ABB Uras26 NDIR Infrared Gas Analyzer CH4
The ABB Uras26 NDIR Infrared Gas Analyzer CH4 is a ndir infrared analyzer from ABB Measurement & Analytics, engineered for demanding process measurement duty across the oil & gas, petrochemical, power and water sectors of Saudi Arabia. The Uras26 CH4 delivers continuous, drift-stable measurement of CH4 using ndir infrared analyzer technology, suited to emissions monitoring and process gas analysis at Saudi refineries, power stations and petrochemical plants. Headline specifications include Type NDIR infrared analyzer, Component / variant CH4, Measured IR-active gases, Output / protocol 4-20 mA, Modbus, Ethernet, OPC, making it a dependable choice where measurement accuracy, long-term stability and low maintenance directly affect plant uptime and product quality.
In the Kingdom, instrumentation must perform reliably in one of the harshest operating environments on earth. Ambient temperatures regularly exceed 50 °C, airborne dust and sand are constant, and coastal humidity along the Eastern Province accelerates corrosion. The URAS26-CH4 is built with robust 316L stainless steel wetted parts, epoxy-coated or stainless housings rated to IP66/IP67, and wide-temperature electronics that hold their published accuracy through the full Saudi seasonal swing. ATEX, IECEx and SIL-rated variants are available for the hazardous Zone 1 and Zone 2 areas common to Saudi Aramco gas plants and refineries, and SAES-compliant configurations are offered for projects governed by Saudi Aramco engineering standards.
Operators at Saudi Aramco (Ghawar / Abqaiq oil & gas processing), NWC (national water network treatment works) and SEC (Saudi Electricity Company power generation) deploy ABB Measurement instrumentation because of its proven diagnostics, intuitive HMI configuration and seamless integration with Foundation Fieldbus, PROFIBUS PA, HART and 4-20 mA control architectures. Built-in self-monitoring detects sensor drift, process build-up and electronic faults early, allowing maintenance teams at Petro Rabigh and SATORP to move from reactive repair to predictive, condition-based servicing — a key requirement under Saudi Vision 2030 operational-excellence programmes.
Razz Middle East is a specialist industrial distributor supplying genuine ABB Measurement & Analytics products throughout Saudi Arabia. We hold fast-moving instrumentation in regional stock and offer rapid quotation, configuration support and after-sales engineering. Delivery to the Eastern Province — including Jubail, Dammam and Al Khobar — Riyadh, Yanbu and Jeddah is arranged on short lead times, with full manufacturer documentation, calibration certificates and Saudi Aramco material data sheets provided on request. Contact Razz Middle East at sales@razz.sa to configure the URAS26-CH4 for your application, request a datasheet, or obtain a competitive quotation backed by in-Kingdom technical support.
Technical Specifications
Full specifications for the URAS26-CH4
- Type
- NDIR infrared analyzer
- Component / variant
- CH4
- Measured
- IR-active gases
- Output / protocol
- 4-20 mA, Modbus, Ethernet, OPC
- Sample handling
- Heated line / cooler / filter conditioning
- Certification
- ATEX / IECEx Zone 1
- Compliance
- EPA / EN 14181 QAL CEMS
Key Features & Benefits
- 316L stainless wetted parts and IP66/IP67 housing — withstands Saudi desert dust, sand and Eastern Province coastal humidity
- Type: NDIR infrared analyzer with high long-term stability for accurate, low-drift gas analysis measurement
- ATEX, IECEx and SIL-rated variants available for hazardous Zone 1/2 areas at Saudi Aramco gas plants and refineries
- HART, Foundation Fieldbus and PROFIBUS PA communication for seamless integration into existing DCS/PLC control systems
- On-board diagnostics enable predictive maintenance, reducing unplanned downtime at NWC and SEC facilities
Industrial Applications in Saudi Arabia
- Saudi Aramco — Ghawar / Abqaiq oil & gas processing: gas analysis measurement for process control and safety systems
- NWC — national water network treatment works: ndir infrared analyzer duty on critical production lines
- SEC — Saudi Electricity Company power generation: reliable gas analysis monitoring in continuous operation
- Petro Rabigh — Rabigh refining and petrochemicals: instrumentation for plant optimisation and emissions/utility control
- SATORP — Jubail Total refinery: condition-based monitoring under Saudi Vision 2030 reliability programmes
Industrial Supplier in Saudi Arabia
Get a Quote for the ABB Uras26 NDIR Infrared Gas Analyzer CH4
We respond within 4 business hours. Send model URAS26-CH4 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.
Frequently Asked Questions — URAS26-CH4
Common questions from buyers in Saudi Arabia and the GCC
More ABB Measurement & Analytics Products
ABB 2600T-261 – 2600T Remote Seal Transmitter
2600T-261
ABB 2600T-266 – 2600T Series Smart Transmitter
2600T-266
ABB 2601T Low-Pressure Transmitter 0-10 inWC
2601T-0-10INWC
ABB 2601T Low-Pressure Transmitter 0-10 PSI
2601T-0-10PSI
ABB 2601T Low-Pressure Transmitter 0-100 inWC
2601T-0-100INWC
ABB 2601T Low-Pressure Transmitter 0-50 inWC
2601T-0-50INWC