Siemens SIRIUS 3RU Thermal Overload Relay — 3RU2126-4AB0

siemens

Siemens SIRIUS 3RU Thermal Overload Relay

Model: 3RU2126-4AB0

Current Range: 0.1–100 A (adjustable)Trip Class: Class 10A (IEC 60947-4-1)Phase Failure: Detected within 3–10 sAmbient Compensation: Bimetallic self-compensating
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

3RU2126-4AB0 — Siemens SIRIUS 3RU Thermal Overload Relay

The Siemens SIRIUS 3RU thermal overload relay is the standard motor protection device in Saudi Arabia's SIRIUS motor starter assemblies, providing reliable protection against thermal overload, phase failure, and phase asymmetry in a compact unit that clips directly onto the corresponding 3RT contactor without additional mounting hardware or inter-device wiring. This direct-mounting interface — the 3RU snaps onto the 3RT's base in a single action and the main current path is made through the contactor's mechanical interface — is the feature that most distinguishes the SIRIUS system from conventional separate-mount overload relay installations, reducing assembly time on large MCC projects by up to 25% and eliminating the potential wiring errors associated with separate terminal connections.

The 3RU uses bimetallic thermal elements that provide ambient temperature compensation — when the ambient temperature in the panel rises above the calibration reference (20°C), the bimetallic element automatically adjusts its trip threshold downward, protecting the motor against the additional thermal stress imposed by high ambient conditions. This self-compensating characteristic is especially important in Saudi Arabia where panel temperatures in outdoor MCCs can reach 50°C or above during summer months, conditions where a non-compensating relay would allow chronic motor overloading. The 3RU also provides phase failure sensitivity that detects single-phasing within 3–10 seconds, tripping before the motor's thermal model accumulates sufficient heat to cause winding damage — a critical protection function given that phase failure is one of the most common causes of motor burnout in the Kingdom.

The 3RU2 current range spans 0.1 A to 100 A, covering motors from fractional-kilowatt single-phase auxiliaries through to 45 kW three-phase process motors, with Class 10A trip characteristic as standard for general industrial motor applications. Manual and automatic reset options allow facility operators to choose whether the starter locks out after a trip (manual — requiring operator attention before restart) or automatically resets after the thermal element cools (automatic — useful for remote unattended pump stations). Both reset modes are selectable on the installed relay without tools, providing operational flexibility across different site management philosophies.

Razz Middle East supplies 3RU overload relays in all current settings from 0.1 A to 100 A for immediate delivery throughout Saudi Arabia, matched to the corresponding 3RT contactor sizes for complete starter assembly supply to panel builders and industrial maintenance teams.

Technical Specifications

Full specifications for the 3RU2126-4AB0

Current Range
0.1–100 A (adjustable)
Trip Class
Class 10A (IEC 60947-4-1)
Phase Failure
Detected within 3–10 s
Ambient Compensation
Bimetallic self-compensating
Reset
Manual / automatic (field selectable)
Mounting
Direct clip-on to 3RT contactor
Auxiliary Contacts
1 NC trip + 1 NO signal
Standard
IEC 60947-4-1

Key Features & Benefits

  • Direct clip-on mounting to corresponding 3RT contactor without inter-device wiring eliminates separate terminal connections, reducing MCC assembly time by up to 25% on large motor starter projects.
  • Bimetallic ambient temperature self-compensation automatically adjusts the thermal trip threshold as panel temperature rises, protecting motors from chronic overloading in Saudi Arabia's outdoor MCCs where summer temperatures exceed 50°C.
  • Phase failure detection trips within 3–10 seconds of single-phasing, preventing motor winding damage before the thermal model accumulates sufficient heat — critical protection against one of the most common motor burnout causes in the Kingdom.
  • Manual and automatic reset modes are field-selectable on the installed relay without tools, allowing operators to choose lockout-after-trip for safety-critical pumps or automatic recovery for unattended remote pump stations.
  • Adjustable current setting dial covers each relay's full current range continuously, allowing precise setting to the motor's nameplate full-load current without stocking multiple fixed-rating relays for each motor size.
  • 1NC trip contact and 1NO signal contact are standard on all 3RU relays, providing both circuit break and alarm signal outputs without additional auxiliary contact blocks.
  • Test button on the relay face allows functional testing of the trip and reset circuit during commissioning and maintenance without running the motor to thermal trip point, satisfying ARAMCO and SABIC maintenance procedure requirements.

Industrial Applications in Saudi Arabia

  • SIRIUS motor starter assemblies in ARAMCO-approved MCCs at processing and utility facilities in the Eastern Province, where 3RU clip-on mounting to 3RT contactors is the standard thermal overload protection method in SEC-approved panel builder assemblies.
  • Pump motor protection in NWC water booster stations, where the automatic reset option allows unattended pump restoration after a thermal trip caused by momentary supply voltage reduction during peak demand periods.
  • Fan and HVAC motor protection in commercial buildings and industrial facilities, where ambient temperature compensation prevents nuisance tripping in hot plant rooms while maintaining protection sensitivity for genuine overload conditions.
  • Conveyor belt and material handling motor protection at cement and aggregate processing facilities, where phase failure detection protects expensive high-torque motors from the single-phasing that frequently follows fuse failure in high-dust environments.
  • Process pump motor protection in SABIC petrochemical plant process areas, where manual reset enforces operator attendance before restart — a safety procedure required by the facility's motor management protocol for critical process pumps.
  • Compressor motor protection in industrial utility systems across the Kingdom, where the 3RU's Class 10A trip class accommodates the extended high-current starting characteristic of direct-on-line compressor starting without nuisance tripping.
  • Replacement overload relay installations in existing SIRIUS starter panels across Saudi Arabia's ageing industrial infrastructure, where the 3RU's clip-on interface allows direct like-for-like replacement without panel rewiring.

Industrial Supplier in Saudi Arabia

Get a Quote for the Siemens SIRIUS 3RU Thermal Overload Relay

We respond within 4 business hours. Send model 3RU2126-4AB0 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — 3RU2126-4AB0

Common questions from buyers in Saudi Arabia and the GCC