Socomec ATyS 6D 160A 4-Pole Automatic Transfer Switch

Model: 3120 6400

Rated Current: 160ANumber of Poles: 4-pole (including switched neutral)Standard: IEC 60947-6-1 / NFPA 110 Level 1 compatibleSupply Voltage: 380/400 V AC 3-phase
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

3120 6400 — Socomec ATyS 6D 160A 4-Pole Automatic Transfer Switch

The Socomec ATyS 6D 160A 4-Pole Automatic Transfer Switch (model 3120 6400) is an IEC 60947-6-1 compliant automatic transfer switch engineered for medium-duty commercial and industrial applications requiring reliable grid-to-generator changeover at 160A continuous rating. The ATyS 6D 160A occupies a critical niche in the Saudi Arabian market: it bridges the gap between small residential-scale ATS units and full motor-operated MV switchgear, making it the standard selection for retail mall sub-boards, hotel floor distribution boards, hospital wing feeders, and industrial plant room distribution panels where loads run from 50 kW to approximately 80 kW. Its 4-pole architecture satisfies SEC and ARAMCO engineering standards for installations requiring full neutral switching, and the unit is pre-approved under several ARAMCO and Ministry of Health engineering specification packages.

The 3120 6400 incorporates Socomec's advanced source quality monitoring engine, which evaluates SEC grid supply and generator output across multiple parameters simultaneously: phase-to-neutral and phase-to-phase voltage for all three phases, supply frequency (with adjustable deviation windows around 50 Hz), phase sequence, and phase loss detection. This multi-parameter monitoring prevents premature transfer to a generator with a faulty AVR, or retransfer to a grid supply that is still in a brownout condition — both failure modes that cause expensive load equipment damage in facilities where power quality events are common, such as industrial zones in Jubail and Dammam or areas served by overhead distribution networks in rural Saudi regions.

In the Saudi market, ATyS 6D 160A units are a standard product in hospital backup systems at King Fahad Medical City, Saudi German Hospital networks, and Ministry of Health district hospitals across the Kingdom. The unit's compliance with NFPA 110 Level 1 transfer switch requirements — in addition to IEC standards — makes it acceptable to hospital engineers who reference both international codes, a common situation in Saudi Arabia's mixed-standards environment. For NEOM project MEP contractors, the ATyS 6D series provides the documented SEC-compatible transfer switch specification required in Smart City building codes.

Razz Middle East maintains stock of common ATyS 6D ratings including the 160A model and can deliver to any location in Saudi Arabia within standard lead times. Our applications team provides generator compatibility checks, panel layout design, and commissioning support as part of the standard supply package for qualified contractors and end users across Riyadh, Jeddah, Dammam, Khobar, Jubail, and Yanbu.

Technical Specifications

Full specifications for the 3120 6400

Rated Current
160A
Number of Poles
4-pole (including switched neutral)
Standard
IEC 60947-6-1 / NFPA 110 Level 1 compatible
Supply Voltage
380/400 V AC 3-phase
Monitoring
Voltage, frequency, phase sequence, phase loss
Transfer Time
Approx. 60 ms (open transition)
Operating Temperature
-25 to +55°C
Degree of Protection
IP20 (panel mount)

Key Features & Benefits

  • 160A continuous rating suits medium commercial distribution boards and hospital wing feeders, bridging the range between small residential ATS units and large motor-operated switchgear.
  • Multi-parameter source quality monitoring evaluates phase voltage, frequency deviation, phase sequence, and phase loss on both sources simultaneously to prevent transfer to a degraded incoming supply.
  • Dual standard compliance with IEC 60947-6-1 and NFPA 110 Level 1 transfer switch requirements satisfies both European and North American code references used in Saudi Arabia's mixed-standards project environment.
  • User-adjustable voltage thresholds (typically ±10–15% of nominal) and frequency windows (±1–3 Hz) allow fine-tuning for generator AVR characteristics and local grid stability conditions.
  • Compact molded case with front-accessible control wiring terminals accelerates panel assembly and reduces commissioning time compared to modular relay-based ATS solutions.
  • Integrated event log with time-stamped transfer records supports preventive maintenance scheduling and incident reporting for facilities under ISO 50001 or ARAMCO asset management programmes.

Industrial Applications in Saudi Arabia

  • Backup power transfer switching for hospital wing distribution boards at King Fahad Medical City, Saudi German Hospital facilities, and Ministry of Health district hospitals where NFPA 110 and SEC compliance is mandatory.
  • Generator/grid changeover for hotel floor distribution panels in Vision 2030 hospitality projects including Red Sea Project resorts and NEOM Welcome Village facilities.
  • Medium commercial building sub-distribution board backup supply in retail mall tenancy panels across Riyadh, Jeddah, and Dammam, where the 160A rating covers typical 3-phase shop unit loads.
  • Industrial plant room distribution panel backup changeover at SABIC and ARAMCO support facilities, where the 4-pole specification meets corporate engineering standards for neutral switching.
  • Telecommunications central office backup changeover for STC and Mobily exchange buildings, where multi-parameter monitoring prevents retransfer to a still-degraded grid supply after a power disturbance.