eaton
Eaton IQ 260 Power Quality Meter
Model: IQ260
4-hour response · Pricing in SAR · Delivery across all KSA regions
IQ260 — Eaton IQ 260 Power Quality Meter
The Eaton IQ 260 Power Quality Meter is an advanced multifunction power quality analyser and energy meter that extends beyond basic energy measurement to provide harmonic analysis, waveform capture, sag and swell detection, and TCP/IP Ethernet communication — making it the instrument of choice for facilities engineers in Saudi Arabia who need to diagnose power quality problems as well as measure energy consumption. The IQ260 measures voltage and current harmonics up to the 63rd order with THD calculations, captures triggered waveform events to internal memory for post-event analysis, and records minimum-maximum-average trends for all parameters at configurable intervals. Its native TCP/IP Modbus interface connects directly to plant SCADA systems, energy management software, and building management systems over standard Ethernet infrastructure without serial RS-485 wiring.
The IQ 260's power quality analysis capability is particularly valuable in Saudi Arabia's industrial sector, where the proliferation of large variable frequency drives, UPS systems, and arc furnaces in steel mills generates substantial voltage harmonic distortion that can exceed IEEE 519-2022 and Saudi SEC technical specifications for grid connection. The meter's 63rd harmonic analysis identifies the dominant harmonic orders and their magnitudes, enabling engineers to specify correctly sized harmonic filters and passive reactors without expensive third-party power quality surveys. The waveform capture function records pre- and post-event voltage and current waveforms at up to 512 samples per cycle, preserving the signature of momentary events such as transformer inrush, motor starting, and capacitor switching transients.
Across the Kingdom, the IQ 260 is deployed in Saudi Aramco GOSPs and gas processing facilities for IEEE 519 compliance monitoring at the grid interface, in SWCC and MARAFIQ desalination plants for large drive system harmonic assessment, and in Ministry of Health hospital electrical infrastructure projects where uninterruptible power and stable power quality are life-safety requirements. NEOM's smart-grid infrastructure programme specifies power quality meters at every primary distribution point to provide the real-time grid health data needed for intelligent demand management and storage dispatch decisions.
Razz Middle East supplies the IQ 260 with full TCP/IP configuration, register mapping to customer SCADA or BMS platforms, and on-site commissioning across Saudi Arabia. We provide application engineering support for harmonic compliance studies and IEEE 519 reporting. Local stock in Riyadh and Dammam with 4-hour RFQ response and SAR pricing.
Technical Specifications
Full specifications for the IQ260
- Harmonic Analysis
- Up to 63rd order, THD
- Waveform Capture
- Up to 512 samples/cycle, triggered
- Communication
- TCP/IP Modbus (Ethernet) + RS-485
- Parameter Recording
- Min/Max/Avg trends, configurable intervals
- Sag/Swell Detection
- Per IEC 61000-4-11
- Panel Cutout
- 96×96 mm
- Display
- Graphical LCD
- Aux Supply
- 85–265 V AC/DC
Key Features & Benefits
- 63rd harmonic order voltage and current analysis with THD calculations enables IEEE 519-2022 compliance assessment and precise harmonic filter specification without third-party power quality surveys.
- Triggered waveform capture at up to 512 samples per cycle records pre- and post-event voltage and current signatures for post-event analysis of transformer inrush, motor starts, and transients.
- Native TCP/IP Modbus Ethernet communication connects directly to SCADA, BMS, and energy management systems over standard plant LAN infrastructure without RS-485 serial converters.
- Configurable min/max/average trend recording for all parameters at selectable intervals builds historical power quality and energy performance datasets for long-term analysis.
- Sag and swell detection per IEC 61000-4-11 automatically logs power quality events with timestamps, enabling facilities teams to correlate events with process disturbances or equipment failures.
- 96×96 mm panel format maintains compatibility with standard switchgear panel cutouts while delivering power quality analyser functionality previously requiring standalone instrument cases.
Industrial Applications in Saudi Arabia
- Saudi Aramco GOSP and gas processing facility IEEE 519-2022 compliance monitoring at the utility grid interface point, providing harmonic distortion data for SEC technical specification compliance.
- SWCC and MARAFIQ desalination plant large VFD harmonic assessment, where 63rd-order analysis identifies dominant harmonic orders for passive filter specification.
- Ministry of Health hospital electrical infrastructure power quality monitoring, where stable voltage is a life-safety requirement for surgical and ICU equipment performance.
- NEOM smart-grid primary distribution points where real-time power quality data feeds intelligent demand management and battery storage dispatch algorithms.
- Steel and aluminium smelter facilities monitoring arc furnace flicker and harmonic injection for Saudi SEC connection compliance assessments.
- Data centre UPS system input power quality analysis to verify generator and utility supply meets IEC 62040-3 VFI input requirement specifications.
Industrial Supplier in Saudi Arabia
Get a Quote for the Eaton IQ 260 Power Quality Meter
We respond within 4 business hours. Send model IQ260 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.
Frequently Asked Questions — IQ260