
siemens
Siemens SIRIUS 3RV Motor Protection Circuit Breaker
Model: 3RV2011-1DA10
4-hour response · Pricing in SAR · Delivery across all KSA regions
3RV2011-1DA10 — Siemens SIRIUS 3RV Motor Protection Circuit Breaker
The Siemens SIRIUS 3RV motor protection circuit breaker is the combined motor protection and switching device that replaces the separate MCCB or fuse plus overload relay in direct-on-line motor starter circuits — consolidating short-circuit protection, thermal overload protection, and manual on/off switching into a single DIN-rail or contactor-mounted device rated for 0.1 A to 100 A across four frame sizes (3RV2011, 3RV2021, 3RV2031, 3RV2041). The 3RV's thermal-magnetic trip mechanism provides Class 10 (IEC 60947-4-1) thermal overload protection against sustained overloads, with a continuously adjustable current setting dial that allows the field electrician to match the relay precisely to the motor's nameplate full-load current — unlike fixed-rating fuses that require stocking multiple fuse values. The magnetic instantaneous trip provides short-circuit clearing at currents from 7× to 14× the current setting depending on the 3RV type, and the breaking capacity reaches 100 kA at 415 V AC in the 3RV2031 and 3RV2041 sizes, covering the fault current levels encountered at busbars of industrial MCCs supplied by large distribution transformers in Saudi Arabia.
The 3RV's defining integration feature is its direct-clip-on mounting interface with Siemens SIRIUS 3RT contactors: the 3RV mounts directly onto the base of the corresponding 3RT contactor without separate mounting hardware, and the main current path passes through the mechanical interface — eliminating the separate wiring run from the breaker to the contactor that conventional circuit breaker and contactor combinations require. The 3RV also provides auxiliary contacts (1 NO + 1 NC) for remote tripped-status monitoring in PLC-controlled motor starter panels, and the integral hand-wheel operator on the 3RV2031 and 3RV2041 allows the motor starter to be isolated manually from the front panel without a separate isolating switch. Alarm signalling contact add-ons and remote operator accessories extend the 3RV into motor management system architectures where trip events must be reported to a centralised maintenance management platform.
In Saudi Arabia, the SIRIUS 3RV is the standard motor protection circuit breaker in SIRIUS direct-on-line motor starter assemblies throughout ARAMCO refinery and utility MCCs, SABIC petrochemical plant motor control centres, NWC water pumping station panels, and industrial MCCs across MODON industrial estates in Riyadh, Jeddah, and Dammam. The 3RV's direct mounting to the 3RT contactor and 3RU overload relay direct-mount alternative makes it the essential component for Siemens SIRIUS motor starter modules assembled by SEC-approved panel builders in the Kingdom. For motors above 45 kW where an overload relay is preferred over a motor protection circuit breaker, the 3RV provides the main circuit short-circuit protection function with a 3RT contactor and 3RU2 overload relay completing the starter assembly.
Razz Middle East stocks SIRIUS 3RV motor protection circuit breakers across the full 0.1 A to 100 A range in all four frame sizes for immediate delivery to panel builders, industrial contractors, and maintenance teams throughout Saudi Arabia. We provide 4-hour RFQ response with SAR pricing and same-day dispatch from our local warehouse.
Technical Specifications
Full specifications for the 3RV2011-1DA10
- Current Range
- 0.1–100 A (adjustable dial)
- Frame Sizes
- 3RV2011 (0.1–16 A), 3RV2021 (1.8–16 A), 3RV2031 (10–100 A), 3RV2041 (10–100 A)
- Voltage
- Up to 690 V AC
- Breaking Capacity
- Up to 100 kA at 415 V AC
- Trip Class
- Class 10 (IEC 60947-4-1)
- Mounting
- Direct clip-on to 3RT contactor or DIN rail
- Auxiliary Contacts
- 1 NO + 1 NC (standard)
- Standard
- IEC 60947-2 / IEC 60947-4-1
Key Features & Benefits
- Continuously adjustable current setting dial allows field matching to the motor's exact nameplate full-load current across the full frame range without stocking multiple fixed-rating devices, reducing panel assembly errors and maintenance inventory.
- Direct clip-on mounting to corresponding 3RT contactor eliminates separate mounting hardware and inter-device wiring, creating a compact motor starter assembly with a mechanically integrated protection-and-switching unit in less panel space than separate components.
- Breaking capacity up to 100 kA at 415 V AC in the 3RV2031 and 3RV2041 sizes covers the highest prospective short-circuit currents at MCC busbars supplied by large distribution transformers at ARAMCO, SABIC, and major industrial facilities.
- Class 10 thermal overload protection per IEC 60947-4-1 provides fast trip response to sustained motor overloads while tolerating the 6–8× full-load current inrush of direct-on-line starting without nuisance tripping — the critical balance for Saudi industrial motor protection.
- Integrated auxiliary contacts (1 NO + 1 NC) provide remote tripped-status monitoring in PLC-controlled motor starter panels, allowing centralised maintenance management systems to log motor protection events without additional auxiliary contact blocks.
- Phase failure sensitivity detects single-phasing within seconds of fuse failure or loose terminal, tripping the motor before it overheats on two phases — particularly important in Saudi outdoor panel installations where terminal corrosion increases contact failure frequency.
- Alarm contact add-on and remote operator accessories extend the 3RV into motor management system architectures where trip events must be reported to ARAMCO and SABIC maintenance CMMS platforms for preventive maintenance planning.
Industrial Applications in Saudi Arabia
- Direct-on-line motor starter short-circuit and overload protection at ARAMCO-approved MCCs in Eastern Province process and utility facilities, where 3RV clip-on mounting to 3RT contactors is the ARAMCO-standard motor starter assembly configuration.
- Pump motor protection in SIRIUS starter panels at NWC water booster stations and SWCC desalination pre-treatment pump systems, where phase failure detection protects pump motors at unmanned remote stations from single-phasing damage.
- Fan and conveyor motor protection at SABIC Jubail petrochemical plant utility areas, where 3RV Class 10 protection accommodates the extended starting current of large fan motors without nuisance tripping during frequent start cycles.
- Motor feeder short-circuit protection in industrial MCCs at MODON industrial estate factories, where 3RV's 100 kA breaking capacity at 415 V covers the fault current levels at transformer secondary busbars in Saudi industrial substations.
- HVAC air handling unit and cooling tower fan motor starter protection at commercial buildings across Riyadh and Jeddah, where 3RV combined protection-and-switching eliminates separate isolator and overload relay components, reducing panel assembly cost.
- Compressor motor protection in Saudi industrial utility systems, where adjustable current setting dial and Class 10 trip class accommodate both the high starting current of direct-on-line compressor starting and precise full-load current trip protection.
- Replacement motor protection device installations at existing Saudi industrial MCCs, where 3RV's clip-on contactor interface enables like-for-like replacement of worn or damaged motor protection devices without panel rewiring.
Industrial Supplier in Saudi Arabia
Get a Quote for the Siemens SIRIUS 3RV Motor Protection Circuit Breaker
We respond within 4 business hours. Send model 3RV2011-1DA10 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.
Frequently Asked Questions — 3RV2011-1DA10
Common questions from buyers in Saudi Arabia and the GCC