100332

Product image coming soon

noark

NOARK Ex9M 3P 63A C-Curve Miniature Circuit Breaker

Model: 100332

Poles: 3PCurrent Rating: 63 ATripping Curve: C (5–10× In)Breaking Capacity: 10 kA at 400 V AC (IEC 60898-1)
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

100332 — NOARK Ex9M 3P 63A C-Curve Miniature Circuit Breaker

The NOARK Ex9M 3P 63A C-Curve Miniature Circuit Breaker (model 100332) is a three-pole IEC 60898-1 / IEC 60947-2 protective device engineered at NOARK's Brno, Czech Republic R&D facility and certified by TÜV to a breaking capacity of 10 kA at 400 V AC three-phase. Operating on the C-curve (5–10× In) magnetic release characteristic, the 63A three-pole rating is the top-of-range MCB commonly used as the main protective device for small distribution sub-panels, motor protection for pumps up to approximately 18.5 kW, and three-phase power outlets in light industrial facilities, workshops, and large commercial kitchens. At 10 kA breaking capacity, the Ex9M 63A handles the prospective fault current levels encountered at the secondary distribution tier of Saudi Arabia's 380 V three-phase network as distributed through SEC-connected low-voltage panels.

The 3-pole configuration and 63 A rating of the Ex9M 100332 make it particularly suited to the Saudi industrial and commercial sector where three-phase loads are ubiquitous — from small air compressors and workshop machinery to three-phase HVAC units, refrigeration compressors, and sub-panel incomers for tenant distribution boards in multi-storey commercial developments. The TÜV certification is a decisive advantage in the ARAMCO and SABIC procurement ecosystem, where the SAPID (Saudi Aramco Product Identification) process requires that protection devices carry third-party certification from a body approved under the ARAMCO approved-vendors framework. NOARK's TÜV documentation satisfies this requirement and has been successfully submitted in multiple ARAMCO facilities management project data packages in the Eastern Province.

Saudi Arabia's Vision 2030 giga-project pipeline — covering NEOM, Qiddiya, The Rig, Red Sea Project, and the expanding King Salman Energy Park (SPARK) in Jubail — creates sustained procurement demand for mid-range quality three-phase MCBs that are fully IEC-certified but commercially competitive versus premium European brands. The NOARK Ex9M 63A 3P fills precisely this requirement: it offers the Czech R&D design heritage and TÜV third-party certification that consulting engineers and ARAMCO/SABIC procurement teams require, while providing the 20–30% cost advantage over premium European alternatives that project cost management teams seek as Vision 2030 projects compete on tight construction budgets. SASO compliance is maintained through the IEC 60898-1 certification basis, which aligns with SASO 2203.

Razz Middle East stocks Ex9M three-pole MCBs locally in Saudi Arabia, supporting panel builders who require urgent delivery for panel manufacture or site replacement. Our technical team can prepare full co-ordination studies and selectivity analyses for mixed-brand panel installations incorporating NOARK Ex9M breakers alongside downstream RCBOs or upstream MCCBs from other manufacturers. We provide Arabic-language conformity declarations and SASO import documentation to support SEC and MOMRA panel approval submissions, and offer on-site training for panel shop teams commissioning NOARK products for the first time.

Technical Specifications

Full specifications for the 100332

Poles
3P
Current Rating
63 A
Tripping Curve
C (5–10× In)
Breaking Capacity
10 kA at 400 V AC (IEC 60898-1)
Voltage
400 V AC (three-phase)
Standard
IEC 60898-1 / IEC 60947-2
Certification
TÜV
Ambient Temperature
-25°C to +55°C

Key Features & Benefits

  • TÜV-certified 10 kA three-phase breaking capacity satisfies ARAMCO SAPID and SABIC panel approval documentation requirements, supporting project data package submissions without local re-testing.
  • Three-pole simultaneous trip mechanism ensures all phases clear on a fault, protecting three-phase motors from dangerous single-phasing conditions in pump and HVAC applications.
  • Czech R&D design pedigree provides a genuine European engineering heritage that consulting engineers and ARAMCO/SABIC procurement committees accept as equivalent to premium European brand specifications.
  • 54 mm three-pole footprint on 35 mm DIN rail fits standard Saudi panel enclosures and is dimensionally compatible with three-pole ABB S203 and Schneider Acti9 3P replacement in existing panels.
  • C-curve magnetic release at 5–10× In provides reliable inrush-tolerant protection for three-phase induction motors, refrigeration compressors, and resistive heating loads without nuisance tripping.
  • Simultaneous trip handle design allows manual three-phase isolation with a single lever operation, meeting SEC switchroom operational safety requirements for visible isolation status.

Industrial Applications in Saudi Arabia

  • Three-phase sub-panel incomer protection in commercial office complexes and retail developments across Riyadh and Jeddah under Vision 2030 commercial real estate programmes, where TÜV certification meets consulting engineer specification requirements.
  • Motor protection for three-phase pumps up to 18.5 kW in ARAMCO and NWC water and utility infrastructure across the Eastern Province, where SAPID-accepted third-party certification is required for panel approval.
  • Three-phase power outlet circuit protection in light industrial workshops and maintenance facilities in MODON industrial parks across the Kingdom, providing reliable fault clearance at SEC network fault levels.
  • HVAC and refrigeration compressor unit protection in hotel kitchens, supermarkets, and large catering facilities serving Vision 2030 tourism and hospitality infrastructure projects.
  • Sub-distribution panel main protection in NEOM ancillary construction facility buildings and temporary camp infrastructure, where Czech R&D quality at mid-range pricing aligns with giga-project cost management targets.
  • Replacement three-pole MCB supply for SEC-registered electrical maintenance contractors across Saudi Arabia, where Ex9M 63A 3P physical compatibility with standard DIN-rail panels simplifies spares inventory.

Industrial Supplier in Saudi Arabia

Get a Quote for the NOARK Ex9M 3P 63A C-Curve Miniature Circuit Breaker

We respond within 4 business hours. Send model 100332 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — 100332

Common questions from buyers in Saudi Arabia and the GCC