Schneider Electric PowerLogic PM8000 Advanced Power Quality Meter — PM8243

schneider-electric

Schneider Electric PowerLogic PM8000 Advanced Power Quality Meter

Model: PM8243

Accuracy Class: 0.2S (highest utility grade)Harmonics: Up to 63rd + inter-harmonics + sub-harmonicsFlicker: Pst, Plt, Pinst measurementWaveform Capture: 256 samples/cycle continuous
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

PM8243 — Schneider Electric PowerLogic PM8000 Advanced Power Quality Meter

The Schneider Electric PowerLogic PM8000 is an advanced power quality and energy meter combining revenue-grade Class 0.2S energy measurement with the most comprehensive power quality monitoring capability available in a panel-mount instrument, covering the full IEC 61000-4 series power quality measurement requirements in a single instrument without external signal conditioning. The PM8000 measures voltage and current harmonics to the 63rd order, inter-harmonics, sub-harmonics, flicker (Pst, Plt, Pinst), voltage unbalance, frequency variation, rapid voltage changes (RVC), and transient voltage events — providing a complete picture of network power quality that identifies both the impact of equipment on the supply and the impact of supply quality on equipment.

The PM8000's waveform capture capability records voltage and current waveforms at up to 256 samples per cycle continuously, storing triggered event captures in internal memory for post-event analysis — enabling root cause investigation of equipment malfunctions, process trips, and production quality incidents that are caused by power supply disturbances. The meter's IEC 61850 communication capability enables direct integration into substation automation systems, while the optional power quality cellular modem card supports remote access to power quality data at unstaffed locations including remote pump stations and solar farm grid connection points. Class 0.2S energy measurement satisfies the highest tier of utility billing accuracy requirements.

In Saudi Arabia, the PM8000 KSA addresses the growing need for power quality monitoring at both utility substation and industrial facility level. SEC's distribution network management requires power quality monitoring at customer connection points to identify harmonic injection and manage voltage flicker complaints under the Saudi grid code. ARAMCO's facility management programmes specify PM8000 for critical equipment power supply monitoring where PQ events are the suspected root cause of process instrumentation malfunctions. NEOM's smart grid infrastructure uses PM8000 as the primary power quality monitoring instrument at all distribution substations.

Razz Middle East supplies PM8000 meters with full EcoStruxure PME integration configuration, IEC 61850 object mapping, and PQ monitoring programme setup for utility and industrial power quality monitoring projects across Saudi Arabia.

Technical Specifications

Full specifications for the PM8243

Accuracy Class
0.2S (highest utility grade)
Harmonics
Up to 63rd + inter-harmonics + sub-harmonics
Flicker
Pst, Plt, Pinst measurement
Waveform Capture
256 samples/cycle continuous
Communication
Ethernet + IEC 61850 + Modbus
PQ Events
RVC, transients, voltage sags/swells
Optional
Cellular modem for remote monitoring
Standard
IEC 61000-4-30 Class A

Key Features & Benefits

  • Class 0.2S energy measurement accuracy — the highest utility billing grade — satisfies Saudi grid code metering requirements for IPP export settlement and large industrial customer billing reconciliation.
  • IEC 61000-4-30 Class A power quality compliance covers the full measurement requirement set for connection point power quality assessment under SEC's network code, eliminating additional instrumentation.
  • Waveform capture at 256 samples per cycle with event-triggered storage enables post-event root cause analysis of process trips and equipment malfunctions caused by power supply disturbances.
  • Inter-harmonic measurement identifies non-integer frequency components from cycloconverters, arc furnaces, and wind turbine generators that standard harmonic meters do not detect, providing complete PQ characterisation.
  • IEC 61850 communication enables direct integration into substation automation systems at SEC distribution substations and industrial plant protection panels without a Modbus-IEC 61850 protocol converter.
  • Optional cellular modem card provides remote access to power quality data at unstaffed locations including remote pump stations, wind farms, and solar grid connection points across Saudi Arabia's dispersed infrastructure.
  • EcoStruxure Power Monitoring Expert integration with automatic PQ trend report generation provides facility managers and SEC network operators with scheduled PQ compliance reports without manual data export.

Industrial Applications in Saudi Arabia

  • SEC distribution substation power quality monitoring for harmonic and flicker assessment at large industrial customer connection points, where Grid Code compliance requires IEC 61000-4-30 Class A measurement.
  • ARAMCO facility critical instrument power supply quality monitoring, where PM8000 waveform capture identifies power quality events causing instrumentation malfunctions in process control systems.
  • NEOM smart grid distribution substation PQ instrumentation, where PM8000 provides the power quality baseline data required for the city's electricity network performance monitoring and reporting.
  • Large arc furnace and electrolyser facility grid impact monitoring at steel and aluminium production facilities in Jubail and Ras Al Khair, where IEC 61000-3-12 harmonic injection assessment is required.
  • REPDO solar and wind farm grid connection point PQ monitoring for grid code compliance and export metering, where cellular modem remote access eliminates staffing costs at remote desert and coastal sites.
  • Pharmaceutical and semiconductor facility critical power supply quality monitoring, where PM8000 waveform records provide evidence for equipment warranty claims and FDA process validation deviation reports.
  • Data centre utility supply quality monitoring in Riyadh and Jeddah hyperscale facilities, where voltage sag and swell event capture supports UPS performance validation and generator transfer time studies.

Industrial Supplier in Saudi Arabia

Get a Quote for the Schneider Electric PowerLogic PM8000 Advanced Power Quality Meter

We respond within 4 business hours. Send model PM8243 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — PM8243

Common questions from buyers in Saudi Arabia and the GCC