PXF-40/2/003/A — Eaton xPole PXF Residual Current Circuit Breaker
The Eaton xPole PXF Residual Current Circuit Breaker (RCCB) is a dedicated earth leakage protection device covering the 25 A to 100 A current range with residual current sensitivity settings of 30 mA, 100 mA, and 300 mA, available in Type AC (AC sinusoidal fault currents) and Type A (AC sinusoidal and pulsating DC fault currents) variants to IEC 61008-1 and EN 61008-1 standards. The PXF provides pure residual current protection without overcurrent protection, and is designed to be used in combination with upstream MCBs (PL6 or PL7) or circuit breakers (NZM1) to create a complete earth fault and overcurrent protection scheme at the circuit level. The Type A variant addresses the increasingly important requirement to detect pulsating DC fault currents generated by variable frequency drives (VFDs), electronic lamp ballasts, computer power supplies, and other switched-mode power electronic loads that are proliferating across Saudi Arabia's commercial buildings, data centres, and industrial facilities as part of energy efficiency and digitalisation programmes.
The PXF's electromechanical sensing circuit measures the vector sum of currents in all poles simultaneously using a toroidal sensing transformer, tripping the contact mechanism when the vector sum — which is zero for a perfectly balanced system — exceeds the sensitivity threshold due to an earth leakage path from any live conductor. The tripping time at 1× sensitivity threshold is less than 300 ms (meeting IEC requirements for 30 mA devices to prevent ventricular fibrillation), while at 5× threshold or above, the PXF trips in under 40 ms, providing fast fault energy limitation. A test pushbutton simulates the leakage condition through an internal test resistor, verifying the correct operation of the sensing circuit and mechanical trip mechanism in situ without simulating an actual earth fault — an important monthly maintenance procedure required by Saudi Electricity Authority electrical safety regulations and IEC 60364-6 initial verification requirements.
In Saudi Arabia, RCCB devices are mandatory for specific circuit types under SASO 2845 (the Saudi equivalent of BS 7671) including bathroom and kitchen circuits in residential and hotel applications, outdoor socket-outlet circuits, pool and fountain circuits, and circuits supplying temporary construction site power. The 30 mA sensitivity of the PXF-40/2/003/A model is the standard people-protection threshold specified for these applications, while 100 mA and 300 mA models are used for fire protection (detecting high-impedance earth faults that can cause smouldering fires) and equipment protection (preventing large earth fault currents from damaging sensitive equipment). Saudi Aramco's SAES-P-102 specifies RCCB protection for certain residential compound and office building circuits, and SEC's connection regulations require RCCB protection on socket outlet circuits for all new building connections across the Kingdom. The Type A variant is increasingly specified for circuits supplying VFD motor drives, computer rooms, and BMS control panels.
Razz Middle East stocks the PXF RCCB in 25 A, 40 A, 63 A, and 100 A ratings, in 2-pole and 4-pole configurations, across 30 mA, 100 mA, and 300 mA sensitivity settings, in both Type AC and Type A variants. We assist panel builders in selecting the correct PXF variant for each application, including SASO 2845 compliance checking and coordination verification with upstream MCBs. Our stock depth allows full project BOM fulfilment for residential and commercial projects, with same-week delivery across Saudi Arabia from our Riyadh warehouse.
Technical Specifications
Full specifications for the PXF-40/2/003/A
- Current Range
- 25–100 A
- Residual Current Sensitivity
- 30 / 100 / 300 mA
- Types
- AC (sinusoidal) and A (sinusoidal + pulsating DC)
- Standard
- IEC 61008-1, EN 61008-1
- Poles
- 2P / 4P
- Trip Time at 1× Sensitivity
- <300 ms
- Trip Time at 5× Sensitivity
- <40 ms
- Test Function
- Built-in pushbutton
Key Features & Benefits
- Type A variant detects both AC sinusoidal and pulsating DC residual currents from VFDs, switched-mode power supplies, and electronic ballasts — essential for modern commercial and industrial circuits in Saudi Arabia.
- 30 mA people-protection sensitivity meets IEC 60364-4-41 and SASO 2845 requirements for bathroom, kitchen, outdoor socket, and pool circuits mandated for all new building connections in the Kingdom.
- Toroidal sensing transformer measures all-phase current vector sum with high sensitivity and immunity to transient overcurrents, preventing false tripping from motor starting, transformer inrush, and lightning-induced surges.
- Built-in test pushbutton enables monthly verification of sensing circuit and mechanical trip function in situ, meeting Saudi Electricity Authority electrical safety inspection and IEC 60364-6 requirements.
- Available in 2-pole and 4-pole variants covering single-phase 230 V and three-phase 400 V circuits, accommodating the full range of protected circuit types in residential and commercial distribution boards.
- Snap-on DIN mounting with same xPole width profile as PL6/PL7 MCBs allows compact split-load board designs with MCB and RCCB in a coordinated single-enclosure distribution board.
Industrial Applications in Saudi Arabia
- Bathroom, kitchen, and outdoor socket-outlet earth leakage protection in SASO 2845 compliant residential and hotel distribution boards across Saudi Arabia.
- Saudi Aramco residential compound circuit protection per SAES-P-102 for bathroom and outdoor circuits in villa and apartment distribution boards at Dhahran, Ras Tanura, and Abqaiq.
- Pool, fountain, and water feature circuit earth leakage protection at NEOM Sindalah, Red Sea Project resorts, and Diriyah Gate entertainment venues.
- VFD motor circuit Type A RCCB protection in commercial HVAC and industrial motor panels where pulsating DC fault currents from variable speed drives require Type A detection capability.
- Construction site temporary power panel RCCB protection per Saudi Labour Ministry construction safety regulations, protecting workers from electric shock at 30 mA sensitivity.
- Computer room and BMS control panel earth leakage fire protection at 100–300 mA sensitivity, detecting high-impedance smouldering earth faults before they escalate to fire events.