weg
WEG AHF Active Harmonic Filter
Model: AHF-100A
4-hour response · Pricing in SAR · Delivery across all KSA regions
AHF-100A — WEG AHF Active Harmonic Filter
The WEG AHF Active Harmonic Filter is a power electronics-based harmonic mitigation system rated from 30 A to 300 A per unit (expandable to 1,200 A via parallel units), designed to reduce total harmonic current distortion (THDI) from non-linear loads — variable frequency drives, UPS systems, switch-mode power supplies, and arc furnaces — to below 5% THD at the point of common coupling, meeting IEEE 519-2014 and IEC 61000-3-2/4 harmonic compatibility standards demanded by SEC for large industrial consumers and by NEOM's smart grid specifications for sustainable city infrastructure. Unlike passive LC harmonic filters that are tuned to specific harmonic orders and can cause resonance, the WEG AHF uses a real-time digital signal processor to continuously measure the harmonic current spectrum of the connected load and inject equal and opposite compensation currents that cancel harmonics across the 2nd through 50th order simultaneously.
The AHF's control system samples the load current at 40 kHz, processes the harmonic spectrum via a real-time FFT algorithm, and commands the IGBT-based compensation inverter to inject correction current within 250 μs — fast enough to track dynamically changing harmonic loads such as rolling mills, electric arc furnace heating cycles, and elevator drive groups. Beyond harmonic cancellation, the AHF simultaneously provides reactive power compensation (power factor correction) and load current balancing across the three phases — three functions from a single hardware platform, which in previous-generation installations required separate passive filters, capacitor banks, and load balancing reactors. The AHF operates at 380–480 V three-phase, 50/60 Hz, and is available in IP20 wall-mount and IP54 freestanding cabinet formats for installation flexibility across Saudi Arabia's electrical equipment rooms and outdoor utility buildings.
Saudi Arabia's industrial electricity infrastructure is under increasing harmonic stress as the proportion of non-linear loads — variable frequency drives in water pumping and HVAC, UPS systems in data centres, and LED lighting systems — grows in proportion to total consumption. SEC's technical specification GSTD-29-SDMS-032 limits THD at the point of common coupling to 5% for industrial consumers, and SEC enforcement of harmonic limits through power quality surveys and penalty provisions is increasing in parallel with the Kingdom's smart metering rollout. Data centres in Riyadh's King Abdullah Financial District, hospital electrical systems, ARAMCO offshore platform topsides with high VFD density, and NEOM's Cognitive City require active harmonic filtering to meet their building management system power quality specifications and SEC compliance obligations.
Razz Middle East provides complete AHF solutions for Saudi Arabia: power quality surveys using calibrated harmonic analysers, filter sizing per IEEE 519 methodology, AHF supply, installation, and commissioning, and post-installation power quality verification reports. Our team issues stamped power quality compliance reports for SEC regulatory submissions. The AHF is supplied with Modbus TCP/IP communication for integration into building management systems and industrial SCADA platforms. Contact Razz Middle East for a power quality survey and AHF sizing proposal with SAR investment and payback analysis.
Technical Specifications
Full specifications for the AHF-100A
- Rated Current
- 30–300 A per unit (parallel to 1200 A)
- Voltage
- 380–480 V, 50/60 Hz, three-phase
- Harmonic Orders Compensated
- 2nd through 50th
- THDI Reduction
- To <5% (IEEE 519-2014)
- Response Time
- <250 μs
- Sampling Rate
- 40 kHz
- Enclosure
- IP20 (wall-mount) / IP54 (cabinet)
- Additional Functions
- Reactive power compensation, load balancing
Key Features & Benefits
- Real-time 40 kHz sampling and 250 μs response tracks dynamically changing harmonic loads — rolling mills, arc furnaces, elevator groups — faster than passive filter resonance can develop.
- Simultaneous harmonic cancellation, reactive power compensation, and load current balancing from a single hardware platform replaces three separate passive system components with one active device.
- Compensation across harmonic orders 2 through 50 in a single pass eliminates all significant harmonic components, unlike passive tuned filters that address only specific selected orders and may amplify others.
- Modbus TCP/IP communication interface transmits harmonic spectrum, THD, power factor, and current balance data to SCADA and building management systems for continuous power quality monitoring.
- Modular parallel architecture scales from 30 A to 1,200 A by connecting multiple units without derating individual units, enabling cost-effective incremental capacity addition as facility loads grow.
- IEEE 519-2014 and IEC 61000-3-2/4 compliance with documented measurement methodology satisfies SEC harmonic penalty provisions and NEOM smart grid power quality specifications.
Industrial Applications in Saudi Arabia
- Data centre power distribution systems in Riyadh, Jeddah, and NEOM where high-density UPS and server loads generate significant harmonic content requiring active filtering for SEC compliance.
- Hospital and healthcare facility main distribution boards where harmonic distortion from MRI, CT scanner, and LED lighting loads must be controlled to protect sensitive medical instrument power supplies.
- Industrial facilities with high VFD density — NWC pump stations, SABIC compressor buildings, and ARAMCO process plants — where aggregate harmonic currents from multiple drives exceed IEEE 519 limits.
- Shopping centres and commercial complexes with large LED lighting and HVAC VFD populations where SEC power quality survey enforcement requires demonstrated THD compliance.
- NEOM Cognitive City smart building electrical distribution where active harmonic filtering integrates with the building energy management system for continuous power quality optimisation.
- Electric vehicle charging station clusters in commercial and government facilities where multiple non-linear EV chargers operating simultaneously create harmonic pollution on the building's distribution system.
Industrial Supplier in Saudi Arabia
Get a Quote for the WEG AHF Active Harmonic Filter
We respond within 4 business hours. Send model AHF-100A for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.
Frequently Asked Questions — AHF-100A
Common questions from buyers in Saudi Arabia and the GCC