Telemecanique LC1D0910Q7 Telemecanique TeSys D Power Contactors — LC1D0910Q7

Image for illustration purposes only. Actual product may vary in appearance.

Telemecanique

Telemecanique LC1D0910Q7 Telemecanique TeSys D Power Contactors

Model: LC1D0910Q7

Telemecanique part number: LC1D0910Q7Product type: Telemecanique TeSys D Power ContactorsOrigin: ships from our supplier in ItalyTypical lead time: 3 weeksApprox. Weight: 0.5 kgHS Code: 8536.49
Sourced to order — delivered duty-paid, typically 3 weeks
Priceexcl. 15% VAT

Ships from our supplier in Italy — this is why import, clearance and duty are added at checkout. We handle the import, customs clearance and delivery to your door.

1,059.30/ unit

Goods price only — import, clearance and duty are calculated at checkout. Minimum order SAR 500 per country of shipment.

Qty
1
Goods (1 × 1,059.30) 1,059.30

Shipping, customs clearance, duty and VAT are calculated at checkout from your full order — the cost per item falls as you add more.

Payment by bank transfer · Order confirmed within 4 business hours

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

Telemecanique LC1D0910Q7 Telemecanique TeSys D Power Contactors

LC1D contactors are the TeSys D range, sold under the Telemecanique name for years and still marked that way on many Saudi panels. Razz Middle East supplies these references to order, matched to the coil voltage suffix you quote. Nothing is held locally; contactors are sourced against the confirmed reference and delivered duty-paid, three weeks from order confirmation.

Telemecanique LC1D0910Q7

This page covers Telemecanique part number LC1D0910Q7 — Telemecanique TeSys D Power Contactors. Quote the full part number with your enquiry and the item is unambiguous: one part number identifies one exact product variant, including options that are not visible in the description.

About Telemecanique TeSys D Power Contactors

TeSys D is an IEC three-pole contactor range for motor switching and general load switching, built as a DIN-rail block with main contacts, a coil and integral auxiliary contacts. The reference is read in parts. LC1 identifies a contactor, D identifies the TeSys D frame, and the digits that follow place the device within the range by rating. The pair of digits after that describes the auxiliary contacts built into the body, written as the number of normally open followed by the number of normally closed. The letter-and-digit group at the end is the coil code, and it decides whether the contactor will work in your panel: it identifies the coil voltage and, for AC coils, the frequency. Suffixes such as F7, M7, Q7, U7, R6 and M6 all appear in the range and are not interchangeable, so the coil code must be quoted rather than inferred. The range builds up with accessories: add-on auxiliary blocks, timer and interlock modules, LRD thermal overload relays, and reversing and star-delta assemblies.

Telemecanique TeSys D Power Contactors in Saudi Arabia

TeSys D is one of the most widely installed contactor ranges in the Kingdom, largely because so much of the motor control centre base was built to IEC practice by European and local panel builders. It runs pump and fan starters in water networks and desalination pumping stations, chiller and air-handling starters in HVAC, conveyor and mixer starters in cement and building materials, and line starters in food and beverage plants around Riyadh, Jeddah and Dammam. The supply context is 380/400 V at 60 Hz from the SEC network, and frequency matters more for the coil than for the main contacts: an AC coil intended for 50 Hz behaves differently on a 60 Hz supply, so coil selection is not a formality. Panels in unconditioned switch rooms and outdoor kiosks also run hot, which is the usual reason a coil fails before the contacts wear out.

Ordering and lead time

Quote the complete reference including the coil suffix, exactly as it reads on the device's front label. Ordering an LC1D of the right size with the wrong coil code is the commonest error on this range, and it cannot be corrected in the field: the coil is not a user-changeable item on most of these frames. Confirm the auxiliary contact arrangement too, because a replacement with a different built-in configuration will not drop into the same control wiring. Tell us whether you also need the matching LRD overload relay, an auxiliary block or a star-delta mounting kit, as those are separate references. Devices marked Telemecanique and devices marked Schneider Electric may carry the same reference, so quote the reference rather than the brand.

Specifications are taken from the supplier's published catalogue data. Confirm against the manufacturer's current datasheet before ordering.

Technical Specifications

Full specifications for the LC1D0910Q7

Telemecanique part number
LC1D0910Q7
Product type
Telemecanique TeSys D Power Contactors
Origin
ships from our supplier in Italy
Typical lead time
3 weeks

Industrial Supplier in Saudi Arabia

Get a Quote for the Telemecanique LC1D0910Q7 Telemecanique TeSys D Power Contactors

We respond within 4 business hours. Send model LC1D0910Q7 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — LC1D0910Q7

Common questions from buyers in Saudi Arabia and the GCC

What is the Telemecanique LC1D0910Q7 Telemecanique TeSys D Power Contactors (LC1D0910Q7) and what is it used for?

LC1D contactors are the TeSys D range, sold under the Telemecanique name for years and still marked that way on many Saudi panels. Razz Middle East supplies these references to order, matched to the coil voltage suffix you quote. Nothing is held locally; contactors are sourced against the confirmed reference and delivered duty-paid, three weeks from order confirmation.

Where can I buy the Telemecanique LC1D0910Q7 in Saudi Arabia?

Razz Middle East supplies genuine Telemecanique products including the Telemecanique LC1D0910Q7 Telemecanique TeSys D Power Contactors (LC1D0910Q7) across all regions of Saudi Arabia — Riyadh, Jeddah, Dammam, Al Khobar, Jubail, Yanbu, Mecca, and Medina. We source fast-moving items to order and can source specialist configurations. Request a quote on this page for same-day pricing.

How do I get the best price for the LC1D0910Q7 in KSA?

Click "Request Free Quote" on this page or message us the model number LC1D0910Q7 on WhatsApp. Our technical sales team responds within 4 business hours with a competitive price in SAR and a confirmed delivery lead time — with no hidden charges or handling fees.

Does Razz Middle East supply genuine Telemecanique products in Saudi Arabia?

Yes. Razz Middle East is an independent industrial supplier, not an appointed Telemecanique distributor. We source through Telemecanique OEM channels or through authorised Telemecanique distributor channels and supply 100% genuine product with full manufacturer warranty and documentation, serving the oil & gas, petrochemical, power generation, water, construction and manufacturing sectors across the Kingdom.

What is the delivery lead time for the Telemecanique LC1D0910Q7 Telemecanique TeSys D Power Contactors in Saudi Arabia?

Items are sourced to order and delivered duty-paid, typically 3 weeks, to Riyadh, Dammam, Jeddah and the Eastern Province. Project orders and non-standard configurations can take longer. Contact us with the exact model number LC1D0910Q7 to confirm the lead time for your quantity.

Can the LC1D0910Q7 be supplied for industrial projects in KSA?

Yes. Razz Middle East is an approved vendor to SABIC, Ma'aden, Sadara, Saudi Energy, ACWA Power, Safari Group and others. For project orders we provide the manufacturer's technical documentation and certificates of conformity for your vendor approval file. Contact our project team with your project specification.