocation requirements, and its power quality analysis capabilities satisfy IEC 61000-4-30 Class A power quality assessment standard — the reference standard specified by ARAMCO, SABIC, and SEC for power quality audits at sensitive process plant feeders. The meter logs 200 alarm channels and 700,000 waveform samples to internal non-volatile memory, providing a continuous record of power quality events for post-event root cause analysis.

The ION7650 communicates via Ethernet (Modbus TCP, ION protocol), RS-485 (Modbus RTU, DNP3), and optional IEC 61850 MMS, enabling integration into any SCADA, energy management, or protection relay coordination system. Its ION architecture allows user-configurable calculation modules — the meter can compute custom energy parameters, KPIs, and alarm conditions without external software, embedding business logic directly in the meter hardware. The front panel display shows real-time power quality waveforms and harmonic spectrum at a glance, enabling field technicians to diagnose power quality issues without a laptop.

In Saudi Arabia, ION7650 meters are specified at 132 kV/33 kV substation secondary feeder panels, industrial plant main incomer metering for ARAMCO, SABIC, Ma'aden, and SWCC facilities, and at the point of common coupling for large renewable energy installations under REPDO's renewable energy programme. The meter's class 0.2S accuracy and IEC 61000-4-30 Class A power quality assessment make it the only meter category accepted by SEC for commercial settlement metering at industrial and large commercial customer connection points above 1 MW.

Razz Middle East supplies ION7650 meters with full CT/VT ratio programming, communication configuration, and integration testing with customer SCADA systems. Our metering engineers provide site commissioning, accuracy verification testing, and ION software configuration for complete energy management system deployments across Saudi Arabia.

Technical Specifications

Full specifications for the ION7650

Energy Accuracy
Class 0.2S (IEC 62053-22)
Power Quality
IEC 61000-4-30 Class A
Harmonics
Up to 63rd order
Flicker
IEC 61000-4-15
Waveform Capture
700,000 samples
Communication
Ethernet (Modbus TCP, ION), RS-485, IEC 61850
Alarm Channels
200
Display
Real-time waveform and harmonic spectrum

Key Features & Benefits

  • Class 0.2S energy accuracy meets SEC commercial settlement metering requirements for industrial customers above 1 MW and inter-departmental cost allocation requirements at ARAMCO and SABIC facilities.
  • IEC 61000-4-30 Class A power quality assessment standard compliance satisfies ARAMCO, SABIC, and SEC's referenced standard for power quality audits at sensitive industrial process feeder points.
  • Harmonics analysis to the 63rd order identifies high-frequency harmonic sources — variable speed drives, UPS systems, arc furnaces — that cause transformer overheating and power quality issues in industrial facilities.
  • 700,000-sample non-volatile waveform capture provides a continuous record of power quality events for post-event root cause analysis without data loss during meter power interruptions.
  • ION user-configurable calculation modules enable custom KPI computation and alarm logic programmed directly in the meter hardware, eliminating external energy management software for many monitoring applications.
  • IEC 61850 MMS option integrates ION7650 into substation protection and control architectures, enabling power quality monitoring within the same IED communication network as protection relays.
  • Real-time front panel waveform and harmonic spectrum display enables field engineers to diagnose power quality issues on-site without laptop connectivity, accelerating troubleshooting at remote Saudi industrial facilities.

Industrial Applications in Saudi Arabia

  • SEC commercial settlement metering at Saudi industrial and large commercial customer 33 kV and 132 kV connection points, where class 0.2S accuracy and Class A PQ assessment are mandatory SEC requirements.
  • ARAMCO main incomer power quality monitoring at Dhahran, Ras Tanura, and Abqaiq facilities, where ION7650 Class A assessment data satisfies ARAMCO engineering standard SAES-P-100 instrumentation requirements.
  • SABIC Jubail and Yanbu petrochemical complex power quality audit metering, where harmonic analysis identifies VFD and UPS harmonic contributions for IEEE 519 compliance assessment.
  • REPDO renewable energy plant point-of-common-coupling metering at solar and wind farm grid connection points, where ION7650 class accuracy and IEC 61850 integration satisfy SEWA grid code instrumentation requirements.
  • Ma'aden mining facility main power quality monitoring at Wa'ad Al-Shamal, where arc furnace harmonic current assessment requires 63rd-order harmonic metering to characterise the impact on the local 110 kV grid.
  • SWCC desalination plant main distribution board power quality monitoring, where the high harmonic content from large VFD drives on seawater intake pumps requires continuous IEC 61000-4-30 assessment.
  • Riyadh Metro traction power substation power quality metering, where rectifier harmonic injection into the 33 kV distribution network requires ongoing measurement for SEC power quality compliance documentation.

Industrial Supplier in Saudi Arabia

Get a Quote for the Schneider PowerLogic ION7650 Advanced Power Quality Meter

We respond within 4 business hours. Send model ION7650 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — ION7650

Common questions from buyers in Saudi Arabia and the GCC