
eaton
Eaton NZM1 Power Circuit Breaker
Model: N1-63
4-hour response · Pricing in SAR · Delivery across all KSA regions
N1-63 — Eaton NZM1 Power Circuit Breaker
The Eaton NZM1 Power Circuit Breaker is a compact moulded-case circuit breaker covering the 63 A to 160 A current rating range, designed for motor branch circuit protection, feeder protection, and power distribution switching in industrial and commercial electrical systems. The NZM1 family encompasses three breaking capacity variants — N (Normal, 36 kA at 415 V), H (High, 50 kA), and L (Extra-high, 85 kA) — allowing the engineer to precisely match the device's short-circuit breaking capacity to the calculated fault level at the installation point without over-specifying and incurring unnecessary cost. All variants use the same physical frame and DIN mounting dimensions, simplifying panel layout planning and enabling upgrade from N to H or L type in the field by device replacement without panel modification. The fixed and adjustable thermal-magnetic trip units available for the NZM1 cover both the fixed-setting motor protection variant and the adjustable overload-band version for feeder and generator protection applications.
The NZM1's thermomagnetic trip unit provides two independent protection functions: a thermal bimetallic element for time-delayed overload protection calibrated to IEC trip classes, and a magnetic instantaneous trip element for short-circuit interruption. The instantaneous trip threshold is factory set at approximately 12× the rated current for motor-circuit variants, coordinating with DOL motor starting currents to avoid nuisance tripping during acceleration while still providing rapid fault clearance for short-circuit conditions. The adjustable NZM1 variant allows the thermal overload pickup to be adjusted between 63 and 160 A across the device's full frame rating, making it suitable for feeder circuits supplying variable load groups without requiring a different device for each cable size. The rotary operating handle includes provisions for padlock lockout (3 padlocks simultaneously), enabling LOTO compliance per IEC 60204-1 and Saudi Aramco's electrical safety management system.
In Saudi Arabia, the NZM1 is a fundamental building block of industrial and commercial LV power distribution, used extensively in SEC-metered main switchboards, generator output circuit breakers, industrial MCC incomer feeders, and MVAC panel feeders serving large HVAC and process equipment loads. Saudi Aramco SAES-P-100 series specifications reference the NZM1 for motor branch circuit protection applications where the PKZM motor protective circuit breaker is too small. NEOM and KAPSARC infrastructure panels, Red Sea Project accommodation village main distribution boards, and SDAIA cloud city data centre LV distribution use the NZM1 for 63–160 A feeder protection. Commercial panel builders in Riyadh, Jeddah, and Dammam specify the NZM1 for retailtenant distribution boards, hotel floor distribution panels, and hospital zone distribution boards where 36–85 kA fault current immunity is required by SASO and NEC-based local electrical codes.
Razz Middle East stocks the NZM1 family across the full 63–160 A current range and all three breaking capacity variants (N, H, L) in both fixed and adjustable thermal-magnetic trip configurations. We provide device selection support based on calculated fault levels, load flow analysis, and selectivity requirements, issuing coordination study summaries suitable for project submission to Saudi Aramco, SABIC, and SEC. Our Riyadh and Dammam warehouses carry sufficient stock to fulfil same-week delivery for typical project quantities, with urgent maintenance supply available same-day for Riyadh, Al Khobar, and Jubail locations.
Technical Specifications
Full specifications for the N1-63
- Current Range
- 63–160 A
- Breaking Capacity (N/H/L)
- 36 / 50 / 85 kA at 415 V
- Trip Unit
- Thermomagnetic (fixed or adjustable)
- Instantaneous Trip
- ~12× In (motor variant)
- Mounting
- DIN rail or panel mounting
- LOTO
- 3-padlock provision
- Standard
- IEC 60947-2
- Ambient Temperature
- Up to +50°C
Key Features & Benefits
- Three breaking capacity variants (N/H/L: 36/50/85 kA) in identical frame dimensions allow fault-level-matched specification without panel redesign, covering the full range of Saudi industrial distribution fault levels.
- Thermomagnetic trip unit with ~12× In instantaneous threshold for motor variants coordinates with DOL starting currents, preventing nuisance trips while ensuring rapid fault clearance.
- Adjustable thermal overload pickup across full 63–160 A frame range accommodates variable feeder load groups without requiring device replacement when load compositions change.
- Three-padlock LOTO provision on the rotary handle enables simultaneous multi-trade isolation per IEC 60204-1 and Saudi Aramco GI-2.100 procedures.
- Same DIN mounting footprint across all three breaking capacity variants allows N-to-H or H-to-L upgrade in the field without panel modification when fault levels are revised during engineering.
- Compatible with Eaton's full range of NZM1 accessories including auxiliary contacts, shunt trip coils, undervoltage releases, and rotary handle extensions for remote switching.
Industrial Applications in Saudi Arabia
- Motor branch circuit protection in industrial MCC incomers and feeder panels at Saudi Aramco GOSP, refinery, and terminal facilities across the Eastern Province.
- Generator output circuit breakers at emergency power systems in hospitals, data centres, and critical facilities requiring 50–85 kA breaking capacity.
- NEOM and KAPSARC infrastructure LV distribution panel feeders, where standardisation on the NZM1 family simplifies spares management across multiple project sites.
- SEC main metering switchboard feeder protection for commercial and industrial customers across Riyadh, Jeddah, and Dammam distribution networks.
- Retail tenant distribution board incomer breakers in shopping malls and airport terminals, where adjustable thermal overload accommodates seasonal load variations.
- Hospital zone and floor distribution board incomer breakers, where high breaking capacity and LOTO capability are required by CBAHI and MOH healthcare facility electrical standards.
Industrial Supplier in Saudi Arabia
Get a Quote for the Eaton NZM1 Power Circuit Breaker
We respond within 4 business hours. Send model N1-63 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.
Frequently Asked Questions — N1-63
Common questions from buyers in Saudi Arabia and the GCC