SICK FLM3-CPUN100A06 Safety controller — FLM3-CPUN100A06

Image for illustration purposes only. Actual product may vary in appearance.

SICK

SICK FLM3-CPUN100A06 Safety controller

Model: FLM3-CPUN100A06P/N: 1130366

Connection type: 1 × USB (on the smart plug), 1 × rectangular plug, 48-pin, type: Molex CMC, 1 × rectangular plug, 32-pin, type: Molex CMC, 1 × Ethernet: M12 socket, 4-pin, D-coded, 1 × CAN-I: M12 plug, 5-pin, A-coded, 1 × CAN-O: M12 socket, 5-pin, A-coded, 2 × EFI pro: Socket, M12, 4-pin, D-codedFieldbus, industrial network: Modbus® TCP, SLMP, CANopen, EFI-pro, EtherNet/IP™ CIP Safety™, TCP/IP socketsController networking: Encoder interface: A/B incremental encoder, HTL 24 V
Sourced to order — delivered duty-paid, typically 2–3 weeks
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

SICK FLM3-CPUN100A06 Safety controller

The SICK FLM3-CPUN100A06 Safety controller is a Flexi Mobile series unit from SICK AG, supplied in Saudi Arabia by Razz Middle East under SICK order number 1130366.

This variant, type code FLM3-CPUN100A06, is specified with 1 × usb (on the smart plug) termination.

Safety controllers | Flexi Mobile | FLM3-CPUN100A06 | Application: Safety controller for mobile applications | Safety level: PL e, SIL 3 | Inputs/outputs: 28 safety inputs, 12 safety outputs, 8 test outputs | Number of connectable A/B incremental encoders (non safety): 2 | Encoder interface: A/B incremental encoder, HTL 24 V | Communication interface: Ethernet, Modbus® TCP, SLMP, CAN, CANopen, EFI-pro, EtherNet/IP™ CIP Safety™, TCP/IP-Sockets | Configuration software: Safety Designer | Items supplied: Safety controller, SmartPlug, M5 screw for FE connection, safety instruction, Downloadable operating instructions | Relevant operating instructions: 8026430: Flexi Mobile operating instructions, 8026436: IO XTDO1 operating instructions, 8026442: GCAN1 operating instructions, 8028314: GEPR1 operating instructions

Across Saudi Arabia the Flexi Mobile series is specified for machine guarding, press safety and robot cell protection where Performance Level compliance must be documented for plant HSE audits. Razz Middle East supplies genuine SICK product with full documentation, supporting plants in Jubail, Dammam, Riyadh, Jeddah and Yanbu.

To order the FLM3-CPUN100A06 (SICK part number 1130366), or to confirm the correct variant for your application, request a quotation from Razz Middle East and our team will respond within 4 business hours. We cross-reference legacy SICK part numbers and advise on equivalents where a series has been superseded.

Technical Specifications

Full specifications for the FLM3-CPUN100A06

Connection type
1 × USB (on the smart plug), 1 × rectangular plug, 48-pin, type: Molex CMC, 1 × rectangular plug, 32-pin, type: Molex CMC, 1 × Ethernet: M12 socket, 4-pin, D-coded, 1 × CAN-I: M12 plug, 5-pin, A-coded, 1 × CAN-O: M12 socket, 5-pin, A-coded, 2 × EFI pro: Socket, M12, 4-pin, D-coded
Fieldbus, industrial network
Modbus® TCP, SLMP, CANopen, EFI-pro, EtherNet/IP™ CIP Safety™, TCP/IP sockets
Controller networking
Encoder interface
A/B incremental encoder, HTL 24 V
Safety level
PL e, SIL 3
Drive safety functions
safe stop 0 (SS0), safe stop 1 (SS1), safe stop 2 (SS2), safe operating stop (SOS), safe speed monitoring (SSM), safely-limited speed (SLS), safe direction (SDI), safe brake control (SBC), Safe cam (SCA), Safely-limited position (SLP)
Configuration and diagnostics interface
USB connection via SmartPlug, TCP/IP configuration interface
Configuration method
via software
Application
Safety controller for mobile applications
Enhanced sensor functions
Protective coating
No
Configuration software
Safety Designer
Product segment
Safety controllers
Module
Complete system
Inputs/outputs
28 safety inputs, 12 safety outputs, 8 test outputs
Certificate
EU declaration of conformity, ACMA declaration of conformity, China RoHS, cULus certificate, cTUVus certificate, EC-Type-Examination approval, EC-Type-Examination approval (Machinery Directive), EC-Type-Examination approval (Machinery Regulation), Third party certificate, Information according to Art. 3 of Data Act (Regulation EU 2023/2854)

Key Features & Benefits

  • [
  • ]

Industrial Supplier in Saudi Arabia

Get a Quote for the SICK FLM3-CPUN100A06 Safety controller

We respond within 4 business hours. Send model FLM3-CPUN100A06 for competitive pricing in SAR with delivery across Saudi Arabia and the GCC.

WhatsApp

Frequently Asked Questions — FLM3-CPUN100A06

Common questions from buyers in Saudi Arabia and the GCC

What is the SICK FLM3-CPUN100A06 Safety controller (FLM3-CPUN100A06) and what is it used for?

The SICK FLM3-CPUN100A06 Safety controller is a Flexi Mobile series unit from SICK AG, supplied in Saudi Arabia by Razz Middle East under SICK order number 1130366.

Where can I buy the SICK FLM3-CPUN100A06 in Saudi Arabia?

Razz Middle East supplies genuine SICK products including the SICK FLM3-CPUN100A06 Safety controller (FLM3-CPUN100A06) across all regions of Saudi Arabia — Riyadh, Jeddah, Dammam, Al Khobar, Jubail, Yanbu, Mecca, and Medina. We source fast-moving items to order and can source specialist configurations. Request a quote on this page for same-day pricing.

How do I get the best price for the FLM3-CPUN100A06 in KSA?

Click "Request Free Quote" on this page or message us the model number FLM3-CPUN100A06 on WhatsApp. Our technical sales team responds within 4 business hours with a competitive price in SAR and a confirmed delivery lead time — with no hidden charges or handling fees.

Does Razz Middle East supply genuine SICK products in Saudi Arabia?

Yes. Razz Middle East is an independent industrial supplier, not an appointed SICK distributor. We source through SICK OEM channels or through authorised SICK distributor channels and supply 100% genuine product with full manufacturer warranty and documentation, serving the oil & gas, petrochemical, power generation, water, construction and manufacturing sectors across the Kingdom.

What is the delivery lead time for the SICK FLM3-CPUN100A06 Safety controller in Saudi Arabia?

Items are sourced to order and delivered duty-paid, typically 2-3 weeks, to Riyadh, Dammam, Jeddah and the Eastern Province. Project orders and non-standard configurations can take longer. Contact us with the exact model number FLM3-CPUN100A06 to confirm the lead time for your quantity.

Can the FLM3-CPUN100A06 be supplied for ARAMCO, SABIC, or NEOM projects in KSA?

Yes. Razz Middle East has experience supplying SICK equipment to major industrial projects and EPC contractors across Saudi Arabia. We can provide full technical documentation, Material Inspection Reports (MIR), and certificates of conformity to meet vendor approval requirements. Contact our project team to discuss your specific project requirements.