Model: ADN916D
4-hour response · Pricing in SAR · Delivery across all KSA regions
ADN916D — Hager Volta RCBO 1P+N 16A 30mA
The Hager Volta ADN916D is a 1P+N Residual Current Circuit Breaker with Overcurrent protection (RCBO) rated 16 amperes with 30 mA residual current sensitivity in Type A classification. This device combines the functions of a standard MCB and a residual current device (RCD) in a single 2-module DIN rail unit, providing simultaneous protection against both overcurrent/short-circuit faults and earth leakage that can cause electrocution or fire. The 30 mA sensitivity is the internationally recognised threshold for personal protection against lethal electric shock, and the Type A classification ensures the device responds correctly to both sinusoidal and pulsating DC residual currents — covering the full range of fault types generated by modern electronic loads including variable-speed drives, LED drivers, and switched-mode power supplies.
In Saudi Arabia, the use of RCDs and RCBOs in residential and hotel electrical installations has increased significantly since the Saudi Building Code began incorporating IEC 60364 requirements for additional protection in wet areas, outdoor circuits, and socket outlets intended for general use. The Hager Volta ADN916D's SASO certification and compliance with IEC 61009-1 make it acceptable to Saudi Electricity Company inspectors and municipality electrical inspection teams without the need for additional waivers or equivalence documentation. This compliance simplicity accelerates project handover — a significant operational benefit in fast-moving hospitality developments in Mecca and Medina, where electrical final inspections must be completed under strict opening-date pressure.
The ADN916D's compact 2-module footprint (36 mm) is a critical advantage over the traditional approach of installing a separate MCB and RCD, which typically occupies 3 to 4 modules and requires additional busbar connections. In hotel guest room distribution boards, where a 12-way enclosure may need to accommodate circuits for air conditioning, lighting, bathroom, and general sockets, every saved module translates directly into a smaller, lighter, and less expensive panel enclosure. This space efficiency makes the ADN916D the preferred choice for interior design-driven projects across NEOM's luxury hospitality portfolio, Red Sea Project eco-resorts, and Diriyah Gate's boutique hotel developments.
Razz Middle East supplies the full Hager Volta RCBO range — ADN9 series across 6A, 10A, 16A, 20A, 25A, and 32A at both 10 mA and 30 mA sensitivities — from local Saudi inventory. We provide full IEC 61009-1 test certificates, SASO approval documentation, and technical data sheets in Arabic and English to support submittals to main contractors, consultants, and the Saudi Electricity Company. Our application engineering team can assist with RCD selectivity coordination between upstream and downstream devices to comply with IEC 60364-5-53 requirements.
Technical Specifications
Full specifications for the ADN916D
- Rated Current
- 16 A
- Number of Poles
- 1P+N
- Residual Current Sensitivity
- 30 mA
- RCD Type
- Type A
- Breaking Capacity
- 6 kA
- Voltage Rating
- 230 V AC
- Standard
- IEC 61009-1 / SASO
- Width
- 36 mm (2 modules)
Key Features & Benefits
- Combined RCBO function integrates MCB overcurrent protection and 30 mA RCD earth-leakage protection in a single 2-module device, saving panel space and eliminating the additional wiring required for separate MCB and RCD combinations.
- Type A residual current classification responds to both sinusoidal AC and pulsating DC earth fault currents, covering the fault current waveforms generated by LED lighting drivers, SMPS chargers, and variable-frequency motor drives.
- 30 mA sensitivity is the IEC and WHO-recognised threshold for personal protection against lethal electric shock, mandatory under IEC 60364-4-41 for socket outlet circuits and bathroom circuits in residential and hospitality buildings.
- SASO certified to IEC 61009-1, ensuring acceptance by Saudi Electricity Company inspectors and municipality electrical inspection teams without additional equivalence documentation or waivers.
- Compact 2-module DIN rail footprint (36 mm) versus 3–4 modules for equivalent separate MCB + RCD, maximising circuit density in space-constrained hotel guest room and apartment distribution boards.
- Independent overcurrent and earth-leakage trip indicators allow maintenance technicians to diagnose whether a trip was caused by overload, short circuit, or earth leakage — reducing diagnostic time in 24/7 hospitality operations.
Industrial Applications in Saudi Arabia
- Bathroom and wet area socket outlet circuits in hotel guest rooms across Mecca, Medina, and Jeddah, where IEC 60364-7-701 requires 30 mA RCD protection within 3 metres of any bath or shower zone.
- General-purpose socket outlet circuits in NEOM luxury residential and hotel precincts, where the project specification requires RCD protection on all final circuits in compliance with IEC 60364-4-41 additional protection requirements.
- Kitchen appliance circuits in Red Sea Project eco-resort villas and bungalows, where compact panel sizes mandate combined RCBO devices rather than separate MCB and RCD assemblies.
- Outdoor and garden lighting circuits in ARAMCO residential compounds and Royal Commission for Yanbu housing developments, where earth fault protection is required on all circuits with cables buried or exposed to moisture.
- Healthcare and elderly care facility socket circuits in Vision 2030 social infrastructure projects in Riyadh and other major cities, where patient safety regulations mandate 30 mA earth fault protection on all accessible outlets.