5SY6116-7+5SV3612-6 — Siemens 5SY MCB + 5SV RCD Consumer Unit Board

The Siemens 5SY MCB and 5SV RCCB consumer unit board is the coordinated overcurrent and residual current protection assembly for residential and commercial final distribution circuits — a pre-engineered, pre-wired combination of Siemens 5SL miniature circuit breakers and 5SV residual current circuit breakers assembled into a complete ready-to-install distribution board that provides both branch circuit overcurrent protection and earth leakage life-safety protection from a single Siemens product family. The 5SY MCB provides thermal-magnetic protection per IEC 60898-1 against overload and short-circuit on each final circuit, with B-curve characteristics (3–5× In instantaneous trip) for resistive lighting and socket circuits and C-curve (5–10× In) for motor and HVAC equipment loads. The 5SV RCCB upstream of the MCB groups provides Type A residual current protection at 30 mA — the internationally recognised threshold below the cardiac fibrillation level per IEC 60479 — protecting all circuits in the group against earth leakage from both sinusoidal and pulsating DC fault currents, the latter being generated by variable speed drives, LED lighting drivers, and EV charging equipment increasingly common in Saudi buildings.

The technical advantage of sourcing MCBs and RCCBs from the same Siemens 5-series range is verified protection coordination: Siemens publishes tested coordination tables confirming that the 5SY MCB's let-through energy (I²t) at the rated RCCB current does not damage the 5SV at the point of fault isolation, and that the 5SV's 30 mA trip threshold remains accurate after operation of upstream MCBs — coordination data frequently unavailable when MCBs and RCCBs are mixed from different manufacturers. Pre-assembly by Razz Middle East eliminates on-site panel assembly errors, reduces electrical contractor installation time, and provides a tested board with circuit labelling and inspection documentation ready for the Saudi SASO electrical inspection process.

In Saudi Arabia, the Siemens 5SY and 5SV consumer unit board is the standard distribution protection assembly for villa compound residential developments in Riyadh's northern suburbs, apartment tower distributions in Jeddah's waterfront projects, and commercial fit-out distribution boards for retail and F&B tenants across the Kingdom. National Housing Company (NHC) and ROSHN residential megaproject contractors specify Siemens coordinated consumer units for new homes under Vision 2030's housing targets, valuing the SASO-approved 5SY product compliance and Siemens brand quality familiar to Saudi electrical inspectors. Commercial contractors fitting out Red Sea Project resort facilities and NEOM Sindalah Island spaces use Razz pre-assembled boards that arrive tested, labelled, and ready to terminate.

Razz Middle East assembles 5SY MCB and 5SV RCCB consumer unit boards to customer specifications in 4-way to 24-way configurations, with custom circuit labelling, Type A or Type F RCCB specification, and B or C curve MCB selection. We deliver assembled and tested boards throughout Saudi Arabia with 4-hour RFQ response and SAR pricing.

Technical Specifications

Full specifications for the 5SY6116-7+5SV3612-6

MCB Type
5SL (5SY) series, B and C trip characteristics
RCCB Type
5SV Type A (30 mA standard, 10/100/300 mA options)
Circuit Ways
4, 8, 12, 16, 20, 24-way configurations
Voltage
230/400 V AC
Breaking Capacity
6 kA (5SL4) / 10 kA (5SL6)
Board Enclosure
Siemens flush-mount or surface-mount distribution board
Coordination
Tested and verified per IEC 61009-1
Assembly
Pre-wired and tested by Razz Middle East

Key Features & Benefits

  • Verified coordination between 5SY MCBs and 5SV RCCBs using Siemens tested I²t tables confirms upstream RCCB integrity after downstream MCB fault operation — coordination data unavailable when mixing brands from different manufacturers.
  • Type A RCCB protection detects both sinusoidal and pulsating DC earth leakage currents produced by LED lighting drivers, VFDs, and EV charging equipment increasingly standard in Saudi residential and commercial buildings.
  • 30 mA RCCB sensitivity provides personal shock protection at the IEC 60479 cardiac fibrillation threshold, satisfying Saudi Building Code mandatory RCD requirements for bathroom, kitchen, outdoor, and all socket outlet circuits.
  • Pre-assembly and testing by Razz Middle East eliminates on-site panel wiring errors, reduces electrical contractor site installation time, and delivers a tested and labelled board ready for SASO electrical inspection without on-site assembly verification.
  • Custom configuration from 4-way to 24-way with customer-specified circuit labelling, B or C curve MCB selection, and Type A or Type F RCCB selection provides a tailored board matching the building's specific circuit layout from a single order.
  • SASO-approved 5SL MCB and 5SV RCCB products ensure Saudi Standards Authority inspection compliance without additional certification documentation for building handover and occupancy approval.
  • Same-manufacturer MCB and RCCB selection simplifies post-installation technical support, warranty resolution, and spare component sourcing from Razz Middle East's local stock compared to split-brand boards requiring two suppliers for maintenance.

Industrial Applications in Saudi Arabia

  • Residential villa consumer unit final circuit protection for NHC and ROSHN housing megaproject developments across Saudi Arabia, where pre-assembled tested boards accelerate electrical installation and SASO inspection timescales.
  • Apartment tower distribution board final circuit protection in Jeddah waterfront and Riyadh northern district residential developments, where Type A 30 mA RCCB satisfies Saudi Building Code mandatory earth fault protection requirements.
  • Commercial retail and F&B tenant fit-out distribution boards in shopping malls across the Kingdom, where pre-assembled boards reduce fit-out contractor installation time and provide verified protection coordination documentation for mall operator approval.
  • Red Sea Project resort villa and hotel room distribution boards, where Siemens pre-assembled boards deliver consistent brand quality and SASO compliance across all accommodation units in the resort portfolio.
  • NEOM Sindalah Island and The Line residential distribution boards, where pre-assembled tested boards satisfy the projects' quality management system requirements for electrical installation documentation and material traceability.
  • Hotel guestroom and corridor distribution panels for major hotel developments in Makkah and Madinah, where pre-assembled boards reduce installation time during the critical construction phases of Holy Cities hospitality projects.
  • Light industrial unit and small workshop distribution boards in MODON industrial estates, where C-curve MCBs on motor and HVAC circuits and B-curve on lighting and socket circuits provide correct protection without on-site curve selection errors.

Industrial Supplier in Saudi Arabia

Get a Quote for the Siemens 5SY MCB + 5SV RCD Consumer Unit Board

We respond within 4 business hours. Send model 5SY6116-7+5SV3612-6 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — 5SY6116-7+5SV3612-6

Common questions from buyers in Saudi Arabia and the GCC