105-2C1.5

Product image coming soon

nvent

Pyrotenax MI 2-Core 1.5mm² Fire-Rated Mineral Insulated Cable

Model: 105-2C1.5

Conductors: 2 × 1.5 mm² annealed copperInsulation: Compacted magnesium oxide (MgO)Outer Sheath: Seamless copper tubeFire Performance: BS 6387 Category CWZ, IEC 60331-21 (950°C/180 min)
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

105-2C1.5 — Pyrotenax MI 2-Core 1.5mm² Fire-Rated Mineral Insulated Cable

The nVent Pyrotenax 105-2C1.5 is a mineral insulated (MI) fire-rated cable comprising two 1.5 mm² copper conductors encased in compacted magnesium oxide (MgO) insulation within a seamless copper tube outer sheath, providing an inherently fire-proof cable that maintains circuit integrity throughout the full duration of a building fire without generating toxic smoke or halogen gases. Mineral insulation is the only cable insulation technology proven to maintain circuit function at temperatures exceeding 1000°C — far beyond the 850°C fire performance required by BS 6387 Category CWZ (the most demanding fire resistance classification) and the 950°C/180-minute fire resistance required by IEC 60331-21. Unlike thermoplastic and thermoset cables that rely on flame-retardant compounds to slow fire progression, the Pyrotenax cable has no organic insulation material to burn: its MgO insulation is a refractory mineral that is chemically inert at all practical fire temperatures, making it the only cable technology that is physically incapable of contributing to fire load or smoke density in a fire scenario.

Saudi Aramco's fire safety infrastructure requirements — codified in GI-0002.100 (General Instruction for Fire Protection) and the SAES-E series of electrical specifications — mandate mineral insulated or equivalent fire-rated cables for all life safety system circuits: fire detection and alarm, fire suppression system control, emergency lighting, fire door release, PA/VA system, and emergency power supply to critical loads in process plants and administrative buildings throughout the Kingdom. The Pyrotenax 105-2C1.5 specifically addresses the two-core 1.5 mm² requirement that covers the majority of ARAMCO fire detection panel field wiring: detector loops, call point circuits, and zone input modules are universally wired in 2C 1.5 mm², and the Pyrotenax MI specification exceeds all performance levels required by ARAMCO GI-0002.100 with a documented margin that satisfies even the most demanding ARAMCO project engineer review.

At SABIC's Jubail complex, Pyrotenax MI cable is the specified cable for fire detection panel wiring in all Areas 1 and 2 classified facilities — those containing explosive or flammable materials — where circuit failure during a fire incident would disable the very systems needed to control the emergency. The Ministry of Interior (Directorate of Civil Defence) requires BS 6387 CWZ certified fire circuit cables for high-rise buildings and places of assembly throughout the Kingdom, a requirement that applies to the growing portfolio of Vision 2030 landmark developments: the Qiddiya sports and entertainment city, the Diriyah cultural heritage complex, KAEC City Centre, and Amaala luxury coastal resort. For these flagship projects, Pyrotenax MI cable is specified not only for compliance but for the confidence it provides to project owners, operators, and civil defence authority approvers that life safety circuits will function under the worst-case fire conditions.

Razz Middle East holds Pyrotenax MI 105-2C1.5 in standard 25 m, 50 m, and 100 m coil lengths for immediate despatch, alongside the full range of Pyrotenax termination kits, pot-seal assemblies, test links, and stainless steel clips. Our life safety engineering team provides fire cable selection guidance aligned with Saudi Civil Defence (NFPA 72 and BS 5839-1 based) requirements, ARAMCO GI-0002.100 submittals, and SABIC fire detection panel wiring specifications, ensuring that Pyrotenax MI systems are correctly designed, terminated, and documented for authority approval in KSA.

Technical Specifications

Full specifications for the 105-2C1.5

Conductors
2 × 1.5 mm² annealed copper
Insulation
Compacted magnesium oxide (MgO)
Outer Sheath
Seamless copper tube
Fire Performance
BS 6387 Category CWZ, IEC 60331-21 (950°C/180 min)
Maximum Operating Temperature
250°C (continuous)
Voltage Rating
300/500 V
Smoke/Toxicity
Zero organic material — no smoke or toxic gas
Approvals
BS 6387 CWZ, IEC 60331, LPCB

Key Features & Benefits

  • Magnesium oxide mineral insulation is physically incapable of combustion — unlike any polymer-based cable, it contributes zero fire load and produces zero smoke or toxic gas in a fire scenario, protecting occupant escape routes.
  • BS 6387 Category CWZ certification proves circuit integrity survival at 950°C fire temperature, 15 minutes of water spray, and mechanical impact simultaneously — the most demanding fire performance test available.
  • Seamless copper outer tube provides a completely hermetic, moisture-proof cable body that withstands the hostile environment of the fire zone without insulation degradation over the full building design life.
  • 250°C continuous operating temperature allows Pyrotenax MI cable to double as high-temperature power and control wiring in industrial furnace, kiln, and process heating environments beyond its fire safety role.
  • IEC 60331-21 compliance and zero organic material composition satisfy Saudi Aramco GI-0002.100 requirements for fire detection and alarm circuit wiring at process plants and administrative buildings throughout the Kingdom.
  • Compact overall diameter (approximately 7 mm for 105-2C1.5) allows installation in standard fire cable trunking and conduit systems alongside conventional low-smoke zero-halogen cables where mixed fire cable routes are required.

Industrial Applications in Saudi Arabia

  • Fire detection and alarm loop wiring at Saudi Aramco process plants, compressor stations, and administrative buildings across the Eastern Province, in compliance with ARAMCO GI-0002.100 and SAES-E electrical specifications.
  • Fire suppression system (deluge, CO2, FM-200) solenoid valve control circuit wiring at SABIC petrochemical plants in Jubail, where classified hazardous areas demand fire-rated cables with maximum operating temperature ratings.
  • Emergency lighting circuit supply cables in high-rise towers, luxury hotels, and public assembly venues in Vision 2030 developments including Diriyah, Qiddiya, KAEC, and Amaala luxury resort — per Saudi Civil Defence BS 6387 requirements.
  • PA/VA system backbone wiring and fire door release circuit cables in NEOM's The Line residential modules and utility corridors, where fire circuit performance under extreme temperature is a fundamental design requirement.
  • Hospital and healthcare facility life safety circuit wiring at Vision 2030 new city healthcare infrastructure — theatres, ICUs, and emergency departments — where Saudi Building Code and civil defence authority require certified fire-rated cables.