Product image coming soon
nvent
Pyrotenax MI 4-Core 2.5mm² Fire-Rated Mineral Insulated Cable
Model: 105-4C2.5
4-hour response · Pricing in SAR · Delivery across all KSA regions
105-4C2.5 — Pyrotenax MI 4-Core 2.5mm² Fire-Rated Mineral Insulated Cable
The nVent Pyrotenax 105-4C2.5 is a mineral insulated fire-rated cable with four 2.5 mm² copper conductors individually insulated in compacted magnesium oxide within a seamless copper sheath, providing fire circuit integrity to BS 6387 Category CWZ and IEC 60331-21 standards for power and control circuits in the most critical life safety applications. The four-conductor configuration and increased 2.5 mm² conductor cross-section serve the broader range of emergency power supply applications compared to the two-core fire detection variant: the 105-4C2.5 is the standard specification for three-phase emergency lighting supply final circuits (using three line conductors plus neutral in a 3P+N arrangement), single-phase emergency power to critical loads with protective earth, fire suppression system pump motor supply cables, and firefighters' lift motor circuits — all applications requiring the higher current-carrying capacity of 2.5 mm² conductors and the circuit configuration flexibility of four cores.
Saudi Aramco's GI-0002.100 fire protection general instruction and the associated SAES-E electrical standards specify mineral insulated or fire-rated cable for emergency power supply circuits at all process plant facilities, requiring cables that maintain electrical function throughout the full design fire duration to ensure that suppression systems, emergency lighting, PA/VA, and safe shutdown instrumentation remain powered until process isolation is complete. The 105-4C2.5 addresses the supply cable requirements for these loads: at ARAMCO's Abqaiq Plants and Ras Tanura Refinery, emergency lighting panels, fire pump motor control centres, and the emergency diesel generator output feeders to critical loads are all wired in Pyrotenax MI 105-4C2.5 specification to satisfy this requirement. The cable's 250°C continuous operating temperature also makes it suitable for cable routes that pass through the hot zones of a process plant fire — furnace rooms, heater houses, and fired equipment areas — where conventional cables would fail within minutes.
For high-rise developments under Saudi Arabia's National Building Code and Civil Defence requirements — which are closely aligned with BS 5839-6 for automatic fire alarm systems and BS 5266 for emergency lighting — the 105-4C2.5 is specified for emergency lighting final circuit distribution from the central maintained emergency lighting panel to remote emergency luminaire groups. In commercial towers exceeding 23 m height (the Saudi Civil Defence threshold for additional fire safety requirements), emergency lighting cables must maintain circuit integrity for at least 60 minutes at 830°C to satisfy the relevant clauses of the Saudi Building Code's fire safety chapter. The Pyrotenax 105-4C2.5's BS 6387 CWZ rating dramatically exceeds this requirement with survival at 950°C — providing civil defence authorities with the confidence needed for occupancy permit approval.
Razz Middle East supplies Pyrotenax 105-4C2.5 in drum lengths from 25 m to 500 m with full termination hardware: copper pot seals, threaded entry glands, test links, brass and stainless steel clip assemblies, and both indoor and outdoor termination kits with heat-shrink moisture barriers. Our life safety system engineers provide fire cable system design aligned with Saudi Civil Defence, ARAMCO GI-0002.100, and SABIC fire detection specifications, including route design, current rating calculations, BS 6387 compliance submissions, and authority approval documentation packages for major project submissions.
Technical Specifications
Full specifications for the 105-4C2.5
- Conductors
- 4 × 2.5 mm² annealed copper
- Insulation
- Compacted magnesium oxide (MgO)
- Outer Sheath
- Seamless copper tube
- Fire Performance
- BS 6387 Category CWZ, IEC 60331-21 (950°C/180 min)
- Maximum Operating Temperature
- 250°C (continuous)
- Voltage Rating
- 300/500 V
- Current Rating (clipped)
- 28 A (at 70°C ambient)
- Approvals
- BS 6387 CWZ, IEC 60331, LPCB
Key Features & Benefits
- Four 2.5 mm² conductors provide the current capacity and circuit configuration flexibility required for three-phase emergency lighting supply, fire pump motor circuits, and emergency power supply to critical process loads.
- BS 6387 Category CWZ certification — proving 950°C fire survival, water spray resistance, and mechanical impact resistance simultaneously — dramatically exceeds Saudi Civil Defence 60-minute at 830°C requirement for high-rise fire cable.
- Zero organic insulation material means zero contribution to fire load, zero toxic smoke generation, and zero halogen gas — protecting occupant escape routes and firefighters in the fire scenario.
- 250°C continuous operating temperature permits cable routing through furnace rooms, heater houses, and high-temperature process areas at ARAMCO and SABIC plants where conventional fire cable would fail immediately.
- Seamless copper outer tube provides a completely hermetic cable body that resists moisture ingress throughout a 50+ year building design life, eliminating the insulation resistance degradation that affects polymer-insulated cables in humid environments.
- Compatible with Saudi Aramco GI-0002.100 emergency power circuit requirements and Saudi Building Code fire safety chapter mandates for cables in high-rise developments exceeding 23 m height.
Industrial Applications in Saudi Arabia
- Emergency lighting final circuit distribution cables in Saudi high-rise commercial towers, hotels, and mixed-use developments in Riyadh's KAFD, Jeddah's waterfront, and Vision 2030 landmark projects, complying with Saudi Civil Defence BS 6387 requirements.
- Fire pump motor supply and control cables at ARAMCO and SABIC process plant fire suppression systems, where BS 6387 CWZ certification satisfies ARAMCO GI-0002.100 life safety cable specification requirements.
- Emergency power supply feeder cables from emergency diesel generators to critical load distribution boards at ARAMCO process plants, ensuring power continuity for instrumentation shutdown systems throughout design fire duration.
- Firefighters' lift motor circuit cables in high-rise towers and complex developments across Vision 2030 projects, where Saudi Building Code mandates fire-rated circuit integrity for firefighting access lifts throughout the fire.
- Stairwell pressurisation fan motor circuit supply in hospitals, airports, and public assembly buildings at new Saudi cities including NEOM and Qiddiya, where smoke control must remain operational throughout a fire incident.
Industrial Supplier in Saudi Arabia
Get a Quote for the Pyrotenax MI 4-Core 2.5mm² Fire-Rated Mineral Insulated Cable
We respond within 4 business hours. Send model 105-4C2.5 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.
Frequently Asked Questions — 105-4C2.5
Common questions from buyers in Saudi Arabia and the GCC
More nvent Products
ERICO ERITECH 5/8" Copper-Bonded Ground Rod 1800mm
GR5858
ERICO ERITECH BB6G Bonding Bar Grounding Busbar for Hazardous Areas
BB6G
HOFFMAN A-16P16SS Stainless Steel Enclosure 406×406×152mm
A-16P16SS
HOFFMAN A-20P20SS Stainless Steel Enclosure 508×508×152mm
A-20P20SS
Pyrotenax MI 2-Core 1.5mm² Fire-Rated Mineral Insulated Cable
105-2C1.5
RAYCHEM BTV-4-CT Constant Wattage Heat Trace Cable 4W/m
BTV-4-CT