Eaton xPole PL7 Miniature Circuit Breaker — PL7-C16/1

eaton

Eaton xPole PL7 Miniature Circuit Breaker

Model: PL7-C16/1

Current Range: 1–63 ACharacteristics: B / C / DBreaking Capacity: 10 kA at 230/400 V ACStandard: IEC 60947-2
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

PL7-C16/1 — Eaton xPole PL7 Miniature Circuit Breaker

The Eaton xPole PL7 Miniature Circuit Breaker is the high-breaking-capacity variant of Eaton's xPole MCB family, delivering a 10 kA breaking capacity at 230/400 V AC in the same DIN 17.5 mm per pole footprint as the standard PL6, making it directly interchangeable in the same distribution board without panel modification. The PL7 is engineered for applications where the prospective short-circuit current at the MCB installation point exceeds the 6 kA limit of standard IEC 60898-1 MCBs — typically in distribution boards positioned close to large distribution transformers (1000 kVA and above) or on high-capacity urban distribution networks where SEC's distribution transformer density creates elevated fault levels at service-entrance panels. IEC 60947-2 classification (rather than the domestic IEC 60898-1 of the PL6) gives the PL7 additional capabilities including higher rated currents and an extended operational performance class, making it suitable for both final circuit and sub-distribution applications in commercial and light industrial buildings.

The PL7's arc extinguishing system is enhanced relative to the PL6 to handle the additional arc energy released during fault current interruption at the higher 10 kA prospective fault current levels. The arc splitter stack in the PL7 is deeper and uses additional splitter plates, increasing the number of arc segments and thus the arc voltage required to sustain the arc against the supply EMF — causing rapid arc extinction within the first half-cycle of fault current. This fast arc extinction limits the let-through energy (I²t) to values that protect downstream wiring insulation and upstream contacts from fault-current thermal damage, even when the fault occurs at maximum peak current. In the C characteristic, the PL7's instantaneous magnetic trip threshold of 5–10× rated current is identical to the PL6, maintaining full backward compatibility with existing circuit designs when upgrading from PL6 to PL7 for increased breaking capacity without reissuing protection coordination studies.

Saudi Arabia's urban distribution networks — particularly in central Riyadh, Jeddah, and Dammam commercial districts — exhibit progressively higher fault levels as SEC invests in network reinforcement and higher-capacity distribution transformers to serve the Kingdom's growing electricity demand driven by Vision 2030 economic expansion. This network strengthening is driving specification of 10 kA MCBs even in commercial building distribution boards where 6 kA was previously sufficient, as the higher fault levels make under-specified MCBs a potential explosion hazard. Saudi Aramco's SAES-P-104 standard references 10 kA as the minimum breaking capacity for final circuit MCBs installed in industrial facility distribution boards, making the PL7 the standard MCB specification for Aramco EPC projects. NEOM's power distribution design specifications and KAPSARC's facility electrical standards also specify 10 kA MCBs throughout their distribution hierarchy.

Razz Middle East carries the complete xPole PL7 range covering all standard current ratings from 1 A to 63 A, tripping characteristics B, C, and D, and pole counts 1P, 2P, 3P, and 4P. We supply the PL7 alongside the PL6 in project BOMs where the engineer has specified 10 kA breaking capacity at specific circuit locations, providing a single-source supply of the complete Eaton xPole MCB range. Our technical team assists in identifying which circuits in a distribution board require PL7 versus PL6 based on calculated prospective fault currents, reducing unnecessary cost uplift from blanket 10 kA specification while maintaining code compliance at all circuits.

Technical Specifications

Full specifications for the PL7-C16/1

Current Range
1–63 A
Characteristics
B / C / D
Breaking Capacity
10 kA at 230/400 V AC
Standard
IEC 60947-2
Poles
1P / 2P / 3P / 4P
DIN Width
17.5 mm per pole
Instantaneous Trip (C curve)
5–10× In
Ambient Temperature
-25°C to +50°C

Key Features & Benefits

  • 10 kA breaking capacity at 400 V AC meets Saudi Aramco SAES-P-104 and NEOM distribution specification requirements for final circuit MCBs in industrial and infrastructure distribution boards.
  • Same DIN 17.5 mm per pole footprint as PL6 allows direct drop-in upgrade from 6 kA to 10 kA breaking capacity without distribution board modification or incomer resizing.
  • Enhanced arc splitter stack with additional splitting plates achieves rapid arc extinction within the first fault current half-cycle, limiting I²t let-through energy to protect wiring insulation at 10 kA fault levels.
  • IEC 60947-2 industrial classification (vs. IEC 60898-1 for PL6) enables use in both final circuit and sub-distribution applications requiring the higher operational class.
  • Identical instantaneous trip thresholds to the PL6 in corresponding characteristics (B/C/D) maintains full coordination study compatibility when upgrading from PL6 to PL7.
  • Covers Riyadh, Jeddah, and Dammam central commercial district distribution boards where SEC network reinforcement has elevated prospective fault levels beyond 6 kA at service-entrance panels.

Industrial Applications in Saudi Arabia

  • Final circuit MCBs in Saudi Aramco industrial facility distribution boards per SAES-P-104, which mandates 10 kA breaking capacity for all MCBs in industrial distribution systems.
  • Commercial building service-entrance distribution boards in central Riyadh, Jeddah, and Dammam where SEC network fault levels exceed 6 kA at the service entrance.
  • NEOM and KAPSARC distribution boards throughout the electrical hierarchy, per project specifications mandating 10 kA MCBs for all final circuit protection.
  • Hospital and critical facility distribution boards where IEC 60947-2 classification provides additional performance confidence over domestic-grade IEC 60898-1 MCBs.
  • Upgrade replacement for installed PL6 MCBs in existing distribution boards at facilities where network fault level increases following SEC transformer upgrades.
  • High-rise residential and commercial tower distribution boards near city centre primary substations in Riyadh and Jeddah, where building proximity to grid infrastructure elevates fault levels.

Industrial Supplier in Saudi Arabia

Get a Quote for the Eaton xPole PL7 Miniature Circuit Breaker

We respond within 4 business hours. Send model PL7-C16/1 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — PL7-C16/1

Common questions from buyers in Saudi Arabia and the GCC