Product image coming soon
AcuAMP
AcuAMP ACTR750-42L-F AcuAMP Split-Core Current Transformers
Model: ACTR750-42L-F
Ships from our supplier in Italy — this is why import, clearance and duty are added at checkout. We handle the import, customs clearance and delivery to your door.
Goods price only — import, clearance and duty are calculated at checkout. Minimum order SAR 500 per country of shipment.
Shipping, customs clearance, duty and VAT are calculated at checkout from your full order — the cost per item falls as you add more.
Payment by bank transfer · Order confirmed within 4 business hours
You May Also Need
4-hour response · Pricing in SAR · Delivery across all KSA regions
AcuAMP ACTR750-42L-F AcuAMP Split-Core Current Transformers
Razz supplies AcuAMP split-core current transformers to Saudi buyers, sourced to order rather than held as order-based supply. AcuAMP is Accuenergy's current-transformer brand, producing split-core and solid-core CTs used to measure current for energy metering and monitoring without breaking the primary conductor.
AcuAMP ACTR750-42L-F
This page covers AcuAMP part number ACTR750-42L-F — AcuAMP Split-Core Current Transformers. Quote the full part number with your enquiry and the item is unambiguous: one part number identifies one exact product variant, including options that are not visible in the description.
About AcuAMP Split-Core Current Transformers
Split-core current transformers clamp around an existing conductor without disconnecting it, inducing a proportional secondary current or voltage signal that a meter or monitoring device reads to determine load current, which makes them practical for retrofitting metering onto live panels. Part numbers such as ACTR750-42L-F and ACT200-42L-F encode the primary current rating window, core aperture size (which must be large enough to clamp around the target conductor or busbar) and output signal type (current or voltage output). Because CT accuracy depends on correct primary current range and proper core closure around the conductor, an oversized aperture on an undersized conductor, or a CT rated well above the actual load current, both reduce measurement accuracy. Aperture size in particular is a physical constraint that must be checked against the conductor or busbar dimensions before ordering, not just the current rating.
AcuAMP Split-Core Current Transformers in Saudi Arabia
AcuAMP current transformers are used in Saudi energy-metering and sub-metering installations, including facility energy-monitoring projects, panel retrofits adding metering to existing distribution boards, and building-management systems tracking electrical consumption across commercial and industrial sites. They are typically specified by an electrical or energy-management contractor retrofitting metering onto a live panel, matched to the conductor size and the meter or monitoring device they feed. Confirming both the current rating and the physical aperture size against the actual busbar or cable being measured avoids a CT that either does not fit or under-reads the load. This kind of metering retrofit is common in energy-efficiency and sub-metering projects across the Kingdom's commercial and industrial building stock.
Ordering and lead time
Order AcuAMP current transformers by the full part number including current rating window, aperture size and output signal type, and measure the target conductor or busbar dimensions before ordering. Razz sources each unit on request and delivers duty-paid into Saudi Arabia, with a typical lead time of around three weeks from confirmed order. Confirm the connected meter or monitoring device's expected input type (current or voltage output) so the CT and meter are compatible. Where multiple CTs are needed for a three-phase installation, order matched sets to keep accuracy consistent across phases.
Specifications are taken from the supplier's published catalogue data. Confirm against the manufacturer's current datasheet before ordering.
Technical Specifications
Full specifications for the ACTR750-42L-F
- AcuAMP part number
- ACTR750-42L-F
- Product type
- AcuAMP Split-Core Current Transformers
- Origin
- ships from our supplier in Italy
- Typical lead time
- 3 weeks
Industrial Supplier in Saudi Arabia
Get a Quote for the AcuAMP ACTR750-42L-F AcuAMP Split-Core Current Transformers
We respond within 4 business hours. Send model ACTR750-42L-F for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.
Frequently Asked Questions — ACTR750-42L-F
Common questions from buyers in Saudi Arabia and the GCC
What is the AcuAMP ACTR750-42L-F AcuAMP Split-Core Current Transformers (ACTR750-42L-F) and what is it used for?
Razz supplies AcuAMP split-core current transformers to Saudi buyers, sourced to order rather than held as order-based supply. AcuAMP is Accuenergy's current-transformer brand, producing split-core and solid-core CTs used to measure current for energy metering and monitoring without breaking the primary conductor.
Where can I buy the AcuAMP ACTR750-42L-F in Saudi Arabia?
Razz Middle East supplies genuine AcuAMP products including the AcuAMP ACTR750-42L-F AcuAMP Split-Core Current Transformers (ACTR750-42L-F) across all regions of Saudi Arabia — Riyadh, Jeddah, Dammam, Al Khobar, Jubail, Yanbu, Mecca, and Medina. We source fast-moving items to order and can source specialist configurations. Request a quote on this page for same-day pricing.
How do I get the best price for the ACTR750-42L-F in KSA?
Click "Request Free Quote" on this page or message us the model number ACTR750-42L-F on WhatsApp. Our technical sales team responds within 4 business hours with a competitive price in SAR and a confirmed delivery lead time — with no hidden charges or handling fees.
Does Razz Middle East supply genuine AcuAMP products in Saudi Arabia?
Yes. Razz Middle East is an independent industrial supplier, not an appointed AcuAMP distributor. We source through AcuAMP OEM channels or through authorised AcuAMP distributor channels and supply 100% genuine product with full manufacturer warranty and documentation, serving the oil & gas, petrochemical, power generation, water, construction and manufacturing sectors across the Kingdom.
What is the delivery lead time for the AcuAMP ACTR750-42L-F AcuAMP Split-Core Current Transformers in Saudi Arabia?
Items are sourced to order and delivered duty-paid, typically 3 weeks, to Riyadh, Dammam, Jeddah and the Eastern Province. Project orders and non-standard configurations can take longer. Contact us with the exact model number ACTR750-42L-F to confirm the lead time for your quantity.
Can the ACTR750-42L-F be supplied for industrial projects in KSA?
Yes. Razz Middle East is an approved vendor to SABIC, Ma'aden, Sadara, Saudi Energy, ACWA Power, Safari Group and others. For project orders we provide the manufacturer's technical documentation and certificates of conformity for your vendor approval file. Contact our project team with your project specification.