
Product image coming soon
Telco
Telco LT110LAP38T3 Telco Thermal Overload Relays and Contactor Accessories
Model: LT110LAP38T3
Ships from our supplier in Italy — this is why import, clearance and duty are added at checkout. We handle the import, customs clearance and delivery to your door.
Goods price only — import, clearance and duty are calculated at checkout. Minimum order SAR 500 per country of shipment.
Shipping, customs clearance, duty and VAT are calculated at checkout from your full order — the cost per item falls as you add more.
Payment by bank transfer · Order confirmed within 4 business hours
4-hour response · Pricing in SAR · Delivery across all KSA regions
Telco LT110LAP38T3 Telco Thermal Overload Relays and Contactor Accessories
Razz supplies Telco thermal overload relays and motor-starter accessories into Saudi Arabia on order. The sample part codes point to a thermal overload relay range (LT/LR series) used alongside contactors to protect motors against sustained overcurrent. Parts are sourced to order and delivered duty-paid; no local stock is held.
Telco LT110LAP38T3
This page covers Telco part number LT110LAP38T3 — Telco Thermal Overload Relays and Contactor Accessories. Quote the full part number with your enquiry and the item is unambiguous: one part number identifies one exact product variant, including options that are not visible in the description.
About Telco Thermal Overload Relays and Contactor Accessories
Thermal overload relays sense motor current through bimetallic elements and trip a contact when current stays above a set threshold long enough to indicate overload rather than a normal start transient. They mount directly on a matching contactor or on a separate base, and are selected by adjustable current range so the relay can be set to the motor's actual full-load current within that band. Short codes such as LT, LR and PA in this bucket most likely identify a relay body size or mounting type rather than a complete orderable reference; a full code such as LT110LAP38T3 fixes the current range, mounting and auxiliary contact configuration together. Razz confirms the complete code and current setting range against the motor being protected before quoting, since a relay set above the motor's actual full-load current defeats the protection it is meant to provide.
Telco Thermal Overload Relays and Contactor Accessories in Saudi Arabia
Thermal overload protection of this kind is fitted to virtually every direct-on-line and star-delta motor starter in Saudi industry, from small pump and fan motors in building services to process motors in cement, water treatment and petrochemical plants. Maintenance teams replace overload relays after nuisance tripping investigations or when a motor is re-rated, matching the new setting range to the motor nameplate current. Ambient temperature inside an unventilated panel enclosure also affects a bimetallic relay's trip point, so panels installed in direct sun without adequate cooling sometimes need their overload settings reviewed rather than simply reset to nameplate current.
Ordering and lead time
Quote the full Telco relay code exactly as marked on the unit (e.g. LT110LAP38T3), not the short prefix alone, since the complete code fixes current range, mounting and contact configuration. State the motor's full-load current and the contactor it must mount to, and note the panel's ambient conditions if nuisance tripping has been an issue on the existing relay. Lead time is 3 weeks; items are sourced to order and delivered duty-paid to site.
Specifications are taken from the supplier's published catalogue data. Confirm against the manufacturer's current datasheet before ordering.
Technical Specifications
Full specifications for the LT110LAP38T3
- Telco part number
- LT110LAP38T3
- Product type
- Telco Thermal Overload Relays and Contactor Accessories
- Origin
- ships from our supplier in Italy
- Typical lead time
- 3 weeks
Industrial Supplier in Saudi Arabia
Get a Quote for the Telco LT110LAP38T3 Telco Thermal Overload Relays and Contactor Accessories
We respond within 4 business hours. Send model LT110LAP38T3 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.
Frequently Asked Questions — LT110LAP38T3
Common questions from buyers in Saudi Arabia and the GCC
What is the Telco LT110LAP38T3 Telco Thermal Overload Relays and Contactor Accessories (LT110LAP38T3) and what is it used for?
Razz supplies Telco thermal overload relays and motor-starter accessories into Saudi Arabia on order. The sample part codes point to a thermal overload relay range (LT/LR series) used alongside contactors to protect motors against sustained overcurrent. Parts are sourced to order and delivered duty-paid; no local stock is held.
Where can I buy the Telco LT110LAP38T3 in Saudi Arabia?
Razz Middle East supplies genuine Telco products including the Telco LT110LAP38T3 Telco Thermal Overload Relays and Contactor Accessories (LT110LAP38T3) across all regions of Saudi Arabia — Riyadh, Jeddah, Dammam, Al Khobar, Jubail, Yanbu, Mecca, and Medina. We source fast-moving items to order and can source specialist configurations. Request a quote on this page for same-day pricing.
How do I get the best price for the LT110LAP38T3 in KSA?
Click "Request Free Quote" on this page or message us the model number LT110LAP38T3 on WhatsApp. Our technical sales team responds within 4 business hours with a competitive price in SAR and a confirmed delivery lead time — with no hidden charges or handling fees.
Does Razz Middle East supply genuine Telco products in Saudi Arabia?
Yes. Razz Middle East is an independent industrial supplier, not an appointed Telco distributor. We source through Telco OEM channels or through authorised Telco distributor channels and supply 100% genuine product with full manufacturer warranty and documentation, serving the oil & gas, petrochemical, power generation, water, construction and manufacturing sectors across the Kingdom.
What is the delivery lead time for the Telco LT110LAP38T3 Telco Thermal Overload Relays and Contactor Accessories in Saudi Arabia?
Items are sourced to order and delivered duty-paid, typically 3 weeks, to Riyadh, Dammam, Jeddah and the Eastern Province. Project orders and non-standard configurations can take longer. Contact us with the exact model number LT110LAP38T3 to confirm the lead time for your quantity.
Can the LT110LAP38T3 be supplied for industrial projects in KSA?
Yes. Razz Middle East is an approved vendor to SABIC, Ma'aden, Sadara, Saudi Energy, ACWA Power, Safari Group and others. For project orders we provide the manufacturer's technical documentation and certificates of conformity for your vendor approval file. Contact our project team with your project specification.