Siemens 5SV RCCB Residual Current Device
Model: 5SV3342-6
4-hour response · Pricing in SAR · Delivery across all KSA regions
5SV3342-6 — Siemens 5SV RCCB Residual Current Device
The Siemens 5SV residual current circuit breaker (RCCB) provides life-safety protection against electric shock and the risk of electrical fire caused by residual earth leakage currents — the two failure modes that thermal-magnetic MCBs cannot detect because they respond only to overload and short-circuit, not to the small ground-fault currents that cause electrocution. The 5SV covers rated load currents from 25 A to 125 A in four sensitivity levels (10 mA, 30 mA, 100 mA, 300 mA) and three current types: Type AC for sinusoidal earth leakage from conventional loads; Type A for loads that produce pulsating DC leakage currents (variable speed drives, electronic equipment, LED drivers, EV chargers); and Type F for loads generating high-frequency leakage currents from switched-mode power supplies and three-phase drives.
The 30 mA sensitivity level is the international standard for personal shock protection, based on IEC 60479 research showing that 30 mA is below the cardiac fibrillation threshold for most healthy adults. Saudi Arabia's updated electrical installation standards increasingly mandate 30 mA RCD protection for socket outlets in bathrooms, kitchens, outdoor areas, and all circuits where water or moisture is present — installations where electrocution risk from fault-to-earth on metal equipment casings is statistically most likely. The 5SV's high immunity to nuisance tripping from transient earth leakage currents associated with motor starting, capacitor discharge equipment, and large electronic load switching reduces operational disruptions in facilities where false tripping causes significant inconvenience or safety risk.
In Saudi Arabia, the 5SV RCCB is increasingly mandated in new residential and commercial construction as the Saudi Building Code and SEC electrical installation requirements align with international IEC 60364 RCD protection standards. Residential compound developments in Riyadh and Jeddah specify Type A 5SV RCCBs on all socket outlet circuits to address the growing density of variable speed drives, LED lighting, and EV charging points that generate pulsating DC leakage. Hotels, hospitals, and commercial facilities specify Type F RCCBs on circuits serving conference AV equipment, data centre UPS systems, and HVAC variable speed drives where high-frequency leakage would cause nuisance tripping on conventional Type AC devices.
Razz Middle East stocks 5SV RCCBs in all current ratings, sensitivities, types, and pole configurations (2P/4P) for immediate delivery to panel builders, electrical contractors, and project sites throughout Saudi Arabia, with technical advice on Type selection and sensitivity coordination for complex protection schemes.
Technical Specifications
Full specifications for the 5SV3342-6
- Rated Current
- 25–125 A
- Sensitivity
- 10 mA / 30 mA / 100 mA / 300 mA
- Current Types
- AC (sinusoidal) / A (pulsating DC) / F (high frequency)
- Voltage
- 230/400 V AC
- Poles
- 2P / 4P
- Response Time
- <300 ms (general), <40 ms (S-type selective)
- Mounting
- DIN rail TS35
- Standard
- IEC 61008-1
Key Features & Benefits
- Three current type variants — AC, A, and F — cover all earth leakage waveform types from simple sinusoidal faults through pulsating DC from electronic equipment to high-frequency leakage from switched-mode power supplies and three-phase VFDs.
- 30 mA sensitivity level provides personal shock protection at the IEC 60479 threshold for cardiac fibrillation, satisfying Saudi Building Code requirements for socket outlet and bathroom circuit protection in residential and commercial buildings.
- High immunity to nuisance tripping from transient earth leakage associated with motor starting, capacitor discharge equipment, and electronic load switching reduces operational disruptions in facilities where false trips cause safety or production risks.
- Type A devices protect circuits with variable speed drives, LED lighting, EV charging equipment, and other electronics that produce pulsating DC leakage currents undetectable by conventional Type AC RCCBs.
- Selective (S-type) variants with 40–200 ms intentional response delay allow upstream-downstream protection coordination between main RCCB and branch RCCBs, isolating only the faulted circuit rather than de-energising the entire distribution board.
- Test button functional verification can be performed with the circuit energised and loaded, allowing regular safety testing per IEC 61008 recommendations without requiring circuit shutdown or load disconnection.
- 2P configuration for single-phase circuits and 4P configuration for three-phase circuits from the same product series simplify procurement and stocking for panel builders assembling mixed single-phase and three-phase distribution boards.
Industrial Applications in Saudi Arabia
- Residential villa and apartment socket outlet circuit protection in Saudi Arabia's major housing developments, where Type A 30 mA 5SV RCCBs address the increasing density of VFDs, LED drivers, and EV chargers producing pulsating DC leakage.
- Bathroom, kitchen, and outdoor circuit RCD protection in commercial buildings and hotels, where 30 mA sensitivity satisfies Saudi Building Code mandatory RCD requirements for circuits in areas with water or moisture presence.
- EV charging point circuit protection in commercial car parks and residential compounds, where Type A 5SV devices detect the DC leakage currents produced by EV on-board chargers that conventional Type AC devices cannot monitor.
- Hospital patient care area circuit protection, where 10 mA sensitivity satisfies IEC 60364-7-710 requirements for medical locations where patients with reduced electrical resistance (via medical equipment) face elevated shock risk.
- Data centre and server room distribution board protection, where Type F 5SV devices handle high-frequency leakage from UPS systems and switched-mode power supply banks without nuisance tripping that would cause IT service disruption.
- Industrial facility welfare and canteen area protection at petrochemical and manufacturing sites, where mandatory RCD protection on kitchen equipment circuits satisfies ARAMCO and SABIC site electrical safety management requirements.
- Commercial kitchen and restaurant circuit protection in hotels and food service establishments across the Kingdom, where 30 mA Type A protection addresses the mixed conventional and variable-speed equipment loads on kitchen distribution boards.
Industrial Supplier in Saudi Arabia
Get a Quote for the Siemens 5SV RCCB Residual Current Device
We respond within 4 business hours. Send model 5SV3342-6 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.
Frequently Asked Questions — 5SV3342-6
Common questions from buyers in Saudi Arabia and the GCC
More siemens Products
Siemens 3NX8 NH Fuse Switch Disconnector
3NX8012
Siemens 3TF / 3TB Legacy Contactor Spare Parts
3TF4422-0AP0
Siemens 5SL Miniature Circuit Breaker
5SL6116-7
Siemens 5SM3 Residual Current Monitor (RCM)
5SM3618-0
Siemens 5ST3 Modular Load Break Switch
5ST3014
Siemens 5SY MCB + 5SV RCD Consumer Unit Board
5SY6116-7+5SV3612-6