ERICO ERITECH 5/8" Copper-Bonded Ground Rod 1800mm
Model: GR5858
4-hour response · Pricing in SAR · Delivery across all KSA regions
GR5858 — ERICO ERITECH 5/8" Copper-Bonded Ground Rod 1800mm
The nVent ERICO ERITECH GR5858 is a 5/8-inch (15.87 mm) diameter copper-bonded steel ground rod measuring 1800 mm in length, providing the foundational earth electrode for electrical safety grounding and lightning protection systems across industrial, commercial, and utility installations. The copper-bonded construction consists of a high-tensile steel core electrolytically plated with minimum 254 microns of 99.9% pure copper — a metallurgical bond that provides the mechanical strength of steel for driven installation into hard Saudi Arabian desert soils while delivering the corrosion resistance and low electrical resistivity of copper at the soil interface. The 254-micron copper layer is specifically engineered to last the full 50-year design life of most industrial facilities without significant corrosion in the range of soil resistivities encountered in Saudi Arabia — from the sandy sandy soils of the Rub' Al Khali desert to the saline-contaminated coastal soils of the Eastern Province Arabian Gulf coast.
Electrical grounding is a foundational safety system for every electrical installation in Saudi Arabia. The National Electrical Code (NFPA 70) as adopted and amended by SASO, the Saudi Electricity Company Grid Code, and IEC 62305 lightning protection standard all mandate low-impedance earth electrode systems with ground rod arrays as the primary electrode type for new industrial and commercial construction. At Saudi Aramco's upstream facilities in the Eastern Province — where summer thunderstorm activity generates ground flash densities of up to 2 flashes per km² per year in some sub-regions — the ERITECH GR5858 ground rod is specified in lightning protection earth electrode systems to carry the 200 kA peak lightning current (10/350 μs) specified in IEC 62305-3 Class I systems without thermal damage or electrode interface deterioration. The rod's high-tensile steel core withstands the physical driving stresses of installation in the compacted gravel and calcite-cemented (sabkha) soils common in ARAMCO's Eastern Province field locations.
SABIC's Jubail Industrial City facilities present a particularly demanding grounding environment due to the combination of industrial soil contamination, salt-air corrosion, and the high ground fault currents generated by the extensive medium-voltage distribution networks feeding major chemical plants. ERITECH GR5858 rods are the standard earth electrode specification for SABIC substation earth grids, equipment grounding electrode systems, and lightning protection earth terminations throughout Jubail I and Jubail II. The 254-micron copper bond provides measurably lower electrode-to-soil contact resistance than bare steel rods in all Saudi soil types, and the resistance to sulphate and chloride soil attack is demonstrated through ERITECH's extensive corrosion testing data — documentation that supports SABIC's 25-year corrosion warranty requirement for buried metalwork.
Razz Middle East holds ERITECH GR5858 rods in single and bulk pallet quantities with immediate availability for Riyadh, Dammam, Jubail, and Yanbu delivery. We supply the complete nVent ERICO grounding system: driving heads, coupling sleeves for extended depth drives, exothermic welding (CADWELD) connection materials, ground rod clamps, and resistance measurement equipment. Our grounding engineers provide complete IEC 62305 and NFPA 780 lightning protection system designs, ground resistance calculations, soil resistivity surveys, and commissioning test reports, including ARAMCO GI-0002.102 lightning protection submittals.
Technical Specifications
Full specifications for the GR5858
- Diameter
- 5/8 inch (15.87 mm)
- Length
- 1800 mm
- Core Material
- High-tensile steel
- Copper Bond Thickness
- 254 microns minimum (electrolytic)
- Copper Purity
- 99.9%
- Peak Current Capacity
- 200 kA (10/350 μs per IEC 62305)
- Tensile Strength
- 550 MPa minimum
- Approvals
- UL 467, CSA, IEC 62561
Key Features & Benefits
- 254-micron electrolytic copper bond provides the corrosion resistance and low electrode-to-soil contact resistance of copper with the mechanical strength of high-tensile steel — enabling driven installation into hard Saudi Arabian desert and sabkha soils.
- 200 kA peak lightning current capacity (10/350 μs per IEC 62305) withstands the Class I lightning protection system discharge requirement without thermal damage or copper bond delamination.
- Corrosion resistance validated in chloride-contaminated coastal soils and sulphate-rich desert soils — both conditions prevalent in Saudi Arabia's Eastern Province ARAMCO and Jubail SABIC installation environments.
- Pointed lower tip and flat upper end with standard 5/8-inch thread pitch accept standard driving heads and coupling sleeves for single-pass or extended-depth driving in compacted gravel and calcite-cemented soils.
- UL 467 listed and IEC 62561 certified, providing the testing documentation required for ARAMCO GI-0002.102 lightning protection system material submittals and SABIC grounding system material qualifications.
- Compatible with nVent ERICO CADWELD exothermic welding for permanent, molecular-bond connections to grounding conductors — the low-resistance connection method required by IEC 62561-2 for lightning current-carrying joints.
Industrial Applications in Saudi Arabia
- Lightning protection earth electrode systems at Saudi Aramco upstream facilities in the Eastern Province, including well pads, gas-oil separation plants, and pipeline pump stations in high ground-flash-density zones.
- Substation earth grid electrode systems for SABIC's medium-voltage distribution substations throughout Jubail Industrial City, where high ground fault current levels and corrosive industrial soils require copper-bonded rod arrays.
- Equipment grounding electrode systems at Eastern Province oil field facilities — compressor stations, metering stations, and field instrument shelters — where low-impedance grounding protects personnel and instrumentation from fault voltage.
- Lightning protection earth termination at NEOM coastal facility structures on the Aqaba Gulf coast, where combination of lightning exposure and marine corrosion environment demands copper-bonded electrode with documented corrosion resistance.
- Tower base grounding for telecom masts, radar installations, and remote field monitoring antenna structures across Saudi Arabia's desert interior, where high soil resistivity requires deep-driven extended-length electrode arrays.
Industrial Supplier in Saudi Arabia
Get a Quote for the ERICO ERITECH 5/8" Copper-Bonded Ground Rod 1800mm
We respond within 4 business hours. Send model GR5858 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.
Frequently Asked Questions — GR5858
Common questions from buyers in Saudi Arabia and the GCC
More nvent Products
ERICO ERITECH BB6G Bonding Bar Grounding Busbar for Hazardous Areas
BB6G
HOFFMAN A-16P16SS Stainless Steel Enclosure 406×406×152mm
A-16P16SS
HOFFMAN A-20P20SS Stainless Steel Enclosure 508×508×152mm
A-20P20SS
Pyrotenax MI 2-Core 1.5mm² Fire-Rated Mineral Insulated Cable
105-2C1.5
Pyrotenax MI 4-Core 2.5mm² Fire-Rated Mineral Insulated Cable
105-4C2.5
RAYCHEM BTV-4-CT Constant Wattage Heat Trace Cable 4W/m
BTV-4-CT