Panduit PanZone Cat6A 48-Port Patch Panel

Model: CPPL48WBLY

Ports: 48 × Cat6A keystone jack (factory-loaded)Category: TIA-568.2-D Category 6A / ISO 11801 Class EABandwidth: 1–500 MHzSupported Application: 10GbE to 100 m (IEEE 802.3an)
Available — Ships within Saudi Arabia
WhatsApp

4-hour response · Pricing in SAR · Delivery across all KSA regions

Genuine OEM Products
4-Hour RFQ Response
KSA-Wide Delivery
Full Technical Support

CPPL48WBLY — Panduit PanZone Cat6A 48-Port Patch Panel

The Panduit CPPL48WBLY is a 48-port Category 6A UTP patch panel for 19-inch rack or cabinet mounting, forming the structured cabling termination point for ANSI/TIA-568.2-D Cat6A horizontal cabling systems that support 10 Gigabit Ethernet (10GbE) to IEEE 802.3an at distances up to 100 metres. The panel's 48 keystone-jack module positions are factory-loaded with Panduit CJ6X88TGYL Mini-Com Cat6A keystone jacks, each tested and certified to exceed TIA-568.2-D channel performance requirements including insertion loss, NEXT, FEXT, PSNEXT, RL, and ACR-F measurements across the full 1–500 MHz frequency bandwidth. The angled front panel design presents each port at 45 degrees to the horizontal, reducing the bending radius stress on patch cord RJ-45 plugs and enabling higher patch cord density without exceeding Cat6A minimum bend radius requirements.

NEOM's data centre and smart-city telecommunications infrastructure represents the flagship Saudi Arabia application for the Panduit PanZone Cat6A system, of which the CPPL48WBLY patch panel is the horizontal cabling termination component. NEOM's Backbone Exchange — the city's core data centre and internet exchange point — is being designed to Uptime Institute Tier III+ reliability standards, with structured cabling infrastructure specified to TIA-942-A data centre telecommunications infrastructure standard. The TIA-942-A standard mandates Category 6A minimum for horizontal cabling in Tier III data centres, making the CPPL48WBLY the baseline patch panel specification for all active equipment connections in NEOM's network rooms. Panduit's PanZone system has been selected as the preferred structured cabling brand for several NEOM infrastructure packages, with Razz Middle East positioned as the in-Kingdom supply and support partner.

Saudi Arabia's wider data centre construction boom — driven by the Vision 2030 Cloud First policy, CITC's national cloud licensing programme, and the entry of hyperscale cloud providers including AWS, Microsoft Azure, and Google Cloud establishing regional infrastructure in Riyadh — is generating substantial demand for TIA-942 compliant Cat6A patch panels. The CPPL48WBLY satisfies the stringent channel performance requirements specified by hyperscale cloud providers and carrier-neutral data centre operators, and its factory-loaded jack design eliminates field termination inconsistencies that are a common cause of channel test failures on large-scale data centre structured cabling projects. The ARAMCO digitisation programme — including ARAMCO's Data and Analytics centre of excellence in Dhahran and the ARAMCO Trading Company's IT infrastructure in King Abdullah Financial District — also specifies Cat6A structured cabling in its IT infrastructure standards.

Razz Middle East is a Panduit PanZone certified partner and holds CPPL48WBLY and associated Cat6A cable, patch cord, and rack hardware in local stock in Riyadh, positioned for rapid supply to the active data centre construction projects across the Kingdom. Our structured cabling team provides channel performance consulting, TIA-942 zone cabling design, and post-installation Fluke DSX-8000 certification testing to deliver a fully documented, warranty-backed Cat6A infrastructure that satisfies hyperscale tenant requirements.

Technical Specifications

Full specifications for the CPPL48WBLY

Ports
48 × Cat6A keystone jack (factory-loaded)
Category
TIA-568.2-D Category 6A / ISO 11801 Class EA
Bandwidth
1–500 MHz
Supported Application
10GbE to 100 m (IEEE 802.3an)
Rack Mounting
19-inch EIA-310, 2U
Jack Module
Panduit CJ6X88TGYL Mini-Com Cat6A
Port Angle
45° angled front face
Standard
ANSI/TIA-568.2-D / TIA-942-A

Key Features & Benefits

  • Factory-loaded Panduit CJ6X88TGYL Cat6A keystone jacks eliminate field termination variability, ensuring every port exceeds TIA-568.2-D channel performance requirements without post-installation rework.
  • 45-degree angled front face reduces patch cord bend radius stress and enables higher port density without exceeding Cat6A bend radius minimums, increasing rack space efficiency in high-density NEOM data hall environments.
  • Tested and certified to 500 MHz full bandwidth covering all Cat6A parameters (NEXT, FEXT, PSNEXT, RL, ACR-F, insertion loss) and supporting IEEE 802.3an 10GbE at 100 m channel length.
  • TIA-942-A compliant structured cabling termination panel satisfies Tier III and Tier IV data centre cabling infrastructure requirements specified by hyperscale cloud providers and carrier-neutral data centre operators in Saudi Arabia.
  • Panduit PanZone system integration with PanView iQ intelligent patch panel monitoring enables real-time port-level change detection and automated asset tracking in NEOM's smart building management infrastructure.
  • 19-inch 2U rack mount with cable management integrated label holders provides neat, auditable port identification that satisfies ARAMCO IT infrastructure labelling standards and data centre MMR documentation requirements.

Industrial Applications in Saudi Arabia

  • Horizontal cabling termination in NEOM Backbone Exchange data centre and smart-city network rooms, where TIA-942-A mandates Cat6A minimum cabling and Panduit PanZone is the specified structured cabling system.
  • Hyperscale cloud infrastructure horizontal cabling in AWS, Microsoft Azure, and Google Cloud regional data centre facilities in Riyadh under Vision 2030 Cloud First policy.
  • Enterprise LAN structured cabling in ARAMCO Dhahran Data and Analytics Centre of Excellence, where ARAMCO IT infrastructure standards specify Cat6A for all new horizontal cabling systems.
  • Office building structured cabling horizontal termination in King Abdullah Financial District Riyadh commercial towers, where LEED-certified smart building automation systems require Cat6A channel performance.
  • Hospital and healthcare facility network infrastructure in Vision 2030 healthcare expansion projects across Riyadh, Jeddah, and Mecca, where medical-grade network reliability requires TIA-568.2-D certified cabling channels.
  • Carrier-neutral colocation data centre structured cabling in Riyadh Data Centre District, where tenant SLA requirements mandate TIA-942-A compliant infrastructure with certified channel performance documentation.