Schneider Electric Preventa Safety Relay — XPSAF5130

schneider-electric

Schneider Electric Preventa Safety Relay

Model: XPSAF5130

Safety Functions: E-stop, safety gate, two-hand, light curtainCertification: SIL 2/3 (IEC 62061) / PLd/e (EN ISO 13849-1)Input Channels: 1 or 2 channel monitoringOutput Contacts: 2 redundant NO safety outputs
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

XPSAF5130 — Schneider Electric Preventa Safety Relay

The Schneider Electric Preventa XPSAF/XPSAV safety relay family provides certified safety input monitoring and output switching for emergency stop, safety gate, two-hand control, and light curtain safety functions in industrial machinery, covering SIL 2/3 and Performance Level d/e under IEC 62061 and EN ISO 13849-1. The XPSAF single-function safety relay monitors one or two channel safety inputs (E-stop buttons, gate switches, or safety mats) and switches two redundant output circuits with cross-monitoring, providing a self-monitoring safety loop that detects both input device failures and internal relay failures before they lead to dangerous machine operation.

The Preventa safety relay range covers the specific safety input types encountered in Saudi Arabia's industrial machinery — emergency stops (XPSAC), safety gates (XPSAV/XPSAS), two-hand controllers (XPSAT), light curtains (XPSAC), and configurable multi-function versions (XPSMC) — with clear selection guides that match the relay to the safety function type. The XPSAF and XPSAV represent the fundamental E-stop and gate monitoring variants that cover the majority of Saudi industrial machinery safety stop requirements at PLd, SIL 2. The relay's LED diagnostic display shows input channel status and fault indication, enabling rapid identification of wiring faults and input device failures without a programming tool.

In Saudi Arabia, Preventa safety relays KSA are required in any industrial machine that must comply with CE Machinery Directive safety requirements or OSHA machinery safety standards. OEM machine builders supplying to ARAMCO, SABIC, and Saudi industrial operators must demonstrate machine safety compliance to IEC 62061 or EN ISO 13849-1, with Preventa safety relays providing the certified safety function implementation. The Saudi Aramco Engineering Procedure SAEP-1031 for machinery safety requires documented safety function implementation, and Preventa relays with SIL 2 / PLd certificates satisfy this requirement with minimal engineering documentation effort.

Razz Middle East stocks Preventa XPSAF and XPSAV safety relays in the most common configurations for immediate supply to machine builders, safety system integrators, and industrial maintenance teams across Saudi Arabia.

Technical Specifications

Full specifications for the XPSAF5130

Safety Functions
E-stop, safety gate, two-hand, light curtain
Certification
SIL 2/3 (IEC 62061) / PLd/e (EN ISO 13849-1)
Input Channels
1 or 2 channel monitoring
Output Contacts
2 redundant NO safety outputs
Cross-monitoring
Internal relay and input fault detection
Diagnostics
LED input status and fault display
Supply Voltage
24 V DC / 115–230 V AC
Mounting
DIN rail

Key Features & Benefits

  • TÜV-certified SIL 2 / PLd safety category satisfies CE Machinery Directive and ARAMCO SAEP-1031 machinery safety documentation requirements with minimal engineering effort and maximum audit acceptance.
  • Two-channel input monitoring with cross-checking detects simultaneous failure of both input channels, a fault mode that single-channel relays cannot detect and that can lead to undetected loss of safety function.
  • Redundant output contacts provide two independent circuits that must both open to create the safety stop condition, preventing dangerous single-contact failure modes from maintaining machine power during an emergency stop.
  • LED diagnostic display shows input A, input B, output, and fault status without a configuration tool, enabling maintenance technicians to rapidly diagnose wiring faults and input device failures on the production floor.
  • Function-specific variants for E-stop (XPSAF), gate (XPSAV), two-hand (XPSAT), and light curtain (XPSAC) applications provide clear, application-matched safety relay selection that simplifies CE documentation and machinery risk assessment.
  • 24 V DC supply option suits 24 V control circuit panels common in modern Saudi industrial machinery, while 115/230 V AC option serves older installations and building services applications without a 24 V power supply.
  • Compact DIN rail mounting with standard 22.5 mm width allows multiple safety relays for different machine guarding zones to be installed in the same panel section without excessive space consumption.

Industrial Applications in Saudi Arabia

  • Emergency stop circuit monitoring on OEM machinery supplied to ARAMCO and SABIC facilities, where XPSAF SIL 2 certification satisfies ARAMCO SAEP-1031 documented safety function implementation requirements.
  • Safety gate monitoring on robot cell perimeter guarding at NEOM advanced manufacturing facilities, where PLd certification and two-channel monitoring satisfy EN ISO 13849-1 risk assessment requirements.
  • Light curtain safety input monitoring on press and stamping machines at Saudi metal fabrication facilities in MODON industrial zones, where Preventa XPSAC interfaces the light curtain output to the machine safety circuit.
  • Two-hand control safety relay for press and metal forming machine operator protection at Saudi industrial machinery installations, where XPSAT ensures simultaneous two-hand engagement before the press cycle initiates.
  • Conveyor system emergency stop relay networks at Saudi food processing and packaging facilities in MODON zones, where XPSAF monitors E-stop buttons across long conveyor runs with diagnostic display for rapid fault finding.
  • Machinery safety gate monitoring at cement and mineral processing plant guarded areas in Saudi Arabia, where Preventa relays satisfy ARAMCO and international contractor machinery safety compliance requirements.
  • Electrical panel door guard monitoring at high-voltage electrical test equipment rooms in Saudi utilities and industrial laboratories, where XPSAV gate relay prevents panel energisation while access doors are open.

Industrial Supplier in Saudi Arabia

Get a Quote for the Schneider Electric Preventa Safety Relay

We respond within 4 business hours. Send model XPSAF5130 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — XPSAF5130

Common questions from buyers in Saudi Arabia and the GCC