Product image coming soon
noark
NOARK Ex9ML 1P+N 25A 30mA RCBO
Model: 110632
4-hour response · Pricing in SAR · Delivery across all KSA regions
110632 — NOARK Ex9ML 1P+N 25A 30mA RCBO
The NOARK Ex9ML 1P+N 25A 30mA RCBO (model 110632) is a dual-function protective device combining 30 mA Class A residual current earth-fault protection with 25 A C-curve thermal-magnetic overcurrent and short-circuit protection in a single compact 1P+N module occupying two 18 mm pole positions on a standard 35 mm DIN rail. Designed at NOARK's R&D centre in Brno, Czech Republic, and certified by TÜV to IEC 61008-1 and IEC 60898-1, the 25 A variant extends the Ex9ML range to cover higher-demand single-phase circuits — particularly air conditioning units, immersion water heaters above 3.5 kW, and dedicated power circuits for catering equipment — where the 16 A rating would be undersized but the load characteristics still require combined RCD and overcurrent protection in a single panel device.
The 25 A rating is calibrated for the split-system and multi-split air conditioning circuits that dominate single-phase electrical loads in Saudi Arabia's residential and hospitality sectors. A typical 12,000–18,000 BTU (1.0–1.5 ton) split-system air conditioner draws 8–12 A in steady-state operation with start-up inrush currents in the 25–40 A range, placing it squarely in the protection zone of a 25 A C-curve RCBO. The Ex9ML 110632 provides simultaneous protection against the electrical shock risk from earth faults in the AC unit's condensate drainage circuit or outdoor unit wiring, and against overload or short-circuit faults in the supply cable — a dual-function that Saudi residential and hotel electrical engineers routinely specify in final circuit design. SASO technical building regulations mandate RCD protection for circuits in wet zones and accessible locations, and the Ex9ML 25A satisfies this requirement in a single compact device.
Saudi Arabia's luxury hospitality sector — driven by Vision 2030's target of 150 million tourist visits annually and the massive hotel construction pipeline from Red Sea Project, Amaala Ultra-Luxury Resort, and the expanded Grand Mosque accommodation zone in Mecca — procures RCBO devices at scale for hotel room and suite distribution boards. A luxury hotel project of 300–500 rooms typically specifies 25 A RCBO-protected circuits for room AC units and bathroom water heating circuits, creating procurement demand for hundreds of units per project. NOARK's Ex9ML 25A provides the TÜV-certified European design quality that five-star hotel project management consultants require in their electrical panel specifications, while offering the cost advantage that giga-project procurement managers are actively seeking as Vision 2030 projects face cost escalation pressures. Razz Middle East's Czech R&D narrative for NOARK allows specification substitution presentations to consulting engineers that are technically credible.
Razz Middle East carries Ex9ML 25A units in local Saudi warehouse stock and can fulfil purchase orders from Riyadh, Jeddah, Dammam, Mecca, Medina, and Jubail within 48 hours. We provide full SASO import documentation, Arabic-language conformity declarations, and circuit co-ordination data sheets to support panel approval submissions to Saudi consulting engineers and SEC distribution network connection teams.
Technical Specifications
Full specifications for the 110632
- Poles
- 1P+N
- Current Rating
- 25 A
- RCD Sensitivity
- 30 mA
- RCD Type
- Class A
- Breaking Capacity
- 6 kA (IEC 60898-1)
- Standard
- IEC 61008-1 / IEC 60898-1
- Certification
- TÜV
- Voltage
- 230 V AC
Key Features & Benefits
- 25 A C-curve thermal-magnetic trip combined with 30 mA Class A RCD in a single 36 mm device provides complete protection for air conditioning and water heating circuits without requiring separate MCB and RCD devices.
- TÜV certification provides independent European attestation accepted in ARAMCO residential compound panel approvals and by Saudi consulting engineers specifying to IEC 60364 and SASO technical building standards.
- Class A residual current sensitivity detects sinusoidal and pulsating DC earth fault components, protecting modern electronic loads including inverter-driven AC units, EV charger control circuits, and LED driver supplies.
- Czech R&D engineering origin from NOARK's Brno facility provides a traceable European design and testing methodology that differentiates the Ex9ML from Chinese-origin alternatives without equivalent third-party certification.
- C-curve inrush tolerance accommodates the 25–40 A start-up inrush of single-phase split-system air conditioning compressors without nuisance tripping while still clearing genuine overcurrent faults within IEC 60898-1 time limits.
- Compact 36 mm two-module footprint allows high circuit density in hotel room and apartment distribution boards, maximising protected circuit count within standard Saudi two-row consumer unit enclosures.
Industrial Applications in Saudi Arabia
- Dedicated air conditioning circuit protection in hotel room and suite distribution boards for Vision 2030 hospitality projects including Red Sea Project, Amaala, and Diriyah Gate, where TÜV certification satisfies five-star project electrical consultant specifications.
- Electric water heater circuit protection in bathroom and service areas of ROSHN affordable housing and ARAMCO residential compound villas across the Kingdom, meeting SASO wet-zone RCD protection requirements.
- Dedicated supply circuit protection for catering equipment, commercial dishwashers, and food service appliances in hotel kitchen and restaurant facilities, where combined overcurrent and earth-fault protection is required by Saudi food service regulations.
- Air conditioning unit protection in ARAMCO-managed office and residential facilities in the Eastern Province, where ARAMCO's facilities maintenance standard requires RCD-grade protection for AC circuits near condensate drainage zones.
- Luxury apartment and villa distribution board circuit protection in PIF-backed residential developments across Riyadh's northern corridors and Jeddah's Obhur waterfront, where Czech R&D quality at mid-tier pricing delivers value to the developer.
- Circuit protection in modular accommodation units for NEOM, ROSHN, and giga-project construction camps across the Kingdom, where space-efficient 36 mm RCBO devices maximise circuit count in compact consumer unit enclosures.
Industrial Supplier in Saudi Arabia
Get a Quote for the NOARK Ex9ML 1P+N 25A 30mA RCBO
We respond within 4 business hours. Send model 110632 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.
Frequently Asked Questions — 110632
Common questions from buyers in Saudi Arabia and the GCC