Kilsen
KL710A

Product image coming soon

Kilsen

Kilsen KL710A Kilsen Motor Protection & Timing Relays

Model: KL710A

Kilsen part number: KL710AProduct type: Kilsen Motor Protection & Timing RelaysOrigin: ships from our supplier in ItalyTypical lead time: 3 weeksApprox. Weight: 0.5 kgHS Code: 8538.90
Sourced to order — delivered duty-paid, typically 3 weeks
Priceexcl. 15% VAT

Exported from Italy — ships from our supplier's warehouse there; we handle the import, customs clearance and delivery to your door.

336.60/ unit

Product price only. Shipping, customs clearance, duty and VAT are calculated at checkout on your whole order. Minimum order SAR 500 per country of shipment.

Qty
1
Goods (1 × 336.60) 336.60

Payment by bank transfer · Order confirmed within 4 business hours

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

Kilsen KL710A Kilsen Motor Protection & Timing Relays

Kilsen makes thermal overload relays, timing relays and motor-protection devices used inside motor control centres and control panels. Razz Middle East sources Kilsen relays such as the KL710A into Saudi Arabia to order, matched to the contactor and motor current rating already installed rather than a generic protection relay.

Kilsen KL710A

This page covers Kilsen part number KL710A — Kilsen Motor Protection & Timing Relays. Quote the full part number with your enquiry and the item is unambiguous: one part number identifies one exact product variant, including options that are not visible in the description.

About Kilsen Motor Protection & Timing Relays

A thermal overload or timing relay such as the KL710A mounts directly onto a matching contactor and trips the motor circuit when current exceeds a set adjustable range for a sustained period, protecting the motor winding from overheating on jam, single-phasing or mechanical overload. The adjustable current range, trip class (how fast it trips relative to overload level) and mounting footprint must match the contactor frame size — a relay rated for the wrong current range either fails to protect the motor or nuisance-trips under normal starting current. Kilsen's range spans small direct-mount relays for compact contactors up to larger adjustable-range units for higher-current motor starters, alongside separate timing relays for on-delay, off-delay or star-delta switching sequences.

Kilsen Motor Protection & Timing Relays in Saudi Arabia

Motor protection and timing relays of this class are standard components inside motor control centres across Saudi cement, water treatment, food processing and general manufacturing plants, wherever a three-phase motor is started through a contactor rather than a variable-frequency drive. Because these relays are sized to the exact motor full-load current, panel builders and maintenance teams keep the current range and contactor frame recorded against each starter position, and replacement is normally like-for-like to preserve the protection setting. Dusty and high-ambient-temperature conditions in outdoor MCC rooms make correct trip-class selection important to avoid nuisance tripping during hot-weather motor starts.

Ordering and lead time

Quote the full relay model, for example KL710A, together with the adjustable current range setting and the contactor model it mounts to — confirm the motor's full-load current so the correct range is selected, since relays in this family cover several overlapping but distinct current bands. Razz sources these relays to order with delivery duty-paid into Saudi Arabia; standard lead time is 3 weeks from confirmed order. No local stock is held.

Specifications are taken from the supplier's published catalogue data. Confirm against the manufacturer's current datasheet before ordering.

Technical Specifications

Full specifications for the KL710A

Kilsen part number
KL710A
Product type
Kilsen Motor Protection & Timing Relays
Origin
ships from our supplier in Italy
Typical lead time
3 weeks

Industrial Supplier in Saudi Arabia

Get a Quote for the Kilsen KL710A Kilsen Motor Protection & Timing Relays

We respond within 4 business hours. Send model KL710A for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

Frequently Asked Questions — KL710A

Common questions from buyers in Saudi Arabia and the GCC

What is the Kilsen KL710A Kilsen Motor Protection & Timing Relays (KL710A) and what is it used for?

Kilsen makes thermal overload relays, timing relays and motor-protection devices used inside motor control centres and control panels. Razz Middle East sources Kilsen relays such as the KL710A into Saudi Arabia to order, matched to the contactor and motor current rating already installed rather than a generic protection relay.

Where can I buy the Kilsen KL710A in Saudi Arabia?

Razz Middle East supplies genuine Kilsen products including the Kilsen KL710A Kilsen Motor Protection & Timing Relays (KL710A) across all regions of Saudi Arabia — Riyadh, Jeddah, Dammam, Al Khobar, Jubail, Yanbu, Mecca, and Medina. We source fast-moving items to order and can source specialist configurations. Request a quote on this page for same-day pricing.

How do I get the best price for the KL710A in KSA?

Click "Request Free Quote" on this page or message us the model number KL710A on WhatsApp. Our technical sales team responds within 4 business hours with a competitive price in SAR and a confirmed delivery lead time — with no hidden charges or handling fees.

Does Razz Middle East supply genuine Kilsen products in Saudi Arabia?

Yes. Razz Middle East is an independent industrial supplier, not an appointed Kilsen distributor. We source through Kilsen OEM channels or through authorised Kilsen distributor channels and supply 100% genuine product with full manufacturer warranty and documentation, serving the oil & gas, petrochemical, power generation, water, construction and manufacturing sectors across the Kingdom.

What is the delivery lead time for the Kilsen KL710A Kilsen Motor Protection & Timing Relays in Saudi Arabia?

Items are sourced to order and delivered duty-paid, typically 3 weeks, to Riyadh, Dammam, Jeddah and the Eastern Province. Project orders and non-standard configurations can take longer. Contact us with the exact model number KL710A to confirm the lead time for your quantity.

Can the KL710A be supplied for industrial projects in KSA?

Yes. Razz Middle East is an approved vendor to SABIC, Ma'aden, Sadara, Saudi Energy, ACWA Power, Safari Group and others. For project orders we provide the manufacturer's technical documentation and certificates of conformity for your vendor approval file. Contact our project team with your project specification.