Schneider Electric LADN11 TeSys Contactor Auxiliary Blocks and Coil Modules — LADN11

Image for illustration purposes only. Actual product may vary in appearance.

Schneider Electric

Schneider Electric LADN11 TeSys Contactor Auxiliary Blocks and Coil Modules

Model: LADN11

Schneider Electric part number: LADN11Product type: TeSys Contactor Auxiliary Blocks and Coil ModulesOrigin: ships from our supplier in ItalyTypical lead time: 3 weeksApprox. Weight: 0.15 kgHS Code: 8538.90
Sourced to order — delivered duty-paid, typically 3 weeks
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

Schneider Electric LADN11 TeSys Contactor Auxiliary Blocks and Coil Modules

Razz Middle East supplies Schneider Electric TeSys contactor accessories across Saudi Arabia — auxiliary contact blocks, timing modules, surge suppressors and coil interface modules that clip onto the LC1 contactor range. Every item is sourced to order against the reference you quote and delivered duty-paid to your site. Typical lead time is three weeks from order confirmation.

Schneider Electric LADN11

This page covers Schneider Electric part number LADN11 — TeSys Contactor Auxiliary Blocks and Coil Modules. Quote the full part number with your enquiry and the item is unambiguous: one part number identifies one exact product variant, including options that are not visible in the description.

About TeSys Contactor Auxiliary Blocks and Coil Modules

These are the parts that clip onto a contactor rather than replace it, and the prefix tells you where they mount. LAD references are the front and side accessories for the TeSys D frame: instantaneous auxiliary contact blocks, on-delay and off-delay timing blocks, and mechanical latch and interlock kits. LA1 references are auxiliary blocks for the smaller K and E frames. LA4 references are coil-side modules — RC and varistor surge suppressors, and the interface modules that let a low-power controller output drive a contactor coil directly.

Two things decide whether an accessory is correct. The first is the frame: a block made for TeSys D does not fit TeSys K, and the two ranges are close enough in appearance that this is a genuine ordering trap. The second is the contact configuration, given as the number of normally-open and normally-closed contacts — an 11 block is one of each, a 20 block is two normally-open. Surge suppressors additionally have to match the coil voltage and type, because an RC network sized for an alternating-current coil is not what a direct-current coil needs.

TeSys Contactor Auxiliary Blocks and Coil Modules in Saudi Arabia

Auxiliary blocks are consumed steadily in Saudi motor control centres because they carry the control and interlock wiring rather than the motor current, and control circuits get rewired far more often than power circuits. A pump station that adds a duty-standby changeover, a conveyor that gains a run-status signal to a SCADA system, a starter modified during a plant upgrade — each of those needs contacts a contactor did not originally carry.

Surge suppressors deserve more attention than they usually get. A contactor coil switched by a controller output generates a voltage spike on de-energising, and over months that spike degrades the output transistor or relay in the controller. The failure looks like a controller fault rather than a wiring omission, which is why it is often diagnosed late and expensively. Fitting the suppressor at build time costs very little; retrofitting it after an output card has failed costs a great deal more, and on a plant with frequent start-stop duty the exposure is continuous.

Ordering and lead time

Tell us the contactor the accessory mounts on, not just the accessory reference. The frame is what decides fit, and TeSys D, K, E and F take different blocks despite looking similar on a rail. If you are unsure of the frame, the reference on the front of the contactor gives it to us.

For auxiliary blocks, state the contact configuration you need — how many normally-open and how many normally-closed — and whether the block mounts on the front or the side, since side mounting is limited by what is already fitted. For surge suppressors and interface modules, state the coil voltage and whether it is alternating or direct current, because the module must match the coil rather than the supply. Typical lead time is three weeks from order confirmation. Items are supplied to order and delivered duty-paid, with import and customs clearance handled by us.

Specifications are taken from the supplier's published catalogue data. Confirm against the manufacturer's current datasheet before ordering.

Technical Specifications

Full specifications for the LADN11

Schneider Electric part number
LADN11
Product type
TeSys Contactor Auxiliary Blocks and Coil Modules
Origin
ships from our supplier in Italy
Typical lead time
3 weeks

Industrial Supplier in Saudi Arabia

Get a Quote for the Schneider Electric LADN11 TeSys Contactor Auxiliary Blocks and Coil Modules

We respond within 4 business hours. Send model LADN11 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — LADN11

Common questions from buyers in Saudi Arabia and the GCC

What is the Schneider Electric LADN11 TeSys Contactor Auxiliary Blocks and Coil Modules (LADN11) and what is it used for?

Razz Middle East supplies Schneider Electric TeSys contactor accessories across Saudi Arabia — auxiliary contact blocks, timing modules, surge suppressors and coil interface modules that clip onto the LC1 contactor range. Every item is sourced to order against the reference you quote and delivered duty-paid to your site. Typical lead time is three weeks from order confirmation.

Where can I buy the Schneider Electric LADN11 in Saudi Arabia?

Razz Middle East supplies genuine Schneider Electric products including the Schneider Electric LADN11 TeSys Contactor Auxiliary Blocks and Coil Modules (LADN11) across all regions of Saudi Arabia — Riyadh, Jeddah, Dammam, Al Khobar, Jubail, Yanbu, Mecca, and Medina. We source fast-moving items to order and can source specialist configurations. Request a quote on this page for same-day pricing.

How do I get the best price for the LADN11 in KSA?

Click "Request Free Quote" on this page or message us the model number LADN11 on WhatsApp. Our technical sales team responds within 4 business hours with a competitive price in SAR and a confirmed delivery lead time — with no hidden charges or handling fees.

Does Razz Middle East supply genuine Schneider Electric products in Saudi Arabia?

Yes. Razz Middle East is an independent industrial supplier, not an appointed Schneider Electric distributor. We source through Schneider Electric OEM channels or through authorised Schneider Electric distributor channels and supply 100% genuine product with full manufacturer warranty and documentation, serving the oil & gas, petrochemical, power generation, water, construction and manufacturing sectors across the Kingdom.

What is the delivery lead time for the Schneider Electric LADN11 TeSys Contactor Auxiliary Blocks and Coil Modules in Saudi Arabia?

Items are sourced to order and delivered duty-paid, typically 3 weeks, to Riyadh, Dammam, Jeddah and the Eastern Province. Project orders and non-standard configurations can take longer. Contact us with the exact model number LADN11 to confirm the lead time for your quantity.

Can the LADN11 be supplied for industrial projects in KSA?

Yes. Razz Middle East is an approved vendor to SABIC, Ma'aden, Sadara, Saudi Energy, ACWA Power, Safari Group and others. For project orders we provide the manufacturer's technical documentation and certificates of conformity for your vendor approval file. Contact our project team with your project specification.