2838503

Product image coming soon

phoenix-contact

Phoenix Contact VAL-MS 230 AC Surge Protection Device

Model: 2838503

Nominal System Voltage: 230 V ACMax Discharge Current (Imax): 40 kA (8/20 μs)Nominal Discharge Current (In): 20 kA (8/20 μs)Voltage Protection Level (Up): <1.5 kV at In
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

2838503 — Phoenix Contact VAL-MS 230 AC Surge Protection Device

The Phoenix Contact VAL-MS 230 is a DIN-rail-mounted Type 2 surge protection device (SPD) for 230 V AC single-phase circuits, rated at 40 kA (8/20 μs) maximum discharge current and 20 kA (8/20 μs) nominal discharge current (In) with a voltage protection level (Up) of 1.5 kV at In. Designed for installation at the panel power inlet or secondary distribution board level, the VAL-MS 230 provides Type 2 coordination-level protection downstream of the building lightning protection system (Type 1 SPD at main incomer) for all 230 V AC panel power supplies, PLC and DCS equipment power inputs, and motor control equipment in Saudi Arabian industrial and commercial facilities. The VAL-MS uses Phoenix Contact's innovative pluggable insert technology — the SPD varistor module plugs into the base unit and can be replaced in a live panel without disturbing the AC wiring, reducing maintenance downtime in Saudi facilities where planned electrical outages are difficult to schedule during production operations.

The VAL-MS 230 incorporates a thermal disconnect that permanently opens the circuit when the MOV (metal oxide varistor) has absorbed its maximum energy rating or overheated — preventing the well-documented failure mode of degraded MOV continued conduction at mains voltage, which can lead to panel overheating and fire in unmonitored Saudi field installations. The status indicator window changes from green (SPD functional) to red (SPD requires replacement) when the thermal disconnect operates, enabling maintenance inspection without instrumentation. A remote signalling contact (volt-free NC contact) reports SPD status to the building management system or DCS, enabling automated maintenance alarms in Saudi facilities with remote monitoring capability. The VAL-MS 230 meets IEC 61643-11 Type 2 classification and EN 50539-11 for photovoltaic (PV) system applications, making it the appropriate choice for both conventional AC panel protection and the rapidly growing Saudi solar energy sector under Vision 2030.

Lightning-induced power-line surges are a significant risk to Saudi industrial panel equipment — particularly in the flat open-desert terrain of the Eastern Province, where the absence of natural shielding and the extensive overhead medium-voltage distribution network create a high exposure to cloud-to-ground and cloud-to-cloud lightning-induced EMF transients. Saudi Aramco operating experience has shown that unprotected PLC and DCS equipment in field panels and remote substations is vulnerable to power-line surges that arrive from the SEC grid via the transformer secondary, bypass the panel main MCB (which is too slow to respond to a microsecond surge), and damage PLC power supply switching transistors and DCS I/O module bus driver ICs. The VAL-MS 230 installed at the 230 V AC input to each field panel power supply provides the Type 2 coordination-level protection required by IEC 62305-4 and ARAMCO GI-0476 to limit the surge voltage seen by the panel equipment.

Razz Middle East stocks VAL-MS in 120 V AC, 230 V AC, and 400 V AC 3-phase variants in Riyadh and Jeddah, with the pluggable replacement inserts stocked separately for the convenience of Saudi maintenance teams. We provide SPD coordination studies per IEC 62305-4 and ARAMCO GI-0476 — confirming the correct combination of Type 1 (main incomer), Type 2 (sub-board entry), and Type 3 (point of use) SPDs for each Saudi panel installation, and verifying that the SPD voltage protection level (Up) is lower than the equipment's withstand voltage (Uw) at each protection level. All VAL-MS 230 supplies include Phoenix Contact CE declarations, IEC 61643-11 test reports, and SASO import conformity documentation.

Technical Specifications

Full specifications for the 2838503

Nominal System Voltage
230 V AC
Max Discharge Current (Imax)
40 kA (8/20 μs)
Nominal Discharge Current (In)
20 kA (8/20 μs)
Voltage Protection Level (Up)
<1.5 kV at In
Insert Type
Pluggable replaceable
Status Indicator
Green/Red window
Remote Signalling
Volt-free NC contact
Standard
IEC 61643-11 Type 2

Key Features & Benefits

  • Pluggable replaceable insert allows SPD varistor module replacement in a live 230 V AC panel without disturbing wiring — minimising Saudi production facility downtime.
  • 40 kA / 20 kA In discharge rating and Up < 1.5 kV provides Type 2 coordination-level protection meeting IEC 62305-4 and ARAMCO GI-0476 requirements.
  • Thermal disconnect permanently opens degraded MOV circuit, preventing the MOV sustained-conduction failure mode that causes panel overheating and fire in unmonitored Saudi field panels.
  • Green/Red status window enables quick maintenance inspection without instrumentation; volt-free NC remote-signalling contact reports SPD status to DCS or BMS for automated alarms.
  • Meets IEC 61643-11 Type 2 and EN 50539-11 PV application standard — suitable for both conventional Saudi industrial panel protection and Vision 2030 solar energy installations.
  • Protects against power-line surges transiting the SEC grid MV/LV transformer secondary that bypass the panel MCB and damage PLC power supply transistors and DCS I/O bus drivers.

Industrial Applications in Saudi Arabia

  • 230 V AC Type 2 SPD at power supply inlet of ARAMCO field panels and remote substation panels subject to SEC grid lightning-induced surges in the flat Eastern Province terrain.
  • PLC and DCS equipment power input protection in SABIC Jubail and Yanbu process-area panels exposed to overhead LV distribution lightning transients.
  • 230 V AC panel power supply surge protection for NEOM smart-city infrastructure panels in outdoor and semi-outdoor enclosures across Sharma, Sindalah, and OXAGON.
  • Solar inverter AC output surge protection for Vision 2030 utility-scale and rooftop PV installations per EN 50539-11 requirement.
  • AC incomer surge protection for SEC grid SCADA RTU and smart-metering panel 230 V AC power supplies in exposed outdoor substation locations.
  • Type 2 SPD coordination at 230 V AC sub-board entry for SWCC desalination and NWC pumping station electrical room panel protection systems.

Industrial Supplier in Saudi Arabia

Get a Quote for the Phoenix Contact VAL-MS 230 AC Surge Protection Device

We respond within 4 business hours. Send model 2838503 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — 2838503

Common questions from buyers in Saudi Arabia and the GCC