LS AHF Active Harmonic Filter — LSAHF-100A

ls-electric

LS AHF Active Harmonic Filter

Model: LSAHF-100A

Compensation Current: 30–200 A (this model: 100 A)Harmonic Orders Compensated: 2nd–50thTHD-I Reduction: To <5% (per IEEE 519-2014)Response Time: <0.1 ms
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

LSAHF-100A — LS AHF Active Harmonic Filter

The LS AHF Active Harmonic Filter is an active power conditioning device rated at 30 to 200 A that continuously monitors and compensates harmonic currents from the 2nd to the 50th order, reducing total harmonic distortion (THD-I) at the point of common coupling to below 5% — meeting the limits of IEEE 519-2014, IEC 61000-3-12, and Saudi Electric Company power quality requirements for industrial customers. The LSAHF-100A model provides 100 A of active compensation current, simultaneously handling reactive power compensation and load unbalance correction in addition to harmonic filtering, making it a complete power quality solution in a single compact DIN-rail-mounted or floor-standing enclosure. The filter uses a high-speed DSP control algorithm sampling at 25 kHz to detect harmonic content and inject equal and opposite compensation currents in real time, with compensation response under 0.1 ms — fast enough to handle even rapidly varying harmonic sources such as servo drives and arc furnaces.

The AHF connects in parallel with the non-linear load at the LV distribution bus and requires no modifications to the existing wiring or load equipment, enabling retrofit installation into existing switchboards with minimal downtime. The unit communicates via Modbus RTU for integration with power management systems and provides front-panel measurements of THD before and after compensation, harmonic spectrum display by order, reactive power compensation status, and load unbalance percentage — giving facility engineers real-time visibility of power quality improvement. The unit operates from -10°C to +45°C ambient and is rated for continuous 24/7 service, suitable for installations at data centres, semiconductor fabrication plants, and other facilities requiring constant high power quality.

Harmonic pollution from variable speed drives, UPS systems, switching power supplies, and other non-linear loads is an increasingly critical issue in Saudi Arabian industrial and commercial facilities. SEC power quality standards impose harmonic limits on large commercial and industrial consumers, and violations can result in connection penalties or compulsory mitigation requirements. In facilities with large numbers of variable speed drives — common at desalination plants, pumping stations, and manufacturing facilities — passive harmonic filters tuned to specific frequencies can be detuned by load changes, whereas the AHF's adaptive real-time compensation remains effective regardless of load variation. ARAMCO HSE standards for electrical systems at process facilities increasingly reference IEEE 519 harmonic limits, making the AHF a specified solution for new and retrofit control room power distribution upgrades.

Razz Middle East supplies and commissions LS AHF active harmonic filters for commercial and industrial power quality projects across Saudi Arabia. We provide preliminary harmonic studies using power quality analyser measurements from the customer site to confirm the required filter rating before supply. SAR pricing is available for supply-only or installed turnkey projects, and we offer post-installation measurement reports confirming THD compliance. All LSAHF units carry a two-year warranty with optional extended service contracts for annual calibration and performance verification.

Technical Specifications

Full specifications for the LSAHF-100A

Compensation Current
30–200 A (this model: 100 A)
Harmonic Orders Compensated
2nd–50th
THD-I Reduction
To <5% (per IEEE 519-2014)
Response Time
<0.1 ms
DSP Sampling Rate
25 kHz
Additional Functions
Reactive power, unbalance correction
Communication
Modbus RTU
Ambient Temperature
-10 to +45°C

Key Features & Benefits

  • Compensates harmonic orders 2nd through 50th simultaneously, addressing the full harmonic spectrum from single non-linear load installations to complex multi-source harmonic environments.
  • Reduces THD-I to below 5% at the point of common coupling, meeting IEEE 519-2014 and SEC power quality requirements and avoiding utility harmonic penalty charges.
  • Under 0.1 ms response time with 25 kHz DSP sampling handles rapidly varying harmonic sources including servo drives, arc furnaces, and high-power rectifiers without compensation lag.
  • Simultaneous reactive power compensation and load unbalance correction in a single unit replaces separate PFC capacitor banks and phase balancing equipment in many applications.
  • Parallel connection to existing LV bus requires no modification to load wiring or switchboard configuration, enabling retrofit installation during a single planned maintenance shutdown.
  • Front panel harmonic spectrum display by order and real-time THD measurement provide immediate evidence of power quality improvement for facility managers and utility auditors.

Industrial Applications in Saudi Arabia

  • Large VSD-heavy installations at desalination plants and pumping stations where multiple drives create combined harmonic distortion exceeding SEC limits at the utility metering point.
  • Data centres and server farms where high-density UPS and switch-mode power supply loads create significant 3rd and 5th harmonic currents that cause neutral conductor overheating and transformer losses.
  • Manufacturing facilities with plasma cutters, welding machines, and arc furnaces where rapidly varying non-linear load harmonics require fast-response active compensation rather than fixed passive filters.
  • Hospital and healthcare facility electrical systems where power quality requirements for sensitive medical imaging and life support equipment demand THD levels below 5% at distribution boards.
  • Semiconductor and electronics manufacturing cleanrooms where precision process equipment requires extremely clean power supply to prevent yield loss from power quality disturbances.

Industrial Supplier in Saudi Arabia

Get a Quote for the LS AHF Active Harmonic Filter

We respond within 4 business hours. Send model LSAHF-100A for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — LSAHF-100A

Common questions from buyers in Saudi Arabia and the GCC